Deck 5: Pipings, Fittings, and Valves

Full screen (f)
exit full mode
Question
In situations where both piping and electrical wiring are in close proximity, try to keep the piping above the electrical wiring.
Use Space or
up arrow
down arrow
to flip the card.
Question
Another specialty valve widely used in hydronic systems provides the ability to isolate, flow balance, and even drain individual heat emitters.It is called a ____.

A) zone valve
B) balancing valve
C) differential pressure bypass valve
D) lockshield valve
Question
If the inlet pressure on the backflow preventer drops below the pressure in the hydronic system, springs return both check valves and the movable cartridge to their ____ positions.

A) open
B) closed
C) original
D) preset
Question
Due to thermal expansion, the greater the length of the pipe, and the greater the temperature change, the greater the change in length.
Question
In situations where good heat transfer through the walls of the pipe is desirable, ____ is unsurpassed.

A) stainless steel
B) copper
C) cross-linked polyethylene
D) composite tubing
Question
A feed water valve is used to increase the pressure of water from a domestic water distribution pipe before it enters a hydronic system.
Question
Feed water valves operate by balancing the force generated by water pressure against an internal flexible ____, with the counterforce generate by a partially compressed spring.

A) feeder
B) cavitator
C) diaphragm
D) pressurizer
Question
Fittings for copper tubing are available in either wrought copper or ____.

A) stainless steel
B) PEX
C) tempered rubber
D) cast brass
Question
The molecular structure of nonmetallic tubes such as those made of PEX or rubber compounds is such that oxygen molecules can diffuse through their tube walls and be absorbed by the fluid within.
Question
Copper tubing must be properly supported to prevent sagging or buckling.On horizontal runs of hard temper tubing, the maximum support spacing for 1/2- and 3/4-inch tube is ____ feet.

A) 2
B) 3
C) 4
D) 5
Question
In the absence of any building or mechanical codes that require otherwise, type M is the standard for copper tubing used in hydronic heating systems.
Question
Piping schematics are the road maps of hydronic system design.Unfortunately, there is no universal standard for piping symbols to which all those in the hydronics industry subscribes.
Question
In situations where several runs of piping and/or electrical conduit must be run in close proximity, a ____ system is a good option.

A) mounting rail
B) rubber liner
C) horizontal piping
D) vertical piping
Question
Hydronic heating systems, once assembled, must be filled purged of air and filled with fluid.A(n) ____ is specifically designed for this purpose.

A) purging valve
B) air deactivator valve
C) ball valve assembly
D) flow regulator valve
Question
Plumbing codes no longer allow solders containing lead to be used for domestic water service.
Question
Hydronic heating systems should never use a combination of flexible and rigid piping materials.
Question
The pressure difference between the inside and outside of the tube has a very strong effect on oxygen diffusion.
Question
A well-planned piping assembly will use the largest number of fittings possible.
Question
When long straight runs of rigid tubing are required, it may be necessary to install an expansion loop or an expansion offset to absorb the movement.Another alternative is to install an expansion ____ capable of absorbing the movement.

A) regulator
B) compensator
C) barometer
D) overflow
Question
Copper water tube is available in three wall thicknesses designated as types ____ in order of decreasing wall thickness.

A) A, B, and C
B) S, M, and L
C) K, L, and M
D) 1,2, and 3
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 5: Pipings, Fittings, and Valves
1
In situations where both piping and electrical wiring are in close proximity, try to keep the piping above the electrical wiring.
False
2
Another specialty valve widely used in hydronic systems provides the ability to isolate, flow balance, and even drain individual heat emitters.It is called a ____.

A) zone valve
B) balancing valve
C) differential pressure bypass valve
D) lockshield valve
D
3
If the inlet pressure on the backflow preventer drops below the pressure in the hydronic system, springs return both check valves and the movable cartridge to their ____ positions.

A) open
B) closed
C) original
D) preset
C
4
Due to thermal expansion, the greater the length of the pipe, and the greater the temperature change, the greater the change in length.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
In situations where good heat transfer through the walls of the pipe is desirable, ____ is unsurpassed.

A) stainless steel
B) copper
C) cross-linked polyethylene
D) composite tubing
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
A feed water valve is used to increase the pressure of water from a domestic water distribution pipe before it enters a hydronic system.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
Feed water valves operate by balancing the force generated by water pressure against an internal flexible ____, with the counterforce generate by a partially compressed spring.

A) feeder
B) cavitator
C) diaphragm
D) pressurizer
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
Fittings for copper tubing are available in either wrought copper or ____.

A) stainless steel
B) PEX
C) tempered rubber
D) cast brass
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
The molecular structure of nonmetallic tubes such as those made of PEX or rubber compounds is such that oxygen molecules can diffuse through their tube walls and be absorbed by the fluid within.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
Copper tubing must be properly supported to prevent sagging or buckling.On horizontal runs of hard temper tubing, the maximum support spacing for 1/2- and 3/4-inch tube is ____ feet.

A) 2
B) 3
C) 4
D) 5
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
In the absence of any building or mechanical codes that require otherwise, type M is the standard for copper tubing used in hydronic heating systems.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
Piping schematics are the road maps of hydronic system design.Unfortunately, there is no universal standard for piping symbols to which all those in the hydronics industry subscribes.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
In situations where several runs of piping and/or electrical conduit must be run in close proximity, a ____ system is a good option.

A) mounting rail
B) rubber liner
C) horizontal piping
D) vertical piping
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
Hydronic heating systems, once assembled, must be filled purged of air and filled with fluid.A(n) ____ is specifically designed for this purpose.

A) purging valve
B) air deactivator valve
C) ball valve assembly
D) flow regulator valve
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
Plumbing codes no longer allow solders containing lead to be used for domestic water service.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
Hydronic heating systems should never use a combination of flexible and rigid piping materials.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
The pressure difference between the inside and outside of the tube has a very strong effect on oxygen diffusion.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
A well-planned piping assembly will use the largest number of fittings possible.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
When long straight runs of rigid tubing are required, it may be necessary to install an expansion loop or an expansion offset to absorb the movement.Another alternative is to install an expansion ____ capable of absorbing the movement.

A) regulator
B) compensator
C) barometer
D) overflow
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
Copper water tube is available in three wall thicknesses designated as types ____ in order of decreasing wall thickness.

A) A, B, and C
B) S, M, and L
C) K, L, and M
D) 1,2, and 3
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 20 flashcards in this deck.