Deck 28: Part Winding Motor Starters

Full screen (f)
exit full mode
Question
When selecting heater elements for the overload relays, the electrician should remember that each of the relays carries only of the motor current.

A)a fifth
B)a quarter
C)a third
D)half
Use Space or
up arrow
down arrow
to flip the card.
Question
Part winding starters are designed to be used with squirrel cage motors having two separate and parallel stator windings.
Question
Part winding starting has many applications in air-conditioning systems.
Question
Part winding motors are different in construction from standard squirrel cage motors.
Question
Part winding starters are not suitable for use with delta-wound, motors.

A)single-voltage
B)single-phase
C)dual-voltage
D)dual-purpose
Question
One disadvantage of the two-step part winding starter is that .

A)it provides closed transition starting
B)it is almost always an incremental start device
C)it uses only half-size contactors
D)it requires additional voltage reducing elements
Question
The thermal capacity of the motor limits the length of acceleration on the first winding to approximately seconds, depending on the connected load.

A)5
B)15
C)25
D)45
Question
In the part winding motor, the stator windings may be connected or delta connected, depending on the motor design.

A)A
B)M
C)Y
D)Z
Question
Part winding starters can be used in as many applications as other, more expensive types of reduced voltage starters.
Question
Part winding motor windings are intended to operate in series.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/10
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 28: Part Winding Motor Starters
1
When selecting heater elements for the overload relays, the electrician should remember that each of the relays carries only of the motor current.

A)a fifth
B)a quarter
C)a third
D)half
D
2
Part winding starters are designed to be used with squirrel cage motors having two separate and parallel stator windings.
True
3
Part winding starting has many applications in air-conditioning systems.
True
4
Part winding motors are different in construction from standard squirrel cage motors.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
5
Part winding starters are not suitable for use with delta-wound, motors.

A)single-voltage
B)single-phase
C)dual-voltage
D)dual-purpose
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
6
One disadvantage of the two-step part winding starter is that .

A)it provides closed transition starting
B)it is almost always an incremental start device
C)it uses only half-size contactors
D)it requires additional voltage reducing elements
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
7
The thermal capacity of the motor limits the length of acceleration on the first winding to approximately seconds, depending on the connected load.

A)5
B)15
C)25
D)45
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
8
In the part winding motor, the stator windings may be connected or delta connected, depending on the motor design.

A)A
B)M
C)Y
D)Z
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
9
Part winding starters can be used in as many applications as other, more expensive types of reduced voltage starters.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
10
Part winding motor windings are intended to operate in series.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 10 flashcards in this deck.