Deck 21: Ejector Systems

Full screen (f)
exit full mode
Question
If a sewage pump or ejector serves a single-family dwelling, it must be capable of passing a solid at least 1½ inches in diameter and have a ____ minimum discharge pipe size.

A)1½-inch
B)2-inch
C)3-inch
D)4-inch
Use Space or
up arrow
down arrow
to flip the card.
Question
If a sewage pump or ejector receives discharge from either a water closet or urinal, it must have a minimum capacity of ____ gallons per minute.

A)10
B)15
C)20
D)25
Question
The three model codes require that sewage pumps and ejectors have alarms that are audible, visual, or a combination of both for the high-level limit.
Question
The vent for a pneumatic ejector must be vented separately to the outdoors.
Question
If a sewage pump or ejector serves a commercial building, it must be capable of passing a 2-inch diameter solid and have a _____ minimum discharge pipe size.

A)2-inch
B)3-inch
C)4-inch
D)6-inch
Question
Sewage pumping stations are not prone to blockages and require little maintenance.
Question
Which of the following is NOT a factor in the selection of a pump?

A)volume of material to be displaced
B)height the material must be lifted
C)average rate of rainfall
D)power supply available
Question
_______ are installed as close to the pump as possible so that components can be easily removed from the system.

A)Caps
B)Tees
C)Elbows
D)Unions
Question
Full-ported check valves installed in sewage systems to prevent backflow are called __________.

A)RPZs
B)atmospheric-type vacuum breakers
C)double-check valve assemblies
D)backwater valves
Question
In which type of basin are the pump and fluid sensors are submerged in the waste?

A)dry
B)wet
C)septic
D)cistern
Question
Pneumatic pumps have limited passageways and can become fouled by solid objects, so rotating pumps are a practical solution.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/11
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 21: Ejector Systems
1
If a sewage pump or ejector serves a single-family dwelling, it must be capable of passing a solid at least 1½ inches in diameter and have a ____ minimum discharge pipe size.

A)1½-inch
B)2-inch
C)3-inch
D)4-inch
B
2
If a sewage pump or ejector receives discharge from either a water closet or urinal, it must have a minimum capacity of ____ gallons per minute.

A)10
B)15
C)20
D)25
C
3
The three model codes require that sewage pumps and ejectors have alarms that are audible, visual, or a combination of both for the high-level limit.
True
4
The vent for a pneumatic ejector must be vented separately to the outdoors.
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck
5
If a sewage pump or ejector serves a commercial building, it must be capable of passing a 2-inch diameter solid and have a _____ minimum discharge pipe size.

A)2-inch
B)3-inch
C)4-inch
D)6-inch
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck
6
Sewage pumping stations are not prone to blockages and require little maintenance.
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck
7
Which of the following is NOT a factor in the selection of a pump?

A)volume of material to be displaced
B)height the material must be lifted
C)average rate of rainfall
D)power supply available
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck
8
_______ are installed as close to the pump as possible so that components can be easily removed from the system.

A)Caps
B)Tees
C)Elbows
D)Unions
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck
9
Full-ported check valves installed in sewage systems to prevent backflow are called __________.

A)RPZs
B)atmospheric-type vacuum breakers
C)double-check valve assemblies
D)backwater valves
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck
10
In which type of basin are the pump and fluid sensors are submerged in the waste?

A)dry
B)wet
C)septic
D)cistern
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck
11
Pneumatic pumps have limited passageways and can become fouled by solid objects, so rotating pumps are a practical solution.
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 11 flashcards in this deck.