Deck 18: Three-Wire and Separate Controls

Full screen (f)
exit full mode
Question
It is necessary to restart a motor after it has been stopped by a three-wire control circuit with protection.

A)high-voltage
B)high-temperature
C)low-resistance
D)low-voltage
Use Space or
up arrow
down arrow
to flip the card.
Question
What is the first action when the start button of a three-wire control circuit is pushed?

A)The circuit is completed through the coil.
B)The contacts close.
C)The power circuit contacts to the motor close.
D)The holding contact remains off.
Question
It is sometimes desirable to operate push buttons or other control devices at some voltage higher than the motor voltage.
Question
Sirens, horns, and loud buzzers may be used in production systems to call attention to malfunctions.
Question
Pilot lights are tested frequently to ensure operation.
Question
In a three-wire control circuit, when the supply voltage returns after a failure, the circuit is re-energized.
Question
When configuring separate control wiring, the maintenance technician must ensure that the proper connections are made.
Question
A three-wire control circuit uses momentary contact, start-stop stations, and a holding circuit interlock connected with the start button to maintain the circuit.

A)in tandem
B)in parallel
C)alternately
D)in series
Question
No-voltage protection protects .

A)only the operator
B)either the operator or the equipment
C)both the operator and the equipment
D)only the equipment
Question
The operation of the overload protection the control circuit.

A)opens
B)cancels
C)closes
D)verifies
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/10
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 18: Three-Wire and Separate Controls
1
It is necessary to restart a motor after it has been stopped by a three-wire control circuit with protection.

A)high-voltage
B)high-temperature
C)low-resistance
D)low-voltage
D
2
What is the first action when the start button of a three-wire control circuit is pushed?

A)The circuit is completed through the coil.
B)The contacts close.
C)The power circuit contacts to the motor close.
D)The holding contact remains off.
A
3
It is sometimes desirable to operate push buttons or other control devices at some voltage higher than the motor voltage.
False
4
Sirens, horns, and loud buzzers may be used in production systems to call attention to malfunctions.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
5
Pilot lights are tested frequently to ensure operation.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
6
In a three-wire control circuit, when the supply voltage returns after a failure, the circuit is re-energized.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
7
When configuring separate control wiring, the maintenance technician must ensure that the proper connections are made.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
8
A three-wire control circuit uses momentary contact, start-stop stations, and a holding circuit interlock connected with the start button to maintain the circuit.

A)in tandem
B)in parallel
C)alternately
D)in series
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
9
No-voltage protection protects .

A)only the operator
B)either the operator or the equipment
C)both the operator and the equipment
D)only the equipment
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
10
The operation of the overload protection the control circuit.

A)opens
B)cancels
C)closes
D)verifies
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 10 flashcards in this deck.