Deck 10: Forced Air Heating and Alternative Heating Systems
1
Condensing furnaces rated at an efficiency of 90 percent or higher typically have a flue gas temperature of:
A)350 ° F
B)550 ° F
C)250 ° F
D)105° F
A)350 ° F
B)550 ° F
C)250 ° F
D)105° F
D
2
Lowboy furnace models are designed for outdoor installations in buildings in which interior space is not available.
False
3
Oil-fired furnace controls sense what instead of heat?
A)light
B)humidity
C)time of day
D)dirty flame
A)light
B)humidity
C)time of day
D)dirty flame
A
4
Which of the following furnace configurations were popular in areas with basements and use the unit in that location?
A)lowboy
B)upflow/highboy
C)downflow/counterflow
D)horizontal
A)lowboy
B)upflow/highboy
C)downflow/counterflow
D)horizontal
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
5
A dirty flame in an oil-fired furnace produces?
A)soot
B)reduced humidity
C)poor air quality in heated space
D)none of the above
A)soot
B)reduced humidity
C)poor air quality in heated space
D)none of the above
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
6
Which of the following is NOT a step in the startup and shutdown procedure of a modern gas furnace?
A)thermostat sends signal to control board
B)furnace runs until thermostat is satisfied
C)vent fan pressurizes vent system
D)all of the above
A)thermostat sends signal to control board
B)furnace runs until thermostat is satisfied
C)vent fan pressurizes vent system
D)all of the above
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
7
Presently, federal guidelines require manufacturers to produce fossil-fuel burning units that have an efficiency rating of at least 95 percent.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
8
Electric furnaces are far less efficient than fossil-fuel burning furnaces.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
9
Which of the fossil-fuel burning furnace units is the most efficient, based on its AFUE?
A)85
B)90
C)80
D)75
A)85
B)90
C)80
D)75
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
10
One of the most effective steps to improve the efficiency of a building is to
A)replace insulation throughout entire building
B)properly seal and insulate air conditioning duct systems
C)invest in a highly advanced system upgrade
D)add more ductwork
A)replace insulation throughout entire building
B)properly seal and insulate air conditioning duct systems
C)invest in a highly advanced system upgrade
D)add more ductwork
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
11
When determining the amount of moisture that must be added to a conditioned space, which of the following should be referenced?
A)AGA
B)AFUE
C)psychrometric chart
D)UL chart
A)AGA
B)AFUE
C)psychrometric chart
D)UL chart
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
12
Which of the following is a characteristic of electric furnaces?
A)no fuel lines
B)combustion air intake
C)ductwork
D)inefficiency
A)no fuel lines
B)combustion air intake
C)ductwork
D)inefficiency
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
13
Which furnace configuration has airflow entering on one side and exiting out of the other?
A)downflow/counterflow
B)horizontal
C)lowboy
D)package/rooftop
A)downflow/counterflow
B)horizontal
C)lowboy
D)package/rooftop
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
14
Noncondensing furnaces rated at 80 percent efficiency have a vent temperature of approximately:
A)350 ° F
B)550 ° F
C)250 ° F
D)105° F
A)350 ° F
B)550 ° F
C)250 ° F
D)105° F
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
15
Condensation forming on window sills, and other areas where outdoor air may infiltrate a space is usually a sign of what?
A)low humidity level
B)malfunctioning thermostat
C)tightly wrapped building
D)excessive humidity level
A)low humidity level
B)malfunctioning thermostat
C)tightly wrapped building
D)excessive humidity level