Deck 19: Hazardous Locations
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
Play
Full screen (f)
Deck 19: Hazardous Locations
1
Some types of explosionproof enclosures are designed to be drilled and tapped in the field. When this is done, at least ____ full threads should be engaged between the conduit and the enclosure.
A) three
B) five
C) seven
D) 11
A) three
B) five
C) seven
D) 11
B
2
____ are used to minimize the passage of gas and to prevent the passage of flame through the conduit.
A) Outlet boxes
B) Seals
C) Fibers
D) Vacuums
A) Outlet boxes
B) Seals
C) Fibers
D) Vacuums
B
3
A Group A atmosphere contains ____.
A) hydrogen
B) 2-butanol
C) butadiene
D) acetylene
A) hydrogen
B) 2-butanol
C) butadiene
D) acetylene
D
4
If it is necessary to remove a substance from the surface of an explosionproof enclosure that cannot be cleaned with solvent, use ____.
A) a chisel
B) a putty knife
C) sandpaper
D) a fine steel wool
A) a chisel
B) a putty knife
C) sandpaper
D) a fine steel wool
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
If a stem is longer than ____ in., lateral braces must be placed within 12 in. (300 mm) of the luminaire, or an explosionproof flexible coupling must be used within 12 in. (300 mm) of the junction box.
A) 6
B) 10
C) 12
D) 14
A) 6
B) 10
C) 12
D) 14
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
What conditions are required for flexible cords and attachment plugs to be used in hazardous areas?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
What do Group C and D atmospheres encompass?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
When horizontal seals are installed, ____ fiber dams must be used.
A) two
B) three
C) four
D) five
A) two
B) three
C) four
D) five
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
What is the hazard level of an aircraft hangar?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
Intrinsically safe equipment and circuits operate ____.
A) without electricity
B) at low power levels
C) at high voltage
D) at high current
A) without electricity
B) at low power levels
C) at high voltage
D) at high current
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
When circuit breakers are installed in Class I locations, they must be ____.
A) dustproof
B) dust-ignitionproof
C) explosionproof
D) waterproof
A) dustproof
B) dust-ignitionproof
C) explosionproof
D) waterproof
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
The ____ rating indicates the maximum operating temperature of a luminaire.
A) T
B) MOT
C) MT
D) TEMP
A) T
B) MOT
C) MT
D) TEMP
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
In general, the floor area of a garage, up to a level of 18 in. (450 mm) above the floor, is considered to be a ____ location.
A) Class I, Division 1
B) Class I, Division 2
C) Class II, Division 1
D) Class II, Division 2
A) Class I, Division 1
B) Class I, Division 2
C) Class II, Division 1
D) Class II, Division 2
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
What is the difference between Division 1 and Division 2 hazardous locations?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
Class III locations are areas that contain combustible ____.
A) dusts
B) gases
C) fibers
D) vapors
A) dusts
B) gases
C) fibers
D) vapors
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
Describe the mating surfaces of explosionproof equipment.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
To help prevent condensation, some vertical seals are designed with ____.
A) fiber dams
B) conductors
C) drain plugs
D) horizontal seals
A) fiber dams
B) conductors
C) drain plugs
D) horizontal seals
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
A Group E atmosphere contains ____.
A) combustible metal dusts
B) carbonaceous dusts
C) acetaldehyde
D) propylene oxide
A) combustible metal dusts
B) carbonaceous dusts
C) acetaldehyde
D) propylene oxide
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
____ locations are considered to be the most hazardous.
A) Class I, Division 1
B) Class I, Division 2
C) Class II, Division 1
D) Class II, Division 2
A) Class I, Division 1
B) Class I, Division 2
C) Class II, Division 1
D) Class II, Division 2
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
As a general rule, equipment installed in a Class II location must be ____.
A) dustproof
B) explosionproof
C) waterproof
D) dust-ignitionproof
A) dustproof
B) explosionproof
C) waterproof
D) dust-ignitionproof
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck