Deck 19: Service Panel Trim-Out

Full screen (f)
exit full mode
Question
The interrupting rating of fuses can be as high as __________ amperes.

A) 5,000
B) 10,000
C) 20,000
D) 300,000
Use Space or
up arrow
down arrow
to flip the card.
Question
The NEC permits overcurrent protection devices to be located in bathrooms.
Question
A(n) __________ fuse uses different fuse bases for each size fuse and an adapter that matches each fuse size is required.

A) cartridge
B) Edison base
C) Type S
D) stab
Question
Type S fuses are classified at __________ amperes.

A) 0 to 15
B) 16 to 20
C) 21 to 30
D) All of the above
Question
When installing an ungrounded conductor in a circuit breaker, approximately __________ of insulation is stripped from the end of the conductor.

A) 1/8"
B) 1/4"
C) 1/2"
D) 3/4"
Question
NEC Table __________ lists the ampacity of conductors used in residential wiring.

A) 240.6
B) 220.12
C) 250.66
D) 310.15(B)(16)
Question
All plug fuses are limited to circuits where the voltage between conductors does not exceed __________ volts. (General Rule)

A) 240
B) 125
C) 277
D) 208
Question
In residential wiring, a 12 AWG copper conductor is protected by a __________-ampere or lower OCPD.

A) 15
B) 20
C) 25
D) 30
Question
A circuit breaker used to switch fluorescent lighting must be listed and have __________ marked on it.

A) OK for fluorescent lighting
B) FL
C) SWD only
D) SWD or HID
Question
A 12 AWG branch circuit can be protected by a 15-ampere fuse or circuit breaker.
Question
On a 240-volt residential branch circuit or feeder circuit with 10 AWG conductors, a maximum of a __________-ampere overcurrent protection device must be used.

A) 20
B) 25
C) 30
D) Any of the above
Question
A device intended to provide protection from the effects of arc faults is called a(n) __________ circuit breaker.

A) ground fault circuit interrupter
B) arc fault circuit interrupter
C) special protection
D) fuse
Question
In residential wiring, all 120 volt, 15- and 20- amp branch circuits supplying outlets in family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, or similar rooms must be protected by a combination type AFCI.
Question
A two-pole circuit breaker is used to protect a 120-volt branch circuit.
Question
A(n) __________ fuse is enclosed in an insulating tube that confines the arc when the fuse blows and is available in either a ferrule or blade style.

A) cartridge
B) Edison base
C) type S
D) stab
Question
NEC Article __________ provides many installation requirements for overcurrent protection devices.

A) 210
B) 230
C) 250
D) None of the above
Question
A GFCI circuit breaker should be tested at least once a ___________.

A) day
B) week
C) month
D) year
Question
Which of the following will not cause an overcurrent condition?

A) Open circuit
B) Ground fault
C) Overload
D) Short circuit
Question
A single-pole circuit breaker has one stab contact and a two-pole circuit breaker has two stab contacts.
Question
A fuse type that uses the same standard screw base as an ordinary light bulb and where the different fuse sizes are interchangeable with each other is called a(n) __________ fuse.

A) cartridge
B) Edison base
C) Type S
D) stab
Question
For circuit breakers, if the interrupting rating is different than ____________________ amperes, it must be marked on the breaker.
Question
The color coding for a 15 amp Type S plug fuse adapter is __________.

A) blue
B) orange
C) green
D) any of the above
Question
Circuit breakers are always interchangeable with different manufacturer's panelboards.
Question
When working on an energized electrical panel, turning the main breaker 'OFF' disconnects power from the ____________________ side of the panel.
Question
Fuseholders for current-limiting fuses can not permit the insertion of fuses that are not ______________________________.
Question
Type S adapters are designed so that once inserted in a fuseholder, they cannot be ____________________.
Question
The color coding for a 30 amp Type S plug fuse is __________.

A) blue
B) orange
C) green
D) any of the above
Question
Cartridge fuses are available in both a __________ type and a __________ type.

A) long; short
B) round; oblong
C) ferrule; blade
D) open; closed
Question
Describe how you can tell the difference between a 'regular' circuit breaker and a GFCI or AFCI circuit breaker.
Question
Overcurrent protection devices must be readily accessible.
Question
If an electrician chooses to use plug fuses in a new electrical installation, they must be ____________________-plug fuses.
Question
Explain how a 240-volt circuit is wired differently than a 120/240-volt circuit.
Question
A 240 volt electric water heater branch circuit or feeder circuit will require a __________ circuit breaker.

A) single-pole
B) double-pole
C) HACR
D) three-pole
Question
Explain what a hexagonal configuration on a plug fuse indicates.
Question
The circuit breakers are attached to the bus bar by contacts in the breakers commonly called ____________________.
Question
Because electric motors draw more current to get started than they do when running, ____________________ fuses are used to protect motor circuits.
Question
Because all of the ampacities listed in Table 310.15(B)(16) do not correspond with a standard fuse or circuit breaker size, the NEC allows the next __________ standard overcurrent device to be used up to 800 amps.
Question
A 120 volt branch circuit or feeder circuit supplying a dishwasher will require a __________ circuit breaker.

A) single-pole
B) double-pole
C) HACR
D) three-pole
Question
The highest current at rated voltage that a device is intended to interrupt under standard test conditions is called the ____________________ rating.
Question
All circuit breakers must be designed so that any fault must be cleared before the circuit breaker can be ____________________.
Question
Name an advantage to installing a multiwire circuit in residential wiring.
Question
When installing a two-pole circuit breaker to protect a two-wire Type NM cable feeding a 240 volt electric water heater, describe what needs to be done with the white conductor in the cable that will be terminated at the breaker.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/42
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 19: Service Panel Trim-Out
1
The interrupting rating of fuses can be as high as __________ amperes.

A) 5,000
B) 10,000
C) 20,000
D) 300,000
D
2
The NEC permits overcurrent protection devices to be located in bathrooms.
False
3
A(n) __________ fuse uses different fuse bases for each size fuse and an adapter that matches each fuse size is required.

A) cartridge
B) Edison base
C) Type S
D) stab
C
4
Type S fuses are classified at __________ amperes.

A) 0 to 15
B) 16 to 20
C) 21 to 30
D) All of the above
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
5
When installing an ungrounded conductor in a circuit breaker, approximately __________ of insulation is stripped from the end of the conductor.

A) 1/8"
B) 1/4"
C) 1/2"
D) 3/4"
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
6
NEC Table __________ lists the ampacity of conductors used in residential wiring.

A) 240.6
B) 220.12
C) 250.66
D) 310.15(B)(16)
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
7
All plug fuses are limited to circuits where the voltage between conductors does not exceed __________ volts. (General Rule)

A) 240
B) 125
C) 277
D) 208
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
8
In residential wiring, a 12 AWG copper conductor is protected by a __________-ampere or lower OCPD.

A) 15
B) 20
C) 25
D) 30
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
9
A circuit breaker used to switch fluorescent lighting must be listed and have __________ marked on it.

A) OK for fluorescent lighting
B) FL
C) SWD only
D) SWD or HID
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
10
A 12 AWG branch circuit can be protected by a 15-ampere fuse or circuit breaker.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
11
On a 240-volt residential branch circuit or feeder circuit with 10 AWG conductors, a maximum of a __________-ampere overcurrent protection device must be used.

A) 20
B) 25
C) 30
D) Any of the above
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
12
A device intended to provide protection from the effects of arc faults is called a(n) __________ circuit breaker.

A) ground fault circuit interrupter
B) arc fault circuit interrupter
C) special protection
D) fuse
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
13
In residential wiring, all 120 volt, 15- and 20- amp branch circuits supplying outlets in family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, or similar rooms must be protected by a combination type AFCI.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
14
A two-pole circuit breaker is used to protect a 120-volt branch circuit.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
15
A(n) __________ fuse is enclosed in an insulating tube that confines the arc when the fuse blows and is available in either a ferrule or blade style.

A) cartridge
B) Edison base
C) type S
D) stab
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
16
NEC Article __________ provides many installation requirements for overcurrent protection devices.

A) 210
B) 230
C) 250
D) None of the above
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
17
A GFCI circuit breaker should be tested at least once a ___________.

A) day
B) week
C) month
D) year
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
18
Which of the following will not cause an overcurrent condition?

A) Open circuit
B) Ground fault
C) Overload
D) Short circuit
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
19
A single-pole circuit breaker has one stab contact and a two-pole circuit breaker has two stab contacts.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
20
A fuse type that uses the same standard screw base as an ordinary light bulb and where the different fuse sizes are interchangeable with each other is called a(n) __________ fuse.

A) cartridge
B) Edison base
C) Type S
D) stab
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
21
For circuit breakers, if the interrupting rating is different than ____________________ amperes, it must be marked on the breaker.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
22
The color coding for a 15 amp Type S plug fuse adapter is __________.

A) blue
B) orange
C) green
D) any of the above
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
23
Circuit breakers are always interchangeable with different manufacturer's panelboards.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
24
When working on an energized electrical panel, turning the main breaker 'OFF' disconnects power from the ____________________ side of the panel.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
25
Fuseholders for current-limiting fuses can not permit the insertion of fuses that are not ______________________________.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
26
Type S adapters are designed so that once inserted in a fuseholder, they cannot be ____________________.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
27
The color coding for a 30 amp Type S plug fuse is __________.

A) blue
B) orange
C) green
D) any of the above
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
28
Cartridge fuses are available in both a __________ type and a __________ type.

A) long; short
B) round; oblong
C) ferrule; blade
D) open; closed
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
29
Describe how you can tell the difference between a 'regular' circuit breaker and a GFCI or AFCI circuit breaker.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
30
Overcurrent protection devices must be readily accessible.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
31
If an electrician chooses to use plug fuses in a new electrical installation, they must be ____________________-plug fuses.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
32
Explain how a 240-volt circuit is wired differently than a 120/240-volt circuit.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
33
A 240 volt electric water heater branch circuit or feeder circuit will require a __________ circuit breaker.

A) single-pole
B) double-pole
C) HACR
D) three-pole
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
34
Explain what a hexagonal configuration on a plug fuse indicates.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
35
The circuit breakers are attached to the bus bar by contacts in the breakers commonly called ____________________.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
36
Because electric motors draw more current to get started than they do when running, ____________________ fuses are used to protect motor circuits.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
37
Because all of the ampacities listed in Table 310.15(B)(16) do not correspond with a standard fuse or circuit breaker size, the NEC allows the next __________ standard overcurrent device to be used up to 800 amps.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
38
A 120 volt branch circuit or feeder circuit supplying a dishwasher will require a __________ circuit breaker.

A) single-pole
B) double-pole
C) HACR
D) three-pole
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
39
The highest current at rated voltage that a device is intended to interrupt under standard test conditions is called the ____________________ rating.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
40
All circuit breakers must be designed so that any fault must be cleared before the circuit breaker can be ____________________.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
41
Name an advantage to installing a multiwire circuit in residential wiring.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
42
When installing a two-pole circuit breaker to protect a two-wire Type NM cable feeding a 240 volt electric water heater, describe what needs to be done with the white conductor in the cable that will be terminated at the breaker.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 42 flashcards in this deck.