Deck 38: Installation

Full screen (f)
exit full mode
Question
When hanging a horizontal air handler, it should be pitched toward the drain port for proper condensate removal.
Use Space or
up arrow
down arrow
to flip the card.
Question
When the length of quick-connect precharged line sets is altered, the charge will not normally have to be altered.
Question
Application of acoustical lining to the interior of a duct is accomplished by using tabs, glue, or both.
Question
An auxiliary drain pan under the unit is recommended when the evaporator is installed ____.

A) near a dry well
B) at the end of the house
C) above the conditioned space
D) next to a driveway or patio
Question
A boot in a duct system is a fitting used ____.

A) at the plenum
B) between the trunk duct and the branch duct
C) between the branch duct and the supply register
D) to eliminate vibration between the unit and the duct
Question
What two fasteners are used with fiberglass ductboard?

A) "S" fasteners (slips) and drive clips.
B) Staples and tape.
C) Self-tapping screws and draw bands.
D) Tabs and adhesives.
Question
When installing a split air-conditioning system with a remote condensing unit, the line set may be altered if the standard length was incorrect for installation.
Question
____ used at the end of a metal duct run will help reduce any noise that may be traveling through the duct.

A) Fiberglass ductboard
B) Aluminum duct
C) Insulated metal duct
D) Flexible duct
Question
A good way to fasten acoustical lining to the inside of sheet metal duct is to use ____.

A) "S" fasteners (slips) and drive clips
B) staples and tape
C) self-tapping screws and draw bands
D) tabs and adhesives
Question
The sun shining on the panels and coils of the condensing section will lower the efficiency of the unit.
Question
Once the power has been connected to the condensing unit of a package air conditioner, it is a good idea to start the compressor immediately to make certain it runs.
Question
One drawback of using custom made, pre-fabricated duct sections is that ____.

A) if the measuring was not done correctly, the job may not go together
B) altering a duct section at the job site results in lost time
C) altering a duct section at the job site is extremely cost-ineffective
D) All of the above.
Question
Power to the control transformer is controlled by the conditioned area thermostat.
Question
What fastener is commonly used with round flexible duct?

A) "S" fasteners (slips) and drive clips.
B) Staples and tape.
C) Self-tapping screws.
D) Tabs and adhesives.
Question
After refrigerant lines have been installed, they should be evacuated to a(n) ____ vacuum.

A) average
B) low
C) moderate
D) deep
Question
What two fasteners are used with sheet metal square and rectangular duct?

A) "S" fasteners (slips) and drive clips.
B) Staples and tape.
C) Self-tapping screws and draw bands.
D) Tabs and adhesives.
Question
When removing the rubber plugs from a line set, the hiss indicates that the tubing is not leaking.
Question
One purpose of a flexible duct connector in a duct system is to reduce the transmission of noise and vibration.
Question
A fitting used to change the size of a square or rectangular duct is called a(n) ____________________.
Question
A trap in the condensate line prevents ____.

A) air from being drawn up into unit from the end of the drain
B) foreign particles from being pulled into the condenser
C) the pump turning on if the float fails
D) Both a and b.
Question
Before a system is evacuated, all piping should be filled with nitrogen and a small amount of refrigerant, in order to be ___________________ checked.
Question
The typical gauge wire that is used in low voltage control circuits is ____________________ gauge.
Question
Even though the cooling wire runs from the thermostat to the air handler, it actually just continues on to the condensing unit. Why isn't the cooling wire run directly from the thermostat to the condensing unit?
Question
What materials are normally used in air-conditioning duct systems?
Question
Explain service accessibility.
Question
Why is it necessary that the crankcase heater heats the compressor crankcase before starting the compressor?
Question
How much does sunshine affect the operation of a condensing unit?
Question
A split central air-conditioning system is installed with the control transformer located in the attic-hung air handler and the condensing unit located outside. The low voltage wire from the thermostat is run to the ____________________.
Question
The line voltage for a system is normally installed by whom?
Question
What does a technician do before altering a precharged line set?
Question
A round to rectangular fitting is called a(n) ____________________.
Question
If a duct system has large air leaks at the connections, what can be used to seal them up?
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/32
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 38: Installation
1
When hanging a horizontal air handler, it should be pitched toward the drain port for proper condensate removal.
False
2
When the length of quick-connect precharged line sets is altered, the charge will not normally have to be altered.
False
3
Application of acoustical lining to the interior of a duct is accomplished by using tabs, glue, or both.
True
4
An auxiliary drain pan under the unit is recommended when the evaporator is installed ____.

A) near a dry well
B) at the end of the house
C) above the conditioned space
D) next to a driveway or patio
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
5
A boot in a duct system is a fitting used ____.

A) at the plenum
B) between the trunk duct and the branch duct
C) between the branch duct and the supply register
D) to eliminate vibration between the unit and the duct
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
6
What two fasteners are used with fiberglass ductboard?

A) "S" fasteners (slips) and drive clips.
B) Staples and tape.
C) Self-tapping screws and draw bands.
D) Tabs and adhesives.
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
7
When installing a split air-conditioning system with a remote condensing unit, the line set may be altered if the standard length was incorrect for installation.
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
8
____ used at the end of a metal duct run will help reduce any noise that may be traveling through the duct.

A) Fiberglass ductboard
B) Aluminum duct
C) Insulated metal duct
D) Flexible duct
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
9
A good way to fasten acoustical lining to the inside of sheet metal duct is to use ____.

A) "S" fasteners (slips) and drive clips
B) staples and tape
C) self-tapping screws and draw bands
D) tabs and adhesives
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
10
The sun shining on the panels and coils of the condensing section will lower the efficiency of the unit.
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
11
Once the power has been connected to the condensing unit of a package air conditioner, it is a good idea to start the compressor immediately to make certain it runs.
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
12
One drawback of using custom made, pre-fabricated duct sections is that ____.

A) if the measuring was not done correctly, the job may not go together
B) altering a duct section at the job site results in lost time
C) altering a duct section at the job site is extremely cost-ineffective
D) All of the above.
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
13
Power to the control transformer is controlled by the conditioned area thermostat.
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
14
What fastener is commonly used with round flexible duct?

A) "S" fasteners (slips) and drive clips.
B) Staples and tape.
C) Self-tapping screws.
D) Tabs and adhesives.
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
15
After refrigerant lines have been installed, they should be evacuated to a(n) ____ vacuum.

A) average
B) low
C) moderate
D) deep
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
16
What two fasteners are used with sheet metal square and rectangular duct?

A) "S" fasteners (slips) and drive clips.
B) Staples and tape.
C) Self-tapping screws and draw bands.
D) Tabs and adhesives.
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
17
When removing the rubber plugs from a line set, the hiss indicates that the tubing is not leaking.
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
18
One purpose of a flexible duct connector in a duct system is to reduce the transmission of noise and vibration.
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
19
A fitting used to change the size of a square or rectangular duct is called a(n) ____________________.
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
20
A trap in the condensate line prevents ____.

A) air from being drawn up into unit from the end of the drain
B) foreign particles from being pulled into the condenser
C) the pump turning on if the float fails
D) Both a and b.
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
21
Before a system is evacuated, all piping should be filled with nitrogen and a small amount of refrigerant, in order to be ___________________ checked.
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
22
The typical gauge wire that is used in low voltage control circuits is ____________________ gauge.
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
23
Even though the cooling wire runs from the thermostat to the air handler, it actually just continues on to the condensing unit. Why isn't the cooling wire run directly from the thermostat to the condensing unit?
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
24
What materials are normally used in air-conditioning duct systems?
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
25
Explain service accessibility.
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
26
Why is it necessary that the crankcase heater heats the compressor crankcase before starting the compressor?
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
27
How much does sunshine affect the operation of a condensing unit?
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
28
A split central air-conditioning system is installed with the control transformer located in the attic-hung air handler and the condensing unit located outside. The low voltage wire from the thermostat is run to the ____________________.
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
29
The line voltage for a system is normally installed by whom?
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
30
What does a technician do before altering a precharged line set?
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
31
A round to rectangular fitting is called a(n) ____________________.
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
32
If a duct system has large air leaks at the connections, what can be used to seal them up?
Unlock Deck
Unlock for access to all 32 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 32 flashcards in this deck.