Deck 15: Plumbing Codes: Water Heaters

Full screen (f)
exit full mode
Question
What is the first step in performing a draft test?

A)make sure all exterior doors and windows are closed
B)turn on all gas-fired appliances
C)shut off gas lines
D)turn on any appliances and open or close any interior door that may produce negative pressure
Use Space or
up arrow
down arrow
to flip the card.
Question
What standards do both the IPC and UPC reference when discussing combustion air for fuel-burning appliances?

A)ASSE standards
B)NFPA standards
C)ANSI standards
D)ISEA standards
Question
Which of the following is NOT a step to be taken when performing a draft test?

A)make sure all exterior doors and windows are closed
B)turn on all gas-fired appliances
C)shut off gas lines
D)turn on any appliances and open or close any interior door that may produce negative pressure
Question
Both the IPC and UPC address water heaters in Chapter 5.
Question
Regarding water heaters, how do the IPC and UPC differ?

A)UPC additionally focuses on combustion air, venting, and water heater sizes
B)UPC limits discussion to water heater location, and installation
C)IPC limits discussion to combustion air, venting, and water heater sizes
D)IPC additionally focuses on combustion air, venting, and water heater sizes
Question
To meet code, water heater drainage pans must be corrosion-resistant, and not less than how much in depth?

A)2.5 inches
B)1 inch
C)1.5 inches
D)2 inches
Question
Which of the following is NOT true about piping when considering relief valve performance?

A)it should be capable of serving multiple relief devices
B)it should not be directly connected to a drainage system
C)it should discharge to the floor, pan serving the water heater, storage tank, or outdoors
D)it should not be trapped, in the case of discharge piping
Question
During a draft test, it is important that the carbon monoxide level does not exceed:

A)40 ppm
B)45 ppm
C)30 ppm
D)35 ppm
Question
According to the 2015 IPC, in order for a relief valve to perform as intended, the piping must:

A)be trapped
B)serve multiple relief devices
C)be smaller than the diameter of the outlet of the valve served
D)not be trapped
Question
According to code, the temperature and pressure rating for hot water storage tanks shall not exceed what temperature and psi?

A)150 ° F, 210 psi
B)210 ° F, 150 psi
C)180 ° F, 170 psi
D)170 ° F, 180 psi
Question
According to IPC, what is the maximum water temperature delivered to the potable water system?

A)140 ° F
B)120 ° F
C)150 ° F
D)110 ° F
Question
When using the standard method to determine if indoor air can be used for combustion, how many cubic feet of room volume for every 1000 Btu/h firing rate of equipment must there be, minimally?

A)100
B)75
C)50
D)125
Question
Step one in a draft test is to turn on all gas-fired appliances in the equipment room.
Question
According to IPC and UPC codes, water heaters must never be installed in an attic.
Question
If the air changes per hour (ACH)are known to be less than 0.40, what method should a technician use to determine if indoor air can be used as combustion air?

A)standard method
B)known air-infiltration rate
C)cohesion method
D)combustion method
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 15: Plumbing Codes: Water Heaters
1
What is the first step in performing a draft test?

A)make sure all exterior doors and windows are closed
B)turn on all gas-fired appliances
C)shut off gas lines
D)turn on any appliances and open or close any interior door that may produce negative pressure
A
2
What standards do both the IPC and UPC reference when discussing combustion air for fuel-burning appliances?

A)ASSE standards
B)NFPA standards
C)ANSI standards
D)ISEA standards
B
3
Which of the following is NOT a step to be taken when performing a draft test?

A)make sure all exterior doors and windows are closed
B)turn on all gas-fired appliances
C)shut off gas lines
D)turn on any appliances and open or close any interior door that may produce negative pressure
C
4
Both the IPC and UPC address water heaters in Chapter 5.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
5
Regarding water heaters, how do the IPC and UPC differ?

A)UPC additionally focuses on combustion air, venting, and water heater sizes
B)UPC limits discussion to water heater location, and installation
C)IPC limits discussion to combustion air, venting, and water heater sizes
D)IPC additionally focuses on combustion air, venting, and water heater sizes
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
6
To meet code, water heater drainage pans must be corrosion-resistant, and not less than how much in depth?

A)2.5 inches
B)1 inch
C)1.5 inches
D)2 inches
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
7
Which of the following is NOT true about piping when considering relief valve performance?

A)it should be capable of serving multiple relief devices
B)it should not be directly connected to a drainage system
C)it should discharge to the floor, pan serving the water heater, storage tank, or outdoors
D)it should not be trapped, in the case of discharge piping
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
8
During a draft test, it is important that the carbon monoxide level does not exceed:

A)40 ppm
B)45 ppm
C)30 ppm
D)35 ppm
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
9
According to the 2015 IPC, in order for a relief valve to perform as intended, the piping must:

A)be trapped
B)serve multiple relief devices
C)be smaller than the diameter of the outlet of the valve served
D)not be trapped
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
10
According to code, the temperature and pressure rating for hot water storage tanks shall not exceed what temperature and psi?

A)150 ° F, 210 psi
B)210 ° F, 150 psi
C)180 ° F, 170 psi
D)170 ° F, 180 psi
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
11
According to IPC, what is the maximum water temperature delivered to the potable water system?

A)140 ° F
B)120 ° F
C)150 ° F
D)110 ° F
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
12
When using the standard method to determine if indoor air can be used for combustion, how many cubic feet of room volume for every 1000 Btu/h firing rate of equipment must there be, minimally?

A)100
B)75
C)50
D)125
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
13
Step one in a draft test is to turn on all gas-fired appliances in the equipment room.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
14
According to IPC and UPC codes, water heaters must never be installed in an attic.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
15
If the air changes per hour (ACH)are known to be less than 0.40, what method should a technician use to determine if indoor air can be used as combustion air?

A)standard method
B)known air-infiltration rate
C)cohesion method
D)combustion method
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 15 flashcards in this deck.