Deck 31: Charging System Service

Full screen (f)
exit full mode
Question
7)All of the following statements are true EXCEPT:

A) after the engine starts, the control module or voltage regulator will energize the AC generator field and keep voltage at a predetermined level for about 30 seconds.
B) a defective electronic voltage regulator or computer is not a typical cause of a low charge problem.
C) the speed of an AC generator determines its output.
D) at idle, an AC generator is not capable of making maximum output.
Use Space or
up arrow
down arrow
to flip the card.
Question
2)A hot AC generator loses 75% of its rated output.
Question
4)When there is excessive AC output coming from an AC generator, a car radio sometimes makes a whining sound like a siren.
Question
8)The test MOST-Likely used to eliminate voltage regulation and fully energize the rotor is the:

A) charging system output test
B) circuit resistance test
C) voltage test
D) full-field test
Question
13)Which of the following is LEAST-Likely to cause you to replace a rotor?

A) A reading below specs indicates a shorted rotor.
B) High resistance mean connections are corroded.
C) The continuity of the rotor winding does not have any opens, shorts, or grounds.
D) Infinite resistance means the rotor is open.
Question
5)Extra resistance in the regulator circuit will cause the battery to have a lower than normal charging voltage.
Question
11)The tool MOST-Likely used to look at AC generator patterns is a(n):

A) alternator
B) lab scope
C) diode
D) regulator
Question
18)____________________ tests check for excessive resistance in the ground and insulated circuits by measuring voltage drop.
Question
6)While having a discussion, Technician A says that if you replace a battery simply because it is old, this will not solve a charging problem caused by something else. Technician B says that a new battery is the only solution. Who is correct?

A) A only
B) B only
C) Both A and B
D) Neither A nor B
Question
1)AC generator ground wires are usually braided ground straps. The condition of these wires is as important as the insulated wires because they carry the same current flow.
Question
17)The ____________________ test checks to see that the voltage regulator is energizing the rotor field and is not allowing the AC generator to overcharge.
Question
12)Which of the following statements is LEAST-Likely true?

A) Checking voltage drops as a preventive maintenance measure will catch potential problems before they fully develop.
B) A small amount of voltage drop through the fuse link, which is a smaller wire than the rest of the circuit, is normal.
C) There are no fuse links in the ground circuit, so lower voltage drop (0.1 volt) is desired.
D) When performing a voltage drop test, remember that current must not be running through the circuit.
Question
10)All of the following statements are true EXCEPT:

A) diodes must be in good condition if the AC generator is to function correctly.
B) one or more leaking diodes will decrease generator output.
C) if more than 0.2 AC volt is found in the B+ output, defective diodes are indicated.
D) diodes prevent AC from leaving the AC generator in the B+ output wire.
Question
16)The ____________________ test loads the charging system and measures its current output.
Question
14)Bad ____ are a common cause of AC generator charging problems.

A) diodes
B) ohmmeters
C) ferrules
D) rotors
Question
3)Resistance on the ground side of a regulator will raise system voltage by the amount of the voltage drop caused by the resistance.
Question
9)While having a discussion, Technician A says that the A-circuit has the regulator in the ground circuit and is the type used most often with electronic systems. Technician B says that it is the B-circuit that is configured that way. Who is correct?

A) A only
B) B only
C) Both A and B
D) Neither A nor B
Question
20)A good ____________________ will show high resistance in one direction and low resistance in the opposite direction.
Question
19)A(n) ____________________ regulator has its regulator between the positive feed (insulated side) and the field coil, which is grounded inside of the AC generator.
Question
15)A shorted ____ will have low readings in both directions.

A) diode
B) ohmmeter
C) ferrule
D) rotor
Question
25)What precautions should you take when performing an alternator test?
Question
24)What test would you perform to determine if an AC generator field is strong?
Question
23)What possible problems can be caused by a loose drive belt?
Question
21)List four charging system complaints.
Question
22)What are the steps involved in testing the charging system?
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/25
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 31: Charging System Service
1
7)All of the following statements are true EXCEPT:

A) after the engine starts, the control module or voltage regulator will energize the AC generator field and keep voltage at a predetermined level for about 30 seconds.
B) a defective electronic voltage regulator or computer is not a typical cause of a low charge problem.
C) the speed of an AC generator determines its output.
D) at idle, an AC generator is not capable of making maximum output.
B
2
2)A hot AC generator loses 75% of its rated output.
False
3
4)When there is excessive AC output coming from an AC generator, a car radio sometimes makes a whining sound like a siren.
True
4
8)The test MOST-Likely used to eliminate voltage regulation and fully energize the rotor is the:

A) charging system output test
B) circuit resistance test
C) voltage test
D) full-field test
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
5
13)Which of the following is LEAST-Likely to cause you to replace a rotor?

A) A reading below specs indicates a shorted rotor.
B) High resistance mean connections are corroded.
C) The continuity of the rotor winding does not have any opens, shorts, or grounds.
D) Infinite resistance means the rotor is open.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
6
5)Extra resistance in the regulator circuit will cause the battery to have a lower than normal charging voltage.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
7
11)The tool MOST-Likely used to look at AC generator patterns is a(n):

A) alternator
B) lab scope
C) diode
D) regulator
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
8
18)____________________ tests check for excessive resistance in the ground and insulated circuits by measuring voltage drop.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
9
6)While having a discussion, Technician A says that if you replace a battery simply because it is old, this will not solve a charging problem caused by something else. Technician B says that a new battery is the only solution. Who is correct?

A) A only
B) B only
C) Both A and B
D) Neither A nor B
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
10
1)AC generator ground wires are usually braided ground straps. The condition of these wires is as important as the insulated wires because they carry the same current flow.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
11
17)The ____________________ test checks to see that the voltage regulator is energizing the rotor field and is not allowing the AC generator to overcharge.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
12
12)Which of the following statements is LEAST-Likely true?

A) Checking voltage drops as a preventive maintenance measure will catch potential problems before they fully develop.
B) A small amount of voltage drop through the fuse link, which is a smaller wire than the rest of the circuit, is normal.
C) There are no fuse links in the ground circuit, so lower voltage drop (0.1 volt) is desired.
D) When performing a voltage drop test, remember that current must not be running through the circuit.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
13
10)All of the following statements are true EXCEPT:

A) diodes must be in good condition if the AC generator is to function correctly.
B) one or more leaking diodes will decrease generator output.
C) if more than 0.2 AC volt is found in the B+ output, defective diodes are indicated.
D) diodes prevent AC from leaving the AC generator in the B+ output wire.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
14
16)The ____________________ test loads the charging system and measures its current output.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
15
14)Bad ____ are a common cause of AC generator charging problems.

A) diodes
B) ohmmeters
C) ferrules
D) rotors
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
16
3)Resistance on the ground side of a regulator will raise system voltage by the amount of the voltage drop caused by the resistance.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
17
9)While having a discussion, Technician A says that the A-circuit has the regulator in the ground circuit and is the type used most often with electronic systems. Technician B says that it is the B-circuit that is configured that way. Who is correct?

A) A only
B) B only
C) Both A and B
D) Neither A nor B
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
18
20)A good ____________________ will show high resistance in one direction and low resistance in the opposite direction.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
19
19)A(n) ____________________ regulator has its regulator between the positive feed (insulated side) and the field coil, which is grounded inside of the AC generator.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
20
15)A shorted ____ will have low readings in both directions.

A) diode
B) ohmmeter
C) ferrule
D) rotor
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
21
25)What precautions should you take when performing an alternator test?
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
22
24)What test would you perform to determine if an AC generator field is strong?
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
23
23)What possible problems can be caused by a loose drive belt?
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
24
21)List four charging system complaints.
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
25
22)What are the steps involved in testing the charging system?
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 25 flashcards in this deck.