Deck 9: Single-Phase Loads for Three-Phase Transformers
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
Play
Full screen (f)
Deck 9: Single-Phase Loads for Three-Phase Transformers
1
When a transformer bank must supply both three-phase and single-phase loads, the utility company will often provide an open-delta connection with one transformer ____.
A) center-tapped
B) double-tapped
C) tapped
D) double-loaded
A) center-tapped
B) double-tapped
C) tapped
D) double-loaded
A
2
High-leg voltage can be computed by increasing the single-phase center-tapped voltage value by ____.
A) 1.732
B) 3
C) 5.196
D) 9
A) 1.732
B) 3
C) 5.196
D) 9
A
3
Connecting the center tap of a primary to the center tap of a secondary will solve an unbalance problem if a wye primary is used on a three-wire system.
False
4
The type of three-phase transformer connection to use is generally determined by the ____.
A) amount of power available
B) amount of power needed
C) transformer manufacturer's specifications
D) none of the above
A) amount of power available
B) amount of power needed
C) transformer manufacturer's specifications
D) none of the above
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
Typical voltages for a three-phase transformer connection with a delta-connected primary and wye-connected secondary are 208/120 and ____.
A) 104/180
B) 416/240
C) 440/220
D) 480/277
A) 104/180
B) 416/240
C) 440/220
D) 480/277
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
In a given three-phase transformer connection with a delta-connected primary and wye-connected secondary, the secondary has been center-tapped to form a neutral conductor. The neutral conductor will ____.
A) carry the vector sum of the balanced current
B) not carry the vector sum of the balanced current
C) not carry the vector sum of the unbalanced current
D) carry the vector sum of the unbalanced current
A) carry the vector sum of the balanced current
B) not carry the vector sum of the balanced current
C) not carry the vector sum of the unbalanced current
D) carry the vector sum of the unbalanced current
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
Three-phase transformer connections are often used to supply single-phase loads, which tend to unbalance the system.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
In a delta connection where one transformer is center-tapped to form a neutral conductor, the two lines are 1800 out of phase when compared with the center tap. In the wye connection, the lines will be ____ out of phase.
A) 600
B) 900
C) 1200
D) 1800
A) 600
B) 900
C) 1200
D) 1800
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
In a three-phase transformer connection with a delta-connected primary and wye-connected secondary, the neutral conductor will not carry the vector sum of the unbalanced current.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
If incoming power is a three-phase four-wire system, a wye-connected primary can be used without problems.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
The amount of current flow in a neutral conductor will be the sum of the unbalanced load between lines L2 and L3, with the addition of the current flow in the high leg, L1. To determine the amount of neutral current, use the formula ____.
A) AN = A1 + (A2 x A3)
B) AN = A1(A2 - A3)
C) AN = A1 + (A2 - A3)
D) AN = A1(A2 + A3)
A) AN = A1 + (A2 x A3)
B) AN = A1(A2 - A3)
C) AN = A1 + (A2 - A3)
D) AN = A1(A2 + A3)
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
In a three-phase transformer connection with a delta-connected primary and wye-connected secondary, a wye-connected secondary with center tap can, under the right conditions, experience extreme unbalance problems.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
In a given transformer bank, if the three loads have been connected directly across the three-phase lines, they form a delta-connected load.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
In a given circuit, the three-phase load has a power requirement of 75 kVA, and the single-phase load requires an additional 50 kVA. Three 25-kVA transformers could be used to supply the three-phase power needed. The addition of the single-phase load, however, requires ____.
A) one of the transformers to be larger
B) two of the transformers to be larger
C) all three of the transformers to be larger
D) a fourth transformer
A) one of the transformers to be larger
B) two of the transformers to be larger
C) all three of the transformers to be larger
D) a fourth transformer
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
It is possible to use a high leg to supply power to a single-phase load.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
Assume line L1 has a current flow of 100 amps, line L2 has a current flow of 75 amps, and line L3 has a current flow of 50 amps. The amount of current flow in the neutral conductor would be ____ amps.
A) 25
B) 50
C) 75
D) 125
A) 25
B) 50
C) 75
D) 125
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
In many circuits, it is possible for the neutral conductor to carry more current than any of the three-phase lines.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
When true three-phase loads are connected to a three-phase transformer bank, there are problems in balancing the currents and voltages of the individual phases.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
In a given transformer bank, the three loads form a delta-connected load. If these three loads are intended to be used as single-phase loads, they will in all likelihood have ____.
A) a low leg
B) changing resistance values
C) unchanging vector relationships
D) constant resistance values
A) a low leg
B) changing resistance values
C) unchanging vector relationships
D) constant resistance values
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
When a line is known as a high leg, it is because the voltage between this line and the neutral conductor will be higher than the voltage between the neutral and either of the other two conductors.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck