A pilot duty overload has a set of contacts that will open if an overload occurs in the ____________________ side of the overload.
Use Space or
up arrow
down arrow
to flip the card.
Question
What is a stack switch?
Question
There are two basic types of thermostats used in the industry today: the ____________________ thermostat and the line voltage thermostat.
Question
What is the most important element of checking line voltage thermostats?
Question
Motors are the most important loads in any heating, cooling, or refrigeration system.
Question
The ____________________ of a relay or contactor must make good direct contact when energized for the device to function properly.
Question
How is the thermal element of a thermal overload checked?
Question
The ____________________ can usually be checked by turning the motor by hand to determine if hard or rough spots exist in the rotating movement of the motor.
Question
The ____________________ is a device that will trip or open on an overload and must be manually reset.
Question
A set of burned or pitted contacts can cause a(n) ____________________ across the contacts.
Question
Normally ____________________ contacts must be checked with the device de-energized.
Question
What does the low-voltage thermostat operate?
Question
The device must be energized to check normally ____________________ contacts.
Question
____________________ electric motors will fail in three different areas: windings, centrifugal switch, and bearings.
Question
The type of motor has a significant effect on diagnosing the condition of a motor .
Question
A line voltage overload has ten or more terminals to check.
Question
A(n) ____________________ is a device used to raise or lower the incoming voltage by induction to a more usable voltage for the control system.
Question
A resistance check can be used to determine the condition of a set of contacts of a relay or contactor.
Question
How are pressure switches used on heating, cooling, and refrigeration systems?
Question
The easiest method for diagnosing bearing failure in a hermetic motor is to make a visual inspection.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 14: Troubleshooting Electric Control Devices
1
A pilot duty overload has a set of contacts that will open if an overload occurs in the ____________________ side of the overload.
line voltage
2
What is a stack switch?
The stack switch is a heat-actuated control that uses the stack temperature to indicate the presence or absence of combustion.
3
There are two basic types of thermostats used in the industry today: the ____________________ thermostat and the line voltage thermostat.
low voltage
4
What is the most important element of checking line voltage thermostats?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
Motors are the most important loads in any heating, cooling, or refrigeration system.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
The ____________________ of a relay or contactor must make good direct contact when energized for the device to function properly.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
How is the thermal element of a thermal overload checked?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
The ____________________ can usually be checked by turning the motor by hand to determine if hard or rough spots exist in the rotating movement of the motor.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
The ____________________ is a device that will trip or open on an overload and must be manually reset.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
A set of burned or pitted contacts can cause a(n) ____________________ across the contacts.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
Normally ____________________ contacts must be checked with the device de-energized.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
What does the low-voltage thermostat operate?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
The device must be energized to check normally ____________________ contacts.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
____________________ electric motors will fail in three different areas: windings, centrifugal switch, and bearings.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
The type of motor has a significant effect on diagnosing the condition of a motor .
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
A line voltage overload has ten or more terminals to check.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
A(n) ____________________ is a device used to raise or lower the incoming voltage by induction to a more usable voltage for the control system.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
A resistance check can be used to determine the condition of a set of contacts of a relay or contactor.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
How are pressure switches used on heating, cooling, and refrigeration systems?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
The easiest method for diagnosing bearing failure in a hermetic motor is to make a visual inspection.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 20 flashcards in this deck.