Deck 7: Charging Systems Charging System Testing and Service

Full screen (f)
exit full mode
Question
The delta wound stator:

A)Shares a common connection point .
B)Has each winding connected in series .
C)Does not require rectification.
D) None of these choices.
Use Space or
up arrow
down arrow
to flip the card.
Question
What type of voltage is the output at the "Bat" terminal of the AC generator?

A)DC.
B)AC.
C) Three-phase unrectified .
D) None of these choices.
Question
In a full hybrid HEV, which component is responsible for recharging the 12-volt battery from the 300-volt direct current system?

A)The battery control module .
B)The belt driven generator .
C)The DC/DC converter.
D) The LV control module .
Question
How many output diodes does an AC generator stator with three windings usually have?

A) Three .
B) Four .
C) Five .
D) Six .
Question
What components make up the AC generator field circuit?

A)Battery, stator, and diodes .
B)Battery, regulator, and stator .
C)Battery, rotor, and regulator .
D) Regulator, stator, and rotor .
Question
The magnetic field current of the AC generator is carried in the:

A)Rotor.
B)Diode trio.
C)Rectifier bridge.
D)Stator.
Question
A 100amp AC generator produces 105 amperes all the time. Full fielding it produces 105 amperes also. What does this indicate?

A)The regulator is running the AC generator full field all the time .
B)The AC generator is faulty .
C)The output wire has excessive resistance .
D) The drive belt is slipping .
Question
What device(s) is (are) used to rectify current in an AC generator?

A) Brushes .
B) Diodes .
C) Stator .
D) Rotor .
Question
The voltage induced in one conductor by one revolution of the rotor is called:

A)Three-phase.
B)Half-wave.
C)Single-phase.
D) Full-wave.
Question
What does increasing the regulator field resistance indicate?

A) More output current is desired .
B) The rotor is turning too slowly .
C) Less output current is desired .
D) B+ sensing voltage is lower than specified .
Question
The amount of voltage output of the AC generator is related to:

A)Field strength.
B)Stator speed.
C)Number of rotor segments.
D) All of these choices.
Question
Where is the output of an AC generator created?

A) The stator .
B) The rotor .
C) The housing .
D) The brushes.
Question
In a full hybrid HEV, which component is responsible for recharging the 12 volt battery from the 300 volt direct current system?

A) The battery control module.
B) The belt driven generator .
C) The DC/DC converter .
D) The LV control module .
Question
Why should an AC generator never be operated open-circuit?

A)It could overcharge the battery .
B)It could burn out electronic components .
C) It could ruin the AC generator stator .
D) None of these choices.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/14
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 7: Charging Systems Charging System Testing and Service
1
The delta wound stator:

A)Shares a common connection point .
B)Has each winding connected in series .
C)Does not require rectification.
D) None of these choices.
D
2
What type of voltage is the output at the "Bat" terminal of the AC generator?

A)DC.
B)AC.
C) Three-phase unrectified .
D) None of these choices.
A
3
In a full hybrid HEV, which component is responsible for recharging the 12-volt battery from the 300-volt direct current system?

A)The battery control module .
B)The belt driven generator .
C)The DC/DC converter.
D) The LV control module .
C
4
How many output diodes does an AC generator stator with three windings usually have?

A) Three .
B) Four .
C) Five .
D) Six .
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
5
What components make up the AC generator field circuit?

A)Battery, stator, and diodes .
B)Battery, regulator, and stator .
C)Battery, rotor, and regulator .
D) Regulator, stator, and rotor .
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
6
The magnetic field current of the AC generator is carried in the:

A)Rotor.
B)Diode trio.
C)Rectifier bridge.
D)Stator.
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
7
A 100amp AC generator produces 105 amperes all the time. Full fielding it produces 105 amperes also. What does this indicate?

A)The regulator is running the AC generator full field all the time .
B)The AC generator is faulty .
C)The output wire has excessive resistance .
D) The drive belt is slipping .
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
8
What device(s) is (are) used to rectify current in an AC generator?

A) Brushes .
B) Diodes .
C) Stator .
D) Rotor .
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
9
The voltage induced in one conductor by one revolution of the rotor is called:

A)Three-phase.
B)Half-wave.
C)Single-phase.
D) Full-wave.
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
10
What does increasing the regulator field resistance indicate?

A) More output current is desired .
B) The rotor is turning too slowly .
C) Less output current is desired .
D) B+ sensing voltage is lower than specified .
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
11
The amount of voltage output of the AC generator is related to:

A)Field strength.
B)Stator speed.
C)Number of rotor segments.
D) All of these choices.
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
12
Where is the output of an AC generator created?

A) The stator .
B) The rotor .
C) The housing .
D) The brushes.
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
13
In a full hybrid HEV, which component is responsible for recharging the 12 volt battery from the 300 volt direct current system?

A) The battery control module.
B) The belt driven generator .
C) The DC/DC converter .
D) The LV control module .
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
14
Why should an AC generator never be operated open-circuit?

A)It could overcharge the battery .
B)It could burn out electronic components .
C) It could ruin the AC generator stator .
D) None of these choices.
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 14 flashcards in this deck.