Deck 10: Electrical Box Installation
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/41
Play
Full screen (f)
Deck 10: Electrical Box Installation
1
When computing box fill, each 14 AWG lighting fixture wire counts as one conductor.
True
2
The NEC requires all device boxes installed to meet the requirements of Section 210.52 to be no higher than 5 1/2 feet but has no other rules regarding the mounting height of electrical boxes for switches or receptacles in residential wiring.
True
3
Nonmetallic device boxes used in residential wiring typically have both their cubic inch volume and the maximum number of 14, 12, and 10 AWG conductors marked on the box.
True
4
When computing box fill, which of the following would count as one conductor?
A) Single-pole switch
B) External cable clamp
C) Duplex receptacle
D) None of the above
A) Single-pole switch
B) External cable clamp
C) Duplex receptacle
D) None of the above
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
5
A wire that has its origin inside a device box and does not leave the device box, such as a pigtail, counts as one conductor when computing box fill.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
6
Lighting fixtures that weigh more than __________ pounds must be supported independently of the device box.
A) 35
B) 40
C) 50
D) 55
A) 35
B) 40
C) 50
D) 55
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
7
The NEC requires that device boxes be installed so that all nails or screws are outside the box.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
8
The size of the opening of a standard metal device box used to mount a switch or receptacle in a wall is __________.
A) 2" * 4"
B) 2" * 2"
C) 4" * 4"
D) 3" * 2"
A) 2" * 4"
B) 2" * 2"
C) 4" * 4"
D) 3" * 2"
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
9
A device or outlet box can also be used as a junction box.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
10
The number of conductors permitted in a box is determined by __________.
A) the area of the box
B) the perimeter of the box
C) the volume of the box
D) Underwriters Laboratories
A) the area of the box
B) the perimeter of the box
C) the volume of the box
D) Underwriters Laboratories
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
11
In residential wiring, which of the following is an area where Handy (Utility)boxes would not be used?
A) Unfinished basements
B) Unfinished garages
C) Outdoors
D) Storage buildings
A) Unfinished basements
B) Unfinished garages
C) Outdoors
D) Storage buildings
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
12
The NEC requires electrical boxes to be mounted so that they are flush with the finished surface of walls made of both combustible and noncombustible materials.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
13
Nonmetallic electrical boxes used for lighting outlets in residential wiring are __________.
A) rectangular
B) square
C) octagonal
D) round
A) rectangular
B) square
C) octagonal
D) round
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
14
Ceiling suspended paddle fans that weigh more than __________ pounds may be supported by an outlet box as long as the box has the maximum weight it can support marked on it.
A) 35
B) 40
C) 50
D) 55
A) 35
B) 40
C) 50
D) 55
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
15
In walls or ceilings made of noncombustible materials, electrical boxes must be mounted so they are __________ the finished wall surface.
A) set back no more than 1/8" from
B) set back no more than 1/4" from
C) set back no more than 1/2" from
D) flush with
A) set back no more than 1/8" from
B) set back no more than 1/4" from
C) set back no more than 1/2" from
D) flush with
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
16
In which of the following NEC Tables would you find information on box fill?
A) Table 220.12
B) Table 314.16(A)
C) Table 250.66
D) Table 8 in Chapter 9
A) Table 220.12
B) Table 314.16(A)
C) Table 250.66
D) Table 8 in Chapter 9
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
17
When computing box fill for a box that has more than one size of conductor in it, a 12 AWG conductor counts as __________ cubic inches.
A) 1.75
B) 2.0
C) 2.25
D) 2.5
A) 1.75
B) 2.0
C) 2.25
D) 2.5
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
18
When installing electrical boxes above a dropped ceiling, it is OK to have the boxes supported by the same wires that hold up the dropped ceiling.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
19
__________ have no ears on them and are designed to be attached directly to building framing members.
A) Old work boxes
B) New work boxes
C) Re-model boxes
D) Fill boxes
A) Old work boxes
B) New work boxes
C) Re-model boxes
D) Fill boxes
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
20
Which of the following would count as two conductors when computing box fill?
A) Single-pole switch
B) Duplex Receptacle
C) GFCI Receptacle
D) All of the above
A) Single-pole switch
B) Duplex Receptacle
C) GFCI Receptacle
D) All of the above
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
21
For each looped or coiled, unbroken length of conductor at least 12 inches long which passes through a box without splice or connection, the volume allowance is __________ of the actual conductor size.
A) 1
B) 2
C) 3
D) not counted
A) 1
B) 2
C) 3
D) not counted
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
22
A 4" x 1 1/2" square box can hold a maximum of __________ 14 AWG conductors.
A) 12
B) 10
C) 15
D) 9
A) 12
B) 10
C) 15
D) 9
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
23
Explain what Madison Hold-Its are used for.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
24
When computing box fill, 3 - 12 AWG conductors and 2 - 14 AWG conductors would total __________ cubic inches.
A) 10.00
B) 10.25
C) 10.50
D) 10.75
A) 10.00
B) 10.25
C) 10.50
D) 10.75
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
25
When computing box fill, all internal clamps count as ____________________ conductor(s) of the largest conductor in the box.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
26
The actual volume for a 4" x 1 1/2" square box with a 21 cubic inch volume with a single gang 4" x 3/4" raised plaster ring with a marked volume of 4.5 cubic inches attached to it is:
A) 18 cubic inches
B) 21 cubic inches
C) 25.5 cubic inches
D) 30.5 cubic inches
A) 18 cubic inches
B) 21 cubic inches
C) 25.5 cubic inches
D) 30.5 cubic inches
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
27
A ____________________ saw is used to cut holes in lath and plaster or sheetrock walls when installing old work electrical boxes.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
28
A plastic nail-on single-gang device box has a volume of 24 cubic inches. What is the maximum number of 14 AWG conductors it can hold?
A) 12
B) 14
C) 18
D) 24
A) 12
B) 14
C) 18
D) 24
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
29
Explain why lighting outlet boxes are permitted to be used as junction boxes.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
30
Each unspliced conductor that is less than 12 inches long running through a box is counted as ____________________ conductor when computing box fill.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
31
A 3" x 2" 3 1/2" metal device box can hold a maximum of __________ 12 AWG conductors.
A) 10
B) 9
C) 8
D) 7
A) 10
B) 9
C) 8
D) 7
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
32
When computing box fill, three ground wires are counted as ____________________ conductor(s) of the largest conductor in the box.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
33
Explain what 'ganging' electrical boxes means.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
34
Explain when an electrician would use an adjustable bar hanger to mount a ceiling electrical box.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
35
____________________ means capable of being removed or exposed without damaging the building structure or finish or not permanently closed in by the structure or finish of the building.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
36
A metal 4" square box has ten 12 AWG conductors, four 12 AWG grounding conductors, and four external clamps. What is the minimum size 4" square box you could use?
A) 4 * 1 1/4
B) 4 * 1 1/2
C) 4 * 2 1/8
D) 4 11/16 * 1 1/4
A) 4 * 1 1/4
B) 4 * 1 1/2
C) 4 * 2 1/8
D) 4 11/16 * 1 1/4
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
37
A metal device box has two 14 AWG conductors, one 14 AWG grounding conductor, two internal clamps, and a duplex receptacle. What is the minimum size metal device box you could use?
A) 3 * 2 * 2
B) 3 * 2 * 2 1/4
C) 3 * 2 * 2 1/2
D) 3 * 2 * 3 1/2
A) 3 * 2 * 2
B) 3 * 2 * 2 1/4
C) 3 * 2 * 2 1/2
D) 3 * 2 * 3 1/2
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
38
When computing box fill, a duplex receptacle is counted as ____________________ conductors of the size conductor attched to it.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
39
A ____________________ is a short length of wire used in electrical boxes to make connections to device terminals.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
40
The volume allowance for a 10 AWG conductor is ____________________ cubic inches.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
41
Explain the importance of the air barrier of a house, how air sealing contributes to air tightness of a house, and the proper role of electric boxes that interact with the air barrier.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck

