Deck 14: Lamps and Ballasts for Lighting

Full screen (f)
exit full mode
Question
The ____ is defined in NEC Article 100 as the point of connection between the facilities of the serving utility and the premises wiring .

A)open delta
B)singular phase
C)service point
D)transformer
Use Space or
up arrow
down arrow
to flip the card.
Question
NEC 250.64(C)states that grounding electrode conductors generally are not permitted to be ____.

A)stranded
B)spliced
C)covered
D)integrated
Question
What liquid was used in the past in liquid-filled transformers? Is it still in use?
Question
What are the advantages of proper bonding and grounding?
Question
The two basic methods of metering are primary high-voltage metering and ____.

A)intermediate-voltage metering
B)pulsed metering
C)secondary high-voltage metering
D)low-voltage metering
Question
When and how does primary high-voltage metering take place?
Question
Utilities make up the connections on the line side and load side of their transformers according to the ____ requirements.

A)NFPA
B)NESC
C)TEK
D)UL
Question
Dry-type transformers are widely used because they are ____ than comparably rated liquid-filled transformers.

A)better dielectrics
B)better conductors
C)heavier in weight
D)lighter in weight
Question
When is ground-fault protection of equipment not required?
Question
In this country and throughout the world, ____ is(are)the common reference point for all electrical systems.

A)the atmosphere
B)a standard metal plate
C)the earth
D)individual building walls
Question
____ occur when an ungrounded "hot" conductor comes in contact with a grounded surface or grounded equipment.

A)Circuit breakings
B)Ground faults
C)Open circuits
D)Arc blasts
Question
The temperatures of an electrical arc, such as might occur on a 480/277-volt solidly grounded, wye-connected system, are ____.

A)at the boiling point of water
B)not hot enough to melt metals
C)safe for humans
D)hotter than the surface of the sun
Question
The ____ connection scheme has the advantage of being able to provide either 3-phase or 3-phase and single-phase power using only two transformers.

A)three-wire delta
B)4-wire wye
C)open delta
D)single-phase
Question
GFPE monitors are designed to sense ____ faults only.

A)phase-to-phase
B)phase-to-ground
C)3-phase
D)phase-to-neutral
Question
NEC 110.16 has a requirement for placing a notice on certain equipment to warn qualified persons of the serious hazard of ____ flash events.

A)arc
B)current
C)lightning
D)voltage
Question
GFCI protection can be attained using GFCI circuit breakers or GFCI ____.

A)switchboards
B)monitors
C)receptacles
D)panelboards
Question
NEC 230.71 permits not more than ____ disconnects to serve as the building disconnecting means.

A)6
B)10
C)14
D)18
Question
What is an effective ground-fault current path?
Question
The lower (or shorter)the ____ of the grounding path, the greater the ground-fault current.

A)length
B)elevation
C)magnetic permeability
D)impedance
Question
Today's liquid-filled transformers have their windings immersed in highly refined mineral oil (combustible), silicone fluid, edible seed oil-based dielectric coolant, or other acceptable nontoxic liquids that have ____ properties.

A)high dielectric
B)high conductance
C)low dielectric
D)photoactive
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 14: Lamps and Ballasts for Lighting
1
The ____ is defined in NEC Article 100 as the point of connection between the facilities of the serving utility and the premises wiring .

A)open delta
B)singular phase
C)service point
D)transformer
C
2
NEC 250.64(C)states that grounding electrode conductors generally are not permitted to be ____.

A)stranded
B)spliced
C)covered
D)integrated
B
3
What liquid was used in the past in liquid-filled transformers? Is it still in use?
Years ago, the most widely used liquid was askarel, a mixture of polychlorinated-biphenyls (PCBs)and trichlorobenzene-found to be highly toxic. Askarel was good for indoor installations because it was not flammable, it had excellent insulating characteristics and cooling features, and the cost was attractive. The Toxic Substance Control Act of 1976 and further regulations set forth by the Environmental Protection Agency (EPA)pretty much made askarel a thing of the past. These older transformers have either been replaced over the years or have had the askarel (the PCB liquid)removed and then replaced with noncontaminating liquids.
4
What are the advantages of proper bonding and grounding?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
The two basic methods of metering are primary high-voltage metering and ____.

A)intermediate-voltage metering
B)pulsed metering
C)secondary high-voltage metering
D)low-voltage metering
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
When and how does primary high-voltage metering take place?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
Utilities make up the connections on the line side and load side of their transformers according to the ____ requirements.

A)NFPA
B)NESC
C)TEK
D)UL
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
Dry-type transformers are widely used because they are ____ than comparably rated liquid-filled transformers.

A)better dielectrics
B)better conductors
C)heavier in weight
D)lighter in weight
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
When is ground-fault protection of equipment not required?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
In this country and throughout the world, ____ is(are)the common reference point for all electrical systems.

A)the atmosphere
B)a standard metal plate
C)the earth
D)individual building walls
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
____ occur when an ungrounded "hot" conductor comes in contact with a grounded surface or grounded equipment.

A)Circuit breakings
B)Ground faults
C)Open circuits
D)Arc blasts
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
The temperatures of an electrical arc, such as might occur on a 480/277-volt solidly grounded, wye-connected system, are ____.

A)at the boiling point of water
B)not hot enough to melt metals
C)safe for humans
D)hotter than the surface of the sun
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
The ____ connection scheme has the advantage of being able to provide either 3-phase or 3-phase and single-phase power using only two transformers.

A)three-wire delta
B)4-wire wye
C)open delta
D)single-phase
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
GFPE monitors are designed to sense ____ faults only.

A)phase-to-phase
B)phase-to-ground
C)3-phase
D)phase-to-neutral
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
NEC 110.16 has a requirement for placing a notice on certain equipment to warn qualified persons of the serious hazard of ____ flash events.

A)arc
B)current
C)lightning
D)voltage
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
GFCI protection can be attained using GFCI circuit breakers or GFCI ____.

A)switchboards
B)monitors
C)receptacles
D)panelboards
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
NEC 230.71 permits not more than ____ disconnects to serve as the building disconnecting means.

A)6
B)10
C)14
D)18
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
What is an effective ground-fault current path?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
The lower (or shorter)the ____ of the grounding path, the greater the ground-fault current.

A)length
B)elevation
C)magnetic permeability
D)impedance
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
Today's liquid-filled transformers have their windings immersed in highly refined mineral oil (combustible), silicone fluid, edible seed oil-based dielectric coolant, or other acceptable nontoxic liquids that have ____ properties.

A)high dielectric
B)high conductance
C)low dielectric
D)photoactive
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 20 flashcards in this deck.