Deck 21: Ejector Systems
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/11
Play
Full screen (f)
Deck 21: Ejector Systems
1
If a sewage pump or ejector serves a single-family dwelling, it must be capable of passing a solid at least 1½ inches in diameter and have a ____ minimum discharge pipe size.
A)1½-inch
B)2-inch
C)3-inch
D)4-inch
A)1½-inch
B)2-inch
C)3-inch
D)4-inch
B
2
If a sewage pump or ejector receives discharge from either a water closet or urinal, it must have a minimum capacity of ____ gallons per minute.
A)10
B)15
C)20
D)25
A)10
B)15
C)20
D)25
C
3
The three model codes require that sewage pumps and ejectors have alarms that are audible, visual, or a combination of both for the high-level limit.
True
4
The vent for a pneumatic ejector must be vented separately to the outdoors.
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck
5
If a sewage pump or ejector serves a commercial building, it must be capable of passing a 2-inch diameter solid and have a _____ minimum discharge pipe size.
A)2-inch
B)3-inch
C)4-inch
D)6-inch
A)2-inch
B)3-inch
C)4-inch
D)6-inch
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck
6
Sewage pumping stations are not prone to blockages and require little maintenance.
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck
7
Which of the following is NOT a factor in the selection of a pump?
A)volume of material to be displaced
B)height the material must be lifted
C)average rate of rainfall
D)power supply available
A)volume of material to be displaced
B)height the material must be lifted
C)average rate of rainfall
D)power supply available
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck
8
_______ are installed as close to the pump as possible so that components can be easily removed from the system.
A)Caps
B)Tees
C)Elbows
D)Unions
A)Caps
B)Tees
C)Elbows
D)Unions
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck
9
Full-ported check valves installed in sewage systems to prevent backflow are called __________.
A)RPZs
B)atmospheric-type vacuum breakers
C)double-check valve assemblies
D)backwater valves
A)RPZs
B)atmospheric-type vacuum breakers
C)double-check valve assemblies
D)backwater valves
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck
10
In which type of basin are the pump and fluid sensors are submerged in the waste?
A)dry
B)wet
C)septic
D)cistern
A)dry
B)wet
C)septic
D)cistern
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck
11
Pneumatic pumps have limited passageways and can become fouled by solid objects, so rotating pumps are a practical solution.
Unlock Deck
Unlock for access to all 11 flashcards in this deck.
Unlock Deck
k this deck