Deck 20: Low-Voltage Remote Control

Full screen (f)
exit full mode
Question
Give an overview of how a relay-based low-voltage remote-control system operates.
Use Space or
up arrow
down arrow
to flip the card.
Question
When are low-voltage remote-control systems advantageous?
Question
A low-voltage remote-control wiring system is ____ operated.

A)resistor
B)capacitor
C)transistor
D)relay
Question
If control requirements are very complex or extensive, a ____ can be installed.

A)master sequencer
B)transistor
C)conventional switch
D)double relay
Question
In a Class 2 circuit, because the power source of the circuit is limited, ____ overcurrent protection is required.

A)fuse-based
B)circuit-breaker-based
C)no
D)minimum
Question
The ____ is used in an installation where several relays are mounted in one enclosure.

A)gasket relay
B)double-throw relay
C)plug-in relay
D)standard relay
Question
What size knockout openings can relays be mounted through? What advantage does the plug-in relay have?
Question
What happens to a transformer in the case of an overload?
Question
To install color-coded cables correctly throughout an entire installation, the wires are connected to the ____, switches, master controls, and panel, like color to like color.

A)conductor
B)relays
C)circuit
D)barrier
Question
The switch used in the low-voltage remote-control system is a normally open, ____, momentary contact switch.

A)double-pole, double-throw
B)single-pole, double-throw
C)single-pole, single-throw
D)double-pole, single-throw
Question
____ identifying the switch's functions can be prepared and inserted in the switch cover.

A)Microchips
B)Directory strips
C)LEDs
D)Relays
Question
The principle of operation of a master control with rectifiers is based on the fact that a rectifier permits current in ____ direction(s).

A)only one
B)two
C)at least three
D)all
Question
The low-voltage relay is available in ____ mounting styles.

A)one
B)two
C)three
D)four
Question
The switch used in the low-voltage remote-control system is approximately ____ the size of a standard single-pole switch.

A)one-sixth
B)one-fourth
C)one-third
D)one-half
Question
Larger conductors should be used for long runs to minimize the ____.

A)current
B)voltage drop
C)transformer ratio
D)interrupt rating
Question
NEC 725.136 ( A )generally ____ Class 2 circuits in the same raceway or cable as the wiring for light and power.

A)limits the number of
B)limits the voltage of
C)prohibits
D)mandates
Question
Switches are available in up to ____-switch combinations with features such as pilot light, lighted toggle, and key operation.

A)2
B)4
C)8
D)10
Question
Most low-voltage, remote-control systems are wired with ____ AWG conductors.

A)10
B)14
C)20
D)32
Question
Give one advantage and one disadvantage to installing low-voltage wiring in a raceway.
Question
To simplify connections, the conductor color-coding combinations are red-black-white, red-black-yellow-white, red-black-yellow plus an 18 AWG common ____, red-black-blue-white, and red-black-yellow-blue-white.

A)orange
B)white
C)blue
D)green
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 20: Low-Voltage Remote Control
1
Give an overview of how a relay-based low-voltage remote-control system operates.
A low-voltage remote-control wiring system is relay operated. The relay is controlled by a low-voltage switching system and in turn controls the power circuit connected to it. The low-voltage, split-coil relay is the heart of the low-voltage remote-control system. When the "On" coil of the relay is energized, the solenoid mechanism causes the contacts to move into the "On" position to complete the power circuit. The contacts stay in this position until the "Off " coil is energized. When this occurs, the contacts are withdrawn and the power circuit is opened. The red wire is the "On" wire; the black wire is "Off "; and the blue wire is common to the transformer.
2
When are low-voltage remote-control systems advantageous?
Low-voltage remote control systems are chosen because of the number of switches required and when it is desired to have extensive control of the lighting. Low-voltage remote-control systems are available ranging from very simple to very complex. These systems can provide control from multiple locations, automatic timing control, handheld (wireless)controls, occupancy sensors ("On" when motion is detected)and unoccupancy sensors ("Off " with predetermined time-delay when no one is in the room), ceiling and wall mounted sensors, photocell control for security ("On" at dusk, "Off " at dawn), and programmable controls. Federally mandated energy codes are an energy standard for buildings, such as the joint publication ANSI/ASHRAE/IESNA 90.1, the most widely adopted energy standard
3
A low-voltage remote-control wiring system is ____ operated.

A)resistor
B)capacitor
C)transistor
D)relay
D
4
If control requirements are very complex or extensive, a ____ can be installed.

A)master sequencer
B)transistor
C)conventional switch
D)double relay
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
In a Class 2 circuit, because the power source of the circuit is limited, ____ overcurrent protection is required.

A)fuse-based
B)circuit-breaker-based
C)no
D)minimum
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
The ____ is used in an installation where several relays are mounted in one enclosure.

A)gasket relay
B)double-throw relay
C)plug-in relay
D)standard relay
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
What size knockout openings can relays be mounted through? What advantage does the plug-in relay have?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
What happens to a transformer in the case of an overload?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
To install color-coded cables correctly throughout an entire installation, the wires are connected to the ____, switches, master controls, and panel, like color to like color.

A)conductor
B)relays
C)circuit
D)barrier
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
The switch used in the low-voltage remote-control system is a normally open, ____, momentary contact switch.

A)double-pole, double-throw
B)single-pole, double-throw
C)single-pole, single-throw
D)double-pole, single-throw
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
____ identifying the switch's functions can be prepared and inserted in the switch cover.

A)Microchips
B)Directory strips
C)LEDs
D)Relays
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
The principle of operation of a master control with rectifiers is based on the fact that a rectifier permits current in ____ direction(s).

A)only one
B)two
C)at least three
D)all
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
The low-voltage relay is available in ____ mounting styles.

A)one
B)two
C)three
D)four
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
The switch used in the low-voltage remote-control system is approximately ____ the size of a standard single-pole switch.

A)one-sixth
B)one-fourth
C)one-third
D)one-half
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
Larger conductors should be used for long runs to minimize the ____.

A)current
B)voltage drop
C)transformer ratio
D)interrupt rating
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
NEC 725.136 ( A )generally ____ Class 2 circuits in the same raceway or cable as the wiring for light and power.

A)limits the number of
B)limits the voltage of
C)prohibits
D)mandates
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
Switches are available in up to ____-switch combinations with features such as pilot light, lighted toggle, and key operation.

A)2
B)4
C)8
D)10
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
Most low-voltage, remote-control systems are wired with ____ AWG conductors.

A)10
B)14
C)20
D)32
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
Give one advantage and one disadvantage to installing low-voltage wiring in a raceway.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
To simplify connections, the conductor color-coding combinations are red-black-white, red-black-yellow-white, red-black-yellow plus an 18 AWG common ____, red-black-blue-white, and red-black-yellow-blue-white.

A)orange
B)white
C)blue
D)green
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 20 flashcards in this deck.