Deck 8: Grounding of Specific Equipment

Full screen (f)
exit full mode
Question
The service equipment for mobile homes must be located within sight of, and not more than ____ from, the exterior wall of the mobile home it serves.

A) 15 feet
B) 20 feet
C) 30 feet
D) 40 feet
Use Space or
up arrow
down arrow
to flip the card.
Question
Studies suggest that dairy cattle tend to release more milk in response to voltage differences on exposed conductive surfaces of even a few volts.
Question
"Patient Care Vicinity" is defined as a space within a location intended for the examination and treatment of patients, extending _______ beyond the normal location of the patient bed, chair, table, treadmill, or other device that supports the patent and extending vertically to ________ above the floor.

A) 6 feet, 7-1/2 feet
B) 5 feet, 6 feet
C) 7-1/2 feet, 6 feet
D) 6 feet, 9 feet
Question
Ungrounded conductors are permitted to be marked with any color other than white, gray, or green.
Question
____________________ cable has a bare 16 AWG aluminum bonding strip installed between the conductors and the outer armor and is in intimate contact with the armor for the full length of the cable.
Question
____ locations are those that are hazardous because of the presence of combustible dust.

A) Class I
B) Class II
C) Class III
D) Class IV
Question
____ grounding paths are required to be provided to ensure one effective ground-fault current path is available and functional in patient care areas.

A) Two
B) Three
C) Four
D) Five
Question
Unlisted liquidtight flexible metal conduit may be used as an equipment grounding conductor.
Question
____ locations are those in which flammable gases or vapors are or may be present in the air in quantities sufficient to produce explosive or ignitable mixtures.

A) Class I
B) Class II
C) Class III
D) Class IV
Question
____________________ cable consists of one or more current-carrying conductors, one or more equipment grounding conductors if required, and in some cases optical fibers.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/10
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 8: Grounding of Specific Equipment
1
The service equipment for mobile homes must be located within sight of, and not more than ____ from, the exterior wall of the mobile home it serves.

A) 15 feet
B) 20 feet
C) 30 feet
D) 40 feet
C
2
Studies suggest that dairy cattle tend to release more milk in response to voltage differences on exposed conductive surfaces of even a few volts.
False
3
"Patient Care Vicinity" is defined as a space within a location intended for the examination and treatment of patients, extending _______ beyond the normal location of the patient bed, chair, table, treadmill, or other device that supports the patent and extending vertically to ________ above the floor.

A) 6 feet, 7-1/2 feet
B) 5 feet, 6 feet
C) 7-1/2 feet, 6 feet
D) 6 feet, 9 feet
A
4
Ungrounded conductors are permitted to be marked with any color other than white, gray, or green.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
5
____________________ cable has a bare 16 AWG aluminum bonding strip installed between the conductors and the outer armor and is in intimate contact with the armor for the full length of the cable.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
6
____ locations are those that are hazardous because of the presence of combustible dust.

A) Class I
B) Class II
C) Class III
D) Class IV
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
7
____ grounding paths are required to be provided to ensure one effective ground-fault current path is available and functional in patient care areas.

A) Two
B) Three
C) Four
D) Five
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
8
Unlisted liquidtight flexible metal conduit may be used as an equipment grounding conductor.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
9
____ locations are those in which flammable gases or vapors are or may be present in the air in quantities sufficient to produce explosive or ignitable mixtures.

A) Class I
B) Class II
C) Class III
D) Class IV
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
10
____________________ cable consists of one or more current-carrying conductors, one or more equipment grounding conductors if required, and in some cases optical fibers.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck