Deck 2: Hardware and Materials Used in Residential Wiring
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/53
Play
Full screen (f)
Deck 2: Hardware and Materials Used in Residential Wiring
1
Schedule 40 rigid polyvinyl chloride (Type PVC) conduit has a smaller inside diameter than Schedule 80 rigid nonmetallic PVC conduit.
False
The outside diameters are the same while the inside diameter of schedule 80 is smaller than schedule 40.
The outside diameters are the same while the inside diameter of schedule 80 is smaller than schedule 40.
2
The __________ is a scale of specified diameters and cross sections for wire sizing and is the standard wire sizing scale for the United States.
A) American Wire Gauge
B) Metric system
C) United States measuring system
D) None of the above
A) American Wire Gauge
B) Metric system
C) United States measuring system
D) None of the above
A
3
The __________ circuit conductor in a 120-volt residential branch circuit is used as the grounded conductor and returns current from the load back to the source.
A) black
B) white
C) red
D) green
A) black
B) white
C) red
D) green
B
4
The __________ is an organization that develops electrical equipment standards that all member groups follow when designing and producing electrical equipment.
A) Underwriters Laboratories
B) Canadian Standards Association
C) National Electrical Manufacturers Association
D) National Electrical Code
A) Underwriters Laboratories
B) Canadian Standards Association
C) National Electrical Manufacturers Association
D) National Electrical Code
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
5
In the American Wire Gauge system: the smaller the number, the smaller the conductor; and the larger the number, the larger the conductor.
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
6
On a GFCI receptacle, the incoming power is connected to the line terminals.
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
7
Staples are the most common item used to secure and support cables in residential wiring.
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
8
AHJs usually base their approval of electrical equipment on whether it is listed and labeled by a nationally recognized testing laboratory (NRTL).
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
9
The National Electrical Code requires Type NM cable to be secured no more than __________ inches from single-gang nonmetallic device boxes.
A) 6
B) 8
C) 10
D) 12
A) 6
B) 8
C) 10
D) 12
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
10
When using aluminum conductors, __________ size conductor must be used to carry the same amount of current as a copper conductor.
A) a smaller
B) the same
C) a larger
D) the same or larger
A) a smaller
B) the same
C) a larger
D) the same or larger
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
11
A wirenut is the most common wire connector used by electricians to splice together two or more conductors.
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
12
A low resistance path, which results in a high value of current that flows around, rather than through, a circuit is called a(n) __________ circuit.
A) open
B) short
C) grounded
D) grounding
A) open
B) short
C) grounded
D) grounding
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
13
It is the __________ who has the job of approving the electrical materials used for a residential electrical installation.
A) electrician
B) foreman
C) architect
D) authority having jurisdiction
A) electrician
B) foreman
C) architect
D) authority having jurisdiction
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
14
When nonmetallic device boxes that are 2-gang or more are used, the installed Type NM cable must be secured no more than __________ inches from the box.
A) 8
B) 10
C) 12
D) 18
A) 8
B) 10
C) 12
D) 18
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
15
Type __________ cable is used for underground installations of branch and feeder circuits.
A) NM
B) NM-B
C) SE
D) None of the above
A) NM
B) NM-B
C) SE
D) None of the above
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
16
Boxes with mounting ears are typically called new work boxes; boxes without mounting ears are referred to as old work boxes.
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
17
Which of the following conductors is the largest?
A) 8 AWG
B) 10 AWG
C) 12 AWG
D) 14 AWG
A) 8 AWG
B) 10 AWG
C) 12 AWG
D) 14 AWG
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
18
An accidental connection of a "hot" conductor and a grounded piece of equipment or the grounded conductor is called a(n) __________.
A) open circuit
B) grounding conductor
C) ground fault
D) complete circuit
A) open circuit
B) grounding conductor
C) ground fault
D) complete circuit
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
19
On a duplex receptacle, the silver screw is used to terminate the white grounded conductor of a 120-volt residential branch circuit.
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
20
Manufacturers of nonmetallic sheathed cable color code a 12/2 Type NM cable with the color orange.
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
21
The ungrounded "hot" conductor of a 120-volt residential branch circuit is terminated to the __________ terminal on a duplex receptacle.
A) brass
B) silver
C) green
D) black
A) brass
B) silver
C) green
D) black
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
22
A GFCI circuit breaker is easily recognizable by the "push-to-test" button and the __________.
A) yellow body
B) length of white wire attached to it
C) larger operating handle
D) smaller body size
A) yellow body
B) length of white wire attached to it
C) larger operating handle
D) smaller body size
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
23
Which of the following switches has ON/OFF marked on the switch handle?
A) Three way
B) Double pole
C) Four way
D) None of the above
A) Three way
B) Double pole
C) Four way
D) None of the above
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
24
The ____________________ of a conductor refers to its ability to carry current.
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
25
__________ are the most often used type of overcurrent protection device used in residential wiring.
A) Circuit breakers
B) Edison-base fuses
C) Plug fuses
D) Cartridge fuses
A) Circuit breakers
B) Edison-base fuses
C) Plug fuses
D) Cartridge fuses
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
26
A part of an electrical box that is designed to be removed so that a cable or raceway can be connected to the box is called a __________.
A) knockout
B) mounting bracket
C) cable clamp
D) plaster ear
A) knockout
B) mounting bracket
C) cable clamp
D) plaster ear
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
27
A _____ is described as a factory assembly of two or more conductors that has an overall outer sheathing that can be nonmetallic or metallic.
A) wire
B) conductor
C) cable
D) None of the above
A) wire
B) conductor
C) cable
D) None of the above
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
28
__________ plug fuses are considered nontamperable and are used in new installations requiring plug fuses.
A) Edison-base
B) Type S
C) Cartridge
D) Plug
A) Edison-base
B) Type S
C) Cartridge
D) Plug
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
29
A switch that is used on 240-volt residential branch circuits to control a load from one location is called a __________ switch.
A) single-pole
B) double-pole
C) occupancy
D) combination
A) single-pole
B) double-pole
C) occupancy
D) combination
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
30
All ____________________ boxes must be accessible after they are installed.
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
31
If a switching device has the marking CU ONLY on it, an electrician can use only __________ wire with the device.
A) copper
B) copper-clad aluminum
C) aluminum
D) Any of the above
A) copper
B) copper-clad aluminum
C) aluminum
D) Any of the above
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
32
The ______ is the device that is inserted into a receptacle to establish a connection between the conductors of the attached flexible cord and the conductors connected to the receptacle.
A) outlet
B) fuse
C) connector
D) attachment plug
A) outlet
B) fuse
C) connector
D) attachment plug
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
33
Almost all 15 or 20-amp, 125-V receptacles required in a house must be __________.
A) tamper resistant
B) terminated
C) color coded
D) self-grounding
A) tamper resistant
B) terminated
C) color coded
D) self-grounding
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
34
Romex is a trade name used by electricians to refer to __________.
A) armored cable
B) metal-clad cable
C) underground feeder cable
D) nonmetallic sheathed cable
A) armored cable
B) metal-clad cable
C) underground feeder cable
D) nonmetallic sheathed cable
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
35
A weatherproof enclosure designed to give protection from falling dirt, rain, snow, sleet, and windblown dust is classified as a _____ enclosure and will need to be installed for outside applications.
A) NEMA 1
B) NEMA 2
C) NEMA 3R
D) NEMA 12
A) NEMA 1
B) NEMA 2
C) NEMA 3R
D) NEMA 12
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
36
Type __________ cable is used for underground service entrance installations.
A) SE
B) UF
C) USE
D) NM-B
A) SE
B) UF
C) USE
D) NM-B
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
37
The NEC requires rigid metal conduit to be supported within __________ feet of each box and then no more than every __________ feet thereafter (general rule).
A) 3, 8
B) 5, 10
C) 2, 10
D) 3, 10
A) 3, 8
B) 5, 10
C) 2, 10
D) 3, 10
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
38
CO/ALR marked on a receptacle indicates that __________ conductors may be terminated to it.
A) copper
B) copper-clad aluminum
C) aluminum
D) All of the above
E) a and b only
A) copper
B) copper-clad aluminum
C) aluminum
D) All of the above
E) a and b only
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
39
When two or more electrical device boxes are joined together for the purpose of holding more than one device it is called __________.
A) fitting
B) ganging
C) sticking
D) boxing
A) fitting
B) ganging
C) sticking
D) boxing
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
40
A _____ is a type of electrical panel that contains the main disconnecting means for the residential service entrance as well as the fuses or circuit breakers used to protect circuits and equipment like electric water heaters, ranges, dryers, and lighting.
A) safety switch
B) load center
C) subpanel
D) meter socket
A) safety switch
B) load center
C) subpanel
D) meter socket
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
41
Section __________ states that only qualified electrical testing labs can test, evaluate, and then list electrical products.
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
42
A single-pole breaker is used on a circuit voltage of ____________________ volts and a two-pole breaker is used on a circuit voltage of ____________________ volts in residential wiring.
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
43
In certain locations in the United States, the AHJ may not allow nonmetallic sheathed cable in residential construction.The alternative wiring method most often used is _____________.
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
44
Explain how a product gets listed.
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
45
A(n) ____________________ is a point on the wiring system at which current is taken to supply equipment.
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
46
____________________ devices are used when more than one device is needed at one location.
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
47
Electricians often refer to Type AC cable as ____________________ cable.
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
48
____________________ is a measure of how much a fastener is being tightened and is measured in foot-pounds or inch-pounds.
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
49
Describe a situation when three-way switches are used in a residential lighting circuit.
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
50
A ____________________ is an overcurrent device that opens a circuit when a fusible link is melted away by the extreme heat caused by an overcurrent.
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
51
In residential wiring, the NEC requires a ____________________-ampere circuit breaker or fuse to be used with 12 AWG copper conductors.
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
52
_________________________ plug fuses cannot be used in new installations.
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck
53
Explain the purpose of an antioxidant in electrical wiring.
Unlock Deck
Unlock for access to all 53 flashcards in this deck.
Unlock Deck
k this deck

