Deck 17: Plumbing Codes: Sanitary Drainage

Full screen (f)
exit full mode
Question
The International Plumbing Code prohibits which of the following joints and connections?

A)cement joints
B)brazed joints
C)mechanical joints
D)heat-fusion joints
Use Space or
up arrow
down arrow
to flip the card.
Question
What is the purpose of a percolation test?

A)determines acceptability of soil conditions
B)determines the DFUs for an entire building
C)tests the integrity of installed piping joints
D)tests integrity of storm drainage
Question
Which of the following is NOT a factor to be examined when operating stacks using  a code-provided table?

A)total number of fixtures discharged into each branch interval
B)velocity of discharge
C)number of branch intervals
D)branch size required for lines into the stack
Question
Which pipe material requires the use of a compression gasket for connection?

A)brass pipe
B)glass pipe
C)cast iron
D)ABS plastic pipe
Question
Pipe passing through walls should be protected by a sleeve, unless the wall is made from concrete.
Question
Which piping material is most likely to be connected using heat-fusion joints?

A)copper pipe
B)cast iron pipe
C)brass pipe
D)plastic pipe
Question
What is the term used to describe the index number that permits the combination of different fixture types to determine probable maximum load on a drainage system?

A)drainage fixture unit
B)slope unit
C)stack calculation
D)offset cost
Question
What is the minimum required design distance for a septic tank and a well?

A)25 feet
B)100 feet
C)75 feet
D)50 feet
Question
The desirable velocity of waste is about four feet per second.
Question
What is the term for the vertical portion of sanitary piping?

A)slopes
B)risers
C)subdrains
D)stacks
Question
What is the DFU recently set by the International Plumbing Code for waterless urinals?

A)1
B)1.5
C)0.5
D)2
Question
A typical water closet featuring 1.6 GPF has a DFU value of:

A)5
B)4
C)6
D)3
Question
Underground piping must be laid on a firm bed for its entire length, with the exception of galvanized steel piping.
Question
The testing of plumbing DWV systems with water or air to prove them watertight describes which plumbing test?

A)finished plumbing test
B)rough plumbing test
C)sewer test
D)existing systems test
Question
Regarding slope, the International Plumbing Code requires lines 2 ½ inches and smaller to be install at no less than how many inches per foot?

A)1/8 inch
B)1/4 inch
C)1/16 inch
D)1/2 inch
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 17: Plumbing Codes: Sanitary Drainage
1
The International Plumbing Code prohibits which of the following joints and connections?

A)cement joints
B)brazed joints
C)mechanical joints
D)heat-fusion joints
A
2
What is the purpose of a percolation test?

A)determines acceptability of soil conditions
B)determines the DFUs for an entire building
C)tests the integrity of installed piping joints
D)tests integrity of storm drainage
A
3
Which of the following is NOT a factor to be examined when operating stacks using  a code-provided table?

A)total number of fixtures discharged into each branch interval
B)velocity of discharge
C)number of branch intervals
D)branch size required for lines into the stack
B
4
Which pipe material requires the use of a compression gasket for connection?

A)brass pipe
B)glass pipe
C)cast iron
D)ABS plastic pipe
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
5
Pipe passing through walls should be protected by a sleeve, unless the wall is made from concrete.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
6
Which piping material is most likely to be connected using heat-fusion joints?

A)copper pipe
B)cast iron pipe
C)brass pipe
D)plastic pipe
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
7
What is the term used to describe the index number that permits the combination of different fixture types to determine probable maximum load on a drainage system?

A)drainage fixture unit
B)slope unit
C)stack calculation
D)offset cost
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
8
What is the minimum required design distance for a septic tank and a well?

A)25 feet
B)100 feet
C)75 feet
D)50 feet
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
9
The desirable velocity of waste is about four feet per second.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
10
What is the term for the vertical portion of sanitary piping?

A)slopes
B)risers
C)subdrains
D)stacks
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
11
What is the DFU recently set by the International Plumbing Code for waterless urinals?

A)1
B)1.5
C)0.5
D)2
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
12
A typical water closet featuring 1.6 GPF has a DFU value of:

A)5
B)4
C)6
D)3
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
13
Underground piping must be laid on a firm bed for its entire length, with the exception of galvanized steel piping.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
14
The testing of plumbing DWV systems with water or air to prove them watertight describes which plumbing test?

A)finished plumbing test
B)rough plumbing test
C)sewer test
D)existing systems test
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
15
Regarding slope, the International Plumbing Code requires lines 2 ½ inches and smaller to be install at no less than how many inches per foot?

A)1/8 inch
B)1/4 inch
C)1/16 inch
D)1/2 inch
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 15 flashcards in this deck.