Deck 10: Working Drawings--Upper Level

Full screen (f)
exit full mode
Question
When tabulating materials, take special note of long runs of raceway or cable and determine whether ____ is a problem. This can mean an increase in conductor and/or raceway size.

A)ampacity
B)single-phase supply
C)voltage drop
D)wiring
Use Space or
up arrow
down arrow
to flip the card.
Question
A washer-dryer rated for 4000 VA at 208Y/120 volts single-phase must have a branch-circuit ampacity of at least ____ amperes.

A)10
B)20
C)30
D)40
Question
In the computer room example in this chapter, the grounding terminal of each of the special receptacles is connected to a(n)____.

A)insulated equipment grounding conductor
B)panelboard
C)raceway
D)box
Question
​Describe basic water heater specifications and those of the beauty salon example in this chapter, and explain the role the electrical contractor in this area.
Question
​In the water heater installation example in this chapter, what is the meaning of temperature limiting?
Question
In the computer room circuits in the chapter example, three separate neutral conductors are installed to reduce the possibility of a conductor overheating from ____ currents.

A)resistive
B)nonlinear
C)lighting
D)conventional
Question
In the insurance office example in this chapter, the reception area has a(n)____ to provide a different "look" for the clients.

A)fan system
B)isolated grounding terminal
C)combination lighting system
D)water heater
Question
What steps should you take while tabulating materials to ensure the best possible outcome?
Question
​What steps have been taken to make the computer room example in this chapter compliant with good practice?
Question
A washer-dryer is rated for 4000 VA at 208Y/120 volts single-phase. The overcurrent protective device must be rated at least ____ amperes.

A)20
B)25
C)40
D)45
Question
The ____ feature of a receptacle provides protection from lightning and other severe electrical surges that may occur in the electrical system.

A)surge protection
B)grounding
C)air terminal
D)EMC
Question
In the insurance office example in this chapter, a separate, insulated-grounding conductor is installed with the feeder circuit and is connected to the neutral conductor at the service. This grounding system reduces, if not eliminates, the ____ that often is (are)present in the conventional grounding system.

A)neutral conduction
B)electrical glare
C)electromagnetic interference
D)severe electrical surges
Question
____ are available in separate units, which can be used to provide protection on any type of sensitive equipment, such as computers and printers .

A)GFCIs
B)Grounders
C)Surge protectors
D)Junction boxes
Question
Water heaters are available for commercial occupancies in many sizes and voltages, and for both single and ____ supply.

A)2-phase
B)3-phase
C)4-phase
D)5-phase
Question
NEC 422.13 requires that the branch circuit overcurrent device and conductors  for a storage-type electric water heater with a capacity of 120 gallons (450 L)or less must be sized at not less than ____ percent of the rating of the water heater .

A)80
B)100
C)125
D)150
Question
In the water heater circuit example in this chapter, the minimum size conductor, if all terminals are rated 75 degrees Celsius or higher, is ____ AWG as the ampacity in NEC Table 310.16 is 85 amperes.

A)4
B)8
C)16
D)32
Question
Three-phase circuits result in a smaller ____ than if a 1-phase circuit were installed.

A)current
B)circuit
C)conductor
D)ampacity
Question
According to NEC 422.31(B), having a disconnect switch in sight is required if a(n)____ is not readily accessible.

A)locking provision
B)ungrounded conductor
C)surge protection receptacle
D)circuit breaker
Question
In the insurance office example in this chapter, a special raceway is installed in the ____. This raceway provides for both electrical power and communications.

A)ceiling
B)two exterior walls
C)floor
D)luminaires
Question
Why is surge protection important?
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 10: Working Drawings--Upper Level
1
When tabulating materials, take special note of long runs of raceway or cable and determine whether ____ is a problem. This can mean an increase in conductor and/or raceway size.

A)ampacity
B)single-phase supply
C)voltage drop
D)wiring
C
2
A washer-dryer rated for 4000 VA at 208Y/120 volts single-phase must have a branch-circuit ampacity of at least ____ amperes.

A)10
B)20
C)30
D)40
B
3
In the computer room example in this chapter, the grounding terminal of each of the special receptacles is connected to a(n)____.

A)insulated equipment grounding conductor
B)panelboard
C)raceway
D)box
A
4
​Describe basic water heater specifications and those of the beauty salon example in this chapter, and explain the role the electrical contractor in this area.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
​In the water heater installation example in this chapter, what is the meaning of temperature limiting?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
In the computer room circuits in the chapter example, three separate neutral conductors are installed to reduce the possibility of a conductor overheating from ____ currents.

A)resistive
B)nonlinear
C)lighting
D)conventional
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
In the insurance office example in this chapter, the reception area has a(n)____ to provide a different "look" for the clients.

A)fan system
B)isolated grounding terminal
C)combination lighting system
D)water heater
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
What steps should you take while tabulating materials to ensure the best possible outcome?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
​What steps have been taken to make the computer room example in this chapter compliant with good practice?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
A washer-dryer is rated for 4000 VA at 208Y/120 volts single-phase. The overcurrent protective device must be rated at least ____ amperes.

A)20
B)25
C)40
D)45
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
The ____ feature of a receptacle provides protection from lightning and other severe electrical surges that may occur in the electrical system.

A)surge protection
B)grounding
C)air terminal
D)EMC
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
In the insurance office example in this chapter, a separate, insulated-grounding conductor is installed with the feeder circuit and is connected to the neutral conductor at the service. This grounding system reduces, if not eliminates, the ____ that often is (are)present in the conventional grounding system.

A)neutral conduction
B)electrical glare
C)electromagnetic interference
D)severe electrical surges
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
____ are available in separate units, which can be used to provide protection on any type of sensitive equipment, such as computers and printers .

A)GFCIs
B)Grounders
C)Surge protectors
D)Junction boxes
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
Water heaters are available for commercial occupancies in many sizes and voltages, and for both single and ____ supply.

A)2-phase
B)3-phase
C)4-phase
D)5-phase
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
NEC 422.13 requires that the branch circuit overcurrent device and conductors  for a storage-type electric water heater with a capacity of 120 gallons (450 L)or less must be sized at not less than ____ percent of the rating of the water heater .

A)80
B)100
C)125
D)150
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
In the water heater circuit example in this chapter, the minimum size conductor, if all terminals are rated 75 degrees Celsius or higher, is ____ AWG as the ampacity in NEC Table 310.16 is 85 amperes.

A)4
B)8
C)16
D)32
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
Three-phase circuits result in a smaller ____ than if a 1-phase circuit were installed.

A)current
B)circuit
C)conductor
D)ampacity
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
According to NEC 422.31(B), having a disconnect switch in sight is required if a(n)____ is not readily accessible.

A)locking provision
B)ungrounded conductor
C)surge protection receptacle
D)circuit breaker
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
In the insurance office example in this chapter, a special raceway is installed in the ____. This raceway provides for both electrical power and communications.

A)ceiling
B)two exterior walls
C)floor
D)luminaires
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
Why is surge protection important?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 20 flashcards in this deck.