Deck 15: Luminaires

Full screen (f)
exit full mode
Question
Describe the rules governing the disconnecting means for fluorescent luminaires.
Use Space or
up arrow
down arrow
to flip the card.
Question
Incandescent, open, or ____ lamps in lampholders; pendant luminaires; and pendant lampholders are not permitted in clothes closets.

A)recessed
B)surface-mounted
C)partially open
D)enclosed
Question
It is necessary that the illumination of a building comply with energy codes. These codes usually evaluate the illumination on the basis of the average ____ per square foot (meter)of illumination load.

A)watts
B)volt-amperes
C)lumens
D)candelas
Question
What are the requirements for multiwire branch circuits?
Question
What are the stipulations relevant to lamps in new energy conservation laws that have been enacted in some states?
Question
Type ____ luminaires are permitted to be installed in direct contact with thermal insulation.

A)IIC
B)IC
C)RC
D)XC
Question
Beginning with the 2008 edition of the National Electrical Code , the term luminaire is used exclusively. Previous editions of the NEC used the term luminaire followed by the term ____ in parentheses.

A)lamp
B)lighting source
C)fixture
D)lightbulb
Question
Most fluorescent lamps with energy savings ballasts, compact fluorescent lamps (CFLs), LEDs, and halogen lamps meet high-efficacy requirements. ____ do not.

A)Most fluorescent lamps with energy savings ballasts
B)Conventional incandescent lamps
C)Compact fluorescent lamps
D)Halogen lamps
Question
For surface-mounted and pendant-hung luminaires, support rods should be placed so that they extend about ____ in. below the finished ceiling.

A)one
B)two
C)three
D)four
Question
What are the guidelines for recessed incandescent luminaires not marked IC?
Question
A(n)____ branch circuit must supply only line-to-neutral loads if the luminaires are connected line-to-neutral.

A)multiwire
B)regular
C)irregular
D)dual-wire
Question
Recessed luminaires should be securely fastened to the ceiling framing members using bolts, screws, or ____.

A)tacks
B)rivets
C)grid elements
D)glue
Question
For fluorescent and HID luminaires, the volt-ampere allowance is based on the rating of the ____.

A)ballast
B)filament
C)tubing
D)phosphor
Question
Both incandescent and fluorescent recessed luminaires are marked with the temperature rating required for the ____ if more than 60 degrees C.

A)insulation
B)mounting box
C)supply conductors
D)ceiling
Question
Recessed incandescent luminaires not marked Type IC and those marked for installing directly in ____ must not have insulation over the top of the luminaire.

A)copper
B)aluminum
C)stainless steel
D)poured concrete
Question
The installation of luminaires, lighting outlets, and supports is covered in Article 410 of the NEC . Article 410 sets forth the basic requirements for the installation, commonly referred to as the "____."

A)light-up
B)grounding
C)pre-set
D)rough-in
Question
Why are there special requirements for clothes closets?
Question
Recessed luminaires are usually supported by ____ that are attached to the luminaires' rough-in box.

A)screws
B)nails
C)adjustable rails
D)outlet boxes
Question
Both Type THWN-2 and Type ____ conductors have an insulation temperature rating of 90 degrees Celsius and generally meet the temperature requirement for connecting luminaires.

A)THW
B)THHN
C)RHW
D)USE
Question
____ that have the light source completely enclosed are permitted in clothes closets.

A)Incandescent open lamps in lampholders
B)Pendant luminaires
C)Pendant lampholders
D)Surface-mounted or recessed fluorescent luminaires
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 15: Luminaires
1
Describe the rules governing the disconnecting means for fluorescent luminaires.
NEC 410.130(G)requires a means shall be provided for disconnecting fluorescent luminaires that have double-ended lamps and ballast(s). This requirement is for the safety of those having to work on the luminaire, such as changing out a ballast or socket. The disconnecting means is permitted to be inside or outside of the luminaire. If outside of the luminaire, it must be within sight of the luminaire.
Two-wire branch circuit: The disconnecting means is required to disconnect the ungrounded conductor supplying the ballast.
Multiwire branch circuit: The disconnecting means is required to simultaneously disconnect all conductors supplying the ballast, including the grounded conductor.
2
Incandescent, open, or ____ lamps in lampholders; pendant luminaires; and pendant lampholders are not permitted in clothes closets.

A)recessed
B)surface-mounted
C)partially open
D)enclosed
C
3
It is necessary that the illumination of a building comply with energy codes. These codes usually evaluate the illumination on the basis of the average ____ per square foot (meter)of illumination load.

A)watts
B)volt-amperes
C)lumens
D)candelas
A
4
What are the requirements for multiwire branch circuits?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
What are the stipulations relevant to lamps in new energy conservation laws that have been enacted in some states?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
Type ____ luminaires are permitted to be installed in direct contact with thermal insulation.

A)IIC
B)IC
C)RC
D)XC
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
Beginning with the 2008 edition of the National Electrical Code , the term luminaire is used exclusively. Previous editions of the NEC used the term luminaire followed by the term ____ in parentheses.

A)lamp
B)lighting source
C)fixture
D)lightbulb
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
Most fluorescent lamps with energy savings ballasts, compact fluorescent lamps (CFLs), LEDs, and halogen lamps meet high-efficacy requirements. ____ do not.

A)Most fluorescent lamps with energy savings ballasts
B)Conventional incandescent lamps
C)Compact fluorescent lamps
D)Halogen lamps
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
For surface-mounted and pendant-hung luminaires, support rods should be placed so that they extend about ____ in. below the finished ceiling.

A)one
B)two
C)three
D)four
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
What are the guidelines for recessed incandescent luminaires not marked IC?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
A(n)____ branch circuit must supply only line-to-neutral loads if the luminaires are connected line-to-neutral.

A)multiwire
B)regular
C)irregular
D)dual-wire
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
Recessed luminaires should be securely fastened to the ceiling framing members using bolts, screws, or ____.

A)tacks
B)rivets
C)grid elements
D)glue
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
For fluorescent and HID luminaires, the volt-ampere allowance is based on the rating of the ____.

A)ballast
B)filament
C)tubing
D)phosphor
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
Both incandescent and fluorescent recessed luminaires are marked with the temperature rating required for the ____ if more than 60 degrees C.

A)insulation
B)mounting box
C)supply conductors
D)ceiling
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
Recessed incandescent luminaires not marked Type IC and those marked for installing directly in ____ must not have insulation over the top of the luminaire.

A)copper
B)aluminum
C)stainless steel
D)poured concrete
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
The installation of luminaires, lighting outlets, and supports is covered in Article 410 of the NEC . Article 410 sets forth the basic requirements for the installation, commonly referred to as the "____."

A)light-up
B)grounding
C)pre-set
D)rough-in
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
Why are there special requirements for clothes closets?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
Recessed luminaires are usually supported by ____ that are attached to the luminaires' rough-in box.

A)screws
B)nails
C)adjustable rails
D)outlet boxes
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
Both Type THWN-2 and Type ____ conductors have an insulation temperature rating of 90 degrees Celsius and generally meet the temperature requirement for connecting luminaires.

A)THW
B)THHN
C)RHW
D)USE
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
____ that have the light source completely enclosed are permitted in clothes closets.

A)Incandescent open lamps in lampholders
B)Pendant luminaires
C)Pendant lampholders
D)Surface-mounted or recessed fluorescent luminaires
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 20 flashcards in this deck.