Deck 27: Autotransformer Starters

Full screen (f)
exit full mode
Question
The starting transformers are inductive loads.
Use Space or
up arrow
down arrow
to flip the card.
Question
In an autotransformer-type starter the timing for the time-delay relay that controls the transfer from the reduced voltage condition to full voltage is not adjustable.
Question
Starting compensators using a five-pole starting contactor are classified as .

A)autotransformer starters
B)open transition starters
C)secondary Resistors
D)semiautomatic Starters
Question
De-energizing the transformers while in the running position is done to conserve electrical energy.
Question
Current transformers are used on large motor starters to step down the current so that a conventional overload relay and heater may be used.

A)size
B)design
C)arrangement
D)connection
Question
Magnetic overload relays are used on large reduced voltage starters.
Question
In an autotransformer-type starter, autotransformers supply of the line voltage to the motor.

A)45%
B)55%
C)65%
D)75%
Question
Starting transformers momentarily affect the .

A)service factor
B)auxiliary equipment
C)power factor
D)motor stability
Question
Most motors are successfully started at 90 percent of line voltage.
Question
Closed transition connections are usually found on standard size and larger starters.

A)5
B)6
C)7
D)8
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/10
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 27: Autotransformer Starters
1
The starting transformers are inductive loads.
True
2
In an autotransformer-type starter the timing for the time-delay relay that controls the transfer from the reduced voltage condition to full voltage is not adjustable.
False
3
Starting compensators using a five-pole starting contactor are classified as .

A)autotransformer starters
B)open transition starters
C)secondary Resistors
D)semiautomatic Starters
B
4
De-energizing the transformers while in the running position is done to conserve electrical energy.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
5
Current transformers are used on large motor starters to step down the current so that a conventional overload relay and heater may be used.

A)size
B)design
C)arrangement
D)connection
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
6
Magnetic overload relays are used on large reduced voltage starters.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
7
In an autotransformer-type starter, autotransformers supply of the line voltage to the motor.

A)45%
B)55%
C)65%
D)75%
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
8
Starting transformers momentarily affect the .

A)service factor
B)auxiliary equipment
C)power factor
D)motor stability
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
9
Most motors are successfully started at 90 percent of line voltage.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
10
Closed transition connections are usually found on standard size and larger starters.

A)5
B)6
C)7
D)8
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 10 flashcards in this deck.