Deck 19: Plumbing Traps

Full screen (f)
exit full mode
Question
Slip joint-type traps must be in accessible locations.
Use Space or
up arrow
down arrow
to flip the card.
Question
All floor drains require a 4" deep seal trap.
Question
The loss of trap seal caused by the back and forth movement of water sending the seal water over the crow weir is called ____.

A) momentum
B) oscillation
C) aspiration
D) capillary action
Question
Urinals are required to have integral traps.
Question
The typical trap seal is ____ deep.

A) 1inchs
B) 2 inches
C) 2inches
D) 3 inches
Question
Most codes limit trap seal depth to a maximum of ____.

A) 2 inches
B) 3 inches
C) 4 inches
D) 5 inches
Question
A plumbing trap is a device that prevents the passage of sewer gas into the structure.
Question
Traps should be one piece, without joints, for maximum trap integrity.
Question
Most of the causes of trap seal loss can be minimized or prevented by proper drainage and venting installations.
Question
____ is the loss of trap seal from negative pressure at the trap outlet.

A) Oscillation
B) Momentum
C) Capillary action
D) Siphonage
Question
A device that periodically adds water to a trap is a ____.

A) P-trap
B) hydraulic pump
C) S-trap
D) trap primer
Question
A trap primer is a device that maintains the water seal in a trap.
Question
Traps should always be smaller than the fixture outlet.
Question
Except for interceptors, the trap seal should be between ____ and ____.

A) 1 inch, 3 inches
B) 2 inches, 4 inches
C) 3 inches, 5 inches
D) 4 inches, 6 inches
Question
The ____ is the vertical distance between the top of the trap dip and the crown weir.

A) developed length
B) inlet
C) outlet
D) trap seal
Question
Evaporation is a cause of trap seal loss that cannot be prevented by correct venting.
Question
Another name for a building trap is a ____.

A) running trap
B) drum trap
C) partition trap
D) bell trap
Question
Which of the following is a permitted trap?

A) ball trap
B) partition trap
C) P-trap
D) S-trap
Question
____ is the loss of trap seal caused when water in the trap changes from liquid to vapor state and is lost from the trap.

A) Evaporation
B) Condensation
C) Aspiration
D) Oscillation
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/19
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 19: Plumbing Traps
1
Slip joint-type traps must be in accessible locations.
True
2
All floor drains require a 4" deep seal trap.
False
3
The loss of trap seal caused by the back and forth movement of water sending the seal water over the crow weir is called ____.

A) momentum
B) oscillation
C) aspiration
D) capillary action
B
4
Urinals are required to have integral traps.
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
5
The typical trap seal is ____ deep.

A) 1inchs
B) 2 inches
C) 2inches
D) 3 inches
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
6
Most codes limit trap seal depth to a maximum of ____.

A) 2 inches
B) 3 inches
C) 4 inches
D) 5 inches
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
7
A plumbing trap is a device that prevents the passage of sewer gas into the structure.
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
8
Traps should be one piece, without joints, for maximum trap integrity.
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
9
Most of the causes of trap seal loss can be minimized or prevented by proper drainage and venting installations.
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
10
____ is the loss of trap seal from negative pressure at the trap outlet.

A) Oscillation
B) Momentum
C) Capillary action
D) Siphonage
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
11
A device that periodically adds water to a trap is a ____.

A) P-trap
B) hydraulic pump
C) S-trap
D) trap primer
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
12
A trap primer is a device that maintains the water seal in a trap.
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
13
Traps should always be smaller than the fixture outlet.
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
14
Except for interceptors, the trap seal should be between ____ and ____.

A) 1 inch, 3 inches
B) 2 inches, 4 inches
C) 3 inches, 5 inches
D) 4 inches, 6 inches
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
15
The ____ is the vertical distance between the top of the trap dip and the crown weir.

A) developed length
B) inlet
C) outlet
D) trap seal
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
16
Evaporation is a cause of trap seal loss that cannot be prevented by correct venting.
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
17
Another name for a building trap is a ____.

A) running trap
B) drum trap
C) partition trap
D) bell trap
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
18
Which of the following is a permitted trap?

A) ball trap
B) partition trap
C) P-trap
D) S-trap
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
19
____ is the loss of trap seal caused when water in the trap changes from liquid to vapor state and is lost from the trap.

A) Evaporation
B) Condensation
C) Aspiration
D) Oscillation
Unlock Deck
Unlock for access to all 19 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 19 flashcards in this deck.