1
Large motors should be connected directly across the line on startup.
False
2
Common applications of automatic starters provide control of small machine tools, fans, pumps, oil burners, blowers, and unit heaters.
False
3
A motor may draw up to a percent current surge on starting.
A)100
B)300
C)600
D)900
A)100
B)300
C)600
D)900
C
4
When an overload relay trips, the starter mechanism unlatches, opening the contacts to stop the motor.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
5
Only one overload relay is required in either the single-pole or double-pole motor starter.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
6
Manual push-button starters are designed for infrequent starting of .
A)small AC motors
B)large DC motors
C)small DC motors
D)large AC motors
A)small AC motors
B)large DC motors
C)small DC motors
D)large AC motors
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
7
In the event of a power failure, a manual starter motor automatically restarts when the power returns.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
8
Manual push-button starters may be used to control single-phase motors rated up to .
A)5 hp
B)10 hp
C)15 hp
D)20 hp
A)5 hp
B)10 hp
C)15 hp
D)20 hp
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
9
Thermal overload units are widely used on both the fractional and integral horsepower manual starters for protection of motors from sustained electrical overcurrents that could result from overloading of the driven machine or from ____.
A)excessively low line voltage
B)excessively low power load
C)excessively high line voltage
D)excessively high power load
A)excessively low line voltage
B)excessively low power load
C)excessively high line voltage
D)excessively high power load
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
10
A manual starter is a(n) with motor overload protection.
A)pressure switch
B)limit switch
C)on-off switch
D)float switch
A)pressure switch
B)limit switch
C)on-off switch
D)float switch
Unlock Deck