Deck 46: Room Air Conditioners
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/34
Play
Full screen (f)
Deck 46: Room Air Conditioners
1
A heat-pump-style room air conditioner has all the major components of a cooling-only unit with the addition of a ____.
A) 3-way valve
B) 4-way valve
C) quarter-turn valve
D) line-tap valve
A) 3-way valve
B) 4-way valve
C) quarter-turn valve
D) line-tap valve
B
2
Electrical service for a room unit may also involve the thermostat and the power cord.
True
3
The round piece fastened to the outer tips of the condenser fan blade is called the ____.
A) blade brace
B) dip ring
C) air spreader
D) slinger ring
A) blade brace
B) dip ring
C) air spreader
D) slinger ring
D
4
Combination cooling and heating units may include electric strip heaters or be of the heat-pump style.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
5
The addition of a window air conditioner of ____ size may overload a circuit.
A) medium
B) any
C) small
D) large
A) medium
B) any
C) small
D) large
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
6
The window unit must be installed in such a manner that air can circulate across the ____ and not recirculate or high head pressures will result.
A) condenser
B) evaporator
C) compressor
D) metering device
A) condenser
B) evaporator
C) compressor
D) metering device
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
7
When servicing an R-410A window air conditioner, adjust the airflow across the condenser until the head pressure reaches ____.
A) 360 psig
B) 400 psig
C) 420 psig
D) 460 psig
A) 360 psig
B) 400 psig
C) 420 psig
D) 460 psig
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
8
Cooling-only window air conditioners range in size from about 4,000 Btu/h to 24,000 Btu/h.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
9
If a window air conditioner is installed with an inward pitch, the condensate could leak into the room.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
10
Cooling-only room air conditioners are marketed in ____ Btu/h capacities.
A) 1,000 to 15,000
B) 3,000 to 20,000
C) 4,000 to 24,000
D) 5,000 to 30,000
A) 1,000 to 15,000
B) 3,000 to 20,000
C) 4,000 to 24,000
D) 5,000 to 30,000
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
11
To ensure correct direction of refrigerant flow in heat-pump-style room air conditioners, ____ are included in the unit.
A) filter drivers
B) globe valves
C) quarter-turn valves
D) check valves
A) filter drivers
B) globe valves
C) quarter-turn valves
D) check valves
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
12
The most common refrigerant used in older room air conditioners is ____.
A) R-12
B) R-22
C) R-410A
D) R-500
A) R-12
B) R-22
C) R-410A
D) R-500
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
13
The evaporator of a window air conditioner should operate ____.
A) far below freezing temperature
B) far above freezing temperature
C) just above freezing temperature
D) at 15°F
A) far below freezing temperature
B) far above freezing temperature
C) just above freezing temperature
D) at 15°F
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
14
The compressor for room units is a typical hermetically sealed air-conditioning compressor.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
15
The most common refrigerant used in newly manufactured room air conditioners is ____.
A) R-12
B) R-22
C) R-500
D) R-410A
A) R-12
B) R-22
C) R-500
D) R-410A
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
16
The condensate off the evaporator coil in a room air conditioner is generally disposed of by ____.
A) draining to the outside soil
B) piping to a storm drain
C) draining to the slinger system of the fan
D) draining to a holding tank
A) draining to the outside soil
B) piping to a storm drain
C) draining to the slinger system of the fan
D) draining to a holding tank
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
17
All 230-V power supplies use the same style plug.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
18
The evaporator typically operates _____ the dew point temperature of the room air.
A) much lower than
B) much higher than
C) below
D) above
A) much lower than
B) much higher than
C) below
D) above
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
19
Heat exchange between the capillary tube and the suction line is typically found on window air conditioners.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
20
The term used to reference the assembly of all the components that make up the air-conditioning system is ____.
A) casement
B) sleeve
C) chassis
D) wrap-around
A) casement
B) sleeve
C) chassis
D) wrap-around
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
21
The thermostat for room units is usually mounted with the control knob in the control center and the remote bulb in the vicinity of the return air.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
22
How many air moving motors do cooling-only room air conditioners usually have?
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
23
Central air conditioning systems operate with a design evaporator saturation temperature of about ____________________ºF.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
24
What are the two advantages of draining the condensed moisture to the slinger system on the condenser?
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
25
The metering device in a modern room air conditioner is a(n) ____________________.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
26
Some cooling-only window air conditioners are equipped with energy-saver switches. What is their purpose?
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
27
In a heat-pump-style room air conditioner in the heating cycle, the indoor coil acts as the ____________________.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
28
Where is the thermostat's sensing bulb located on a window air conditioner?
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
29
Why may the window unit installation be considered temporary and the through-the-wall unit considered permanent?
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
30
Why do room air conditioners ice up easier than central air-conditioning systems?
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
31
An extremely dirty air filter can cause the window air conditioner to operate at low suction pressures.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
32
What are some of the concerns with the heat-pump-style room air conditioner?
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
33
Window installation of room units are for either double-hung or ____________________ windows.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
34
In a heat-pump room air conditioner in the cooling cycle, the indoor coil acts as the ____________________.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck

