Deck 34: Wound Rotor Motors and Manual Speed Control
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/10
Play
Full screen (f)
Deck 34: Wound Rotor Motors and Manual Speed Control
1
There are two types of manual controllers, starters and regulators.
True
2
A normally closed micro-limit switch is used to sense when the manual controller is in a position such that all resistance is connected in the rotor circuit.
False
3
The phrase "wound rotor" describes the construction of the rotor.
True
4
When the rotor is installed in a motor, three leads are brought out from the rotor winding to solid conducting .
A)collector rings
B)end rings
C)slip rings
D)bearings
A)collector rings
B)end rings
C)slip rings
D)bearings
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
5
The stator windings for the three major types of three-phase motors - squirrel cage, wound rotor, and - are basically the same.
A)synchronous
B)stator
C)bearing end brackets
D)reversible
A)synchronous
B)stator
C)bearing end brackets
D)reversible
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
6
When starting wound rotor motors, the operating lever is moved to to insert the full value of resistance in the secondary circuit.
A)the first running position
B)the middle running position
C)the last running position
D)the regular running position
A)the first running position
B)the middle running position
C)the last running position
D)the regular running position
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
7
The induced current remains constant in the wound rotor motor.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
8
Drum controllers may be used in place of faceplate starters.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
9
The drum controller of a motor is separate from the resistors and is used for .
A)providing low-voltage protection
B)providing low-voltage release
C)controlling the primary magnetic switch
D)switching or controlling external resistors
A)providing low-voltage protection
B)providing low-voltage release
C)controlling the primary magnetic switch
D)switching or controlling external resistors
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
10
Sliding contact wound rotor starters and regulators control only the circuit of the motor.
A)basic
B)secondary
C)primary
D)interlocking
A)basic
B)secondary
C)primary
D)interlocking
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck