Deck 11: Cable Installation

Full screen (f)
exit full mode
Question
Service entrance cable with an uninsulated conductor (Type SEU) is permitted to be used as the branch circuit wiring method for an electric range.
Use Space or
up arrow
down arrow
to flip the card.
Question
The NEC requires insulated staples to be used when securing and supporting Type NM cable.
Question
Type AC cable installed in thermal insulation must have conductors rated at 900C (1940F).
Question
Which of the following is not a type of nonmetallic sheathed cable?

A) Type NM
B) Type NM-B
C) Type NMC
D) Type NM-U
Question
If a hole is bored into a stud and there is less than 1 1/4" between the edge of the hole and the edge of the stud, a steel plate at least 1/16" thick or a listed and marked steel plate that is less than 1/16" if it still provides equal or greater protection against nail or screw penetration, must be used.
Question
Romex must be secured at no more than __________ inches from all electrical boxes except a nonmetallic single-gang box.

A) 6"
B) 8"
C) 10"
D) 12"
Question
Even though the NEC permits Type NM cable to be used in one- and two-family homes, it may not be approved for use in your area by the AHJ.
Question
Suspended ceiling grids are permitted by the NEC to support nonmetallic sheathed cables.
Question
Romex installed in either a metal or plastic two-gang device box with interior cable clamps, must be secured no more than __________ from the device box.

A) 6"
B) 8"
C) 10"
D) 12"
Question
Most engineered I-beams come from the manufacturer with perforated knockouts that allow an electrician to remove the knockout and install cables through the holes.
Question
The electrician can incorporate waste from rough and finish wiring phases into the jobsite-recycling system.
Question
An insulated anti-short fitting required to be installed in the ends of Type AC cable to protect the wires from abrasion is typically called a(n) __________.

A) orange head
B) red head
C) blue devil
D) blue head
Question
Cables run along the sides of framing members must be installed at least __________ from the nearest edge of studs, joists, or rafters.

A) 3"
B) 6"
C) 1-1/4"
D) None of the above
Question
Type NM and Type UF cables must have their cable sheath extend into nonmetallic boxes and beyond any cable clamp at least 1/2 inch (6 mm).
Question
During the rough-in wiring phase, an electrician always routes cable through floors or ceilings, which provides shorter routes than do perimeter walls.
Question
When service entrance cable is used for branch circuits, the only conductor permitted to be bare is the equipment grounding conductor.
Question
The inner edge of any bend in nonmetallic sheathed cable cannot be less than __________ times the cable diameter.

A) 6
B) 5
C) 4
D) 3
Question
Romex is considered to be supported when it passes through bored or punched holes in framing members that are no more than 4 1/2 feet apart.
Question
A 'homerun' may enter a loadcenter through knockouts in the back, sides, top, or bottom of the loadcenter.
Question
In attics not accessible by permanent stairs or ladders, Romex run across the top of floor joists within __________ of the scuttle hole must be protected by means such as guard strips.

A) 3'
B) 5'
C) 6'
D) 7'
Question
When unrolling cable from a coil, the best way is to pull the cable out of the coil from the __________.

A) outside of the coil
B) inside of the coil
C) underside of the coil
D) None of the above
Question
Manufacturers of Type NM cable are now color coding their cables. The color typically used for 12 AWG Romex cable is __________.

A) red
B) blue
C) yellow
D) orange
Question
The maximum distance between supports for a Type NM cable is __________.

A) 3 feet
B) 4 1/2 feet
C) 6 feet
D) 10 feet
Question
If Type AC is run through a hole in a framing member that has an edge closer than ____________________ inch(es) to the edge of the framing member, it must be protected by a metal plate at least 1/16" thick.
Question
Type MC cable of sizes 14, 12, and 10 AWG must be secured within 12" from every box and then must be supported at intervals not exceeding __________.

A) 4.5'
B) 5'
C) 6'
D) 7'
Question
In single-gang nonmetallic electrical device boxes, at least __________ of the cable sheathing must extend into the box.

A) 1/8"
B) 1/4"
C) 1/2"
D) 3/4"
Question
The part of a branch circuit that originates in the loadcenter and provides electrical power to the first electrical box in a circuit is called a __________.

A) ground out
B) home run
C) fly ball
D) strike out
Question
Unrolling cable from a coil is very easily done with a device commonly called a __________.

A) spinner
B) roller
C) reel jack
D) fish tape
Question
The NEC requires at least __________ of free conductor in electrical device boxes for connection to switches and receptacles.

A) 6"
B) 8"
C) 10"
D) 12"
Question
All of the following cable types are typically used in residential wiring except __________.

A) Type NM
B) Type AC
C) Type MI
D) Type MC
Question
Type MC cable with an interlocked armor or corrugated sheath cannot be bent to a radius of less than __________ times the external diameter of the metallic sheath.

A) 3
B) 5
C) 7
D) 9
Question
When installing Type MC cable in a house, an anti-short bushing (red head) is required at each end to provide protection for the conductors from the sharp edges of the cable armor.

A) True
B) False
Question
Where passing through a floor and located on the outside of a wall, nonmetallic sheathed cable must be enclosed in rigid metal conduit, intermediate metal conduit, electrical metallic tubing, or Schedule 80 rigid PVC conduit extending at least ____________________ inches above the floor.
Question
When installing Romex into a single-gang nonmetallic device box, the cable must be secured no more than __________ from the box.

A) 8"
B) 10"
C) 12"
D) None of the above
Question
Electricians commonly refer to Armored Clad Cable as ____________________ cable.
Question
Type NM cable is often purchased in __________ foot rolls that are packaged in plastic wrapping or in cardboard boxes.

A) 100
B) 150
C) 250
D) 1000
Question
Type AC cable must be supported at intervals not exceeding ____________________ feet along the run.
Question
The radius of the curve of the inner bend in Armored Cable must not be less than __________ times the diameter of the cable.

A) 3
B) 4
C) 5
D) 6
Question
Which of the following cables are not permitted to be secured directly to the bottom edge of joists in an unfinished basement?

A) 6/2 NM cable
B) 6/3 NM cable
C) 8/2 NM cable
D) 8/3 NM cable
Question
If a cable is placed in a notch in wood studs or other wood framing members, a steel plate at least ____________________ inch thick must be used to protect the cable.
Question
Explain why two-wire Romex cable cannot be stapled on edge.
Question
Explain why you do not overtighten the clamp of a metal cable connector when securing a cable to an electrical enclosure.
Question
Explain the use of running boards in unfinished basements.
Question
Section 334.80 covers the ampacity of Type NM cable. It states that even though the cable's insulation is rated at 900 C (1940 F) the allowable ampacity of the cable is taken from the _____ degree C column in Table 310.15(B)(16).
Question
Where three or more Type NM cables containing two or more current carrying conductors are installed in contact with thermal insulation without maintaining spacing between the cables, the allowable ampacity must be adjusted for more than three current carrying conductors using Table __________.
Question
Explain why the sheathing of nonmetallic sheathed cable should extend into the device box or beyond the cable clamp approximately 1/4".
Question
Explain what a 'jug handle' is.
Question
Explain what type of protection must be used when running Romex through bored or punched holes in metal studs.
Question
Where three or more Type NM cables containing two or more current carrying conductors are installed without maintaining spacing between the cables, through the same hole in wood framing members that is to be sealed with thermal insulation, caulk, or sealing foam, the allowable ampacity must be adjusted for more than three current carrying conductors using Table __________.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/49
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 11: Cable Installation
1
Service entrance cable with an uninsulated conductor (Type SEU) is permitted to be used as the branch circuit wiring method for an electric range.
False
2
The NEC requires insulated staples to be used when securing and supporting Type NM cable.
False
3
Type AC cable installed in thermal insulation must have conductors rated at 900C (1940F).
True
4
Which of the following is not a type of nonmetallic sheathed cable?

A) Type NM
B) Type NM-B
C) Type NMC
D) Type NM-U
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
5
If a hole is bored into a stud and there is less than 1 1/4" between the edge of the hole and the edge of the stud, a steel plate at least 1/16" thick or a listed and marked steel plate that is less than 1/16" if it still provides equal or greater protection against nail or screw penetration, must be used.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
6
Romex must be secured at no more than __________ inches from all electrical boxes except a nonmetallic single-gang box.

A) 6"
B) 8"
C) 10"
D) 12"
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
7
Even though the NEC permits Type NM cable to be used in one- and two-family homes, it may not be approved for use in your area by the AHJ.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
8
Suspended ceiling grids are permitted by the NEC to support nonmetallic sheathed cables.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
9
Romex installed in either a metal or plastic two-gang device box with interior cable clamps, must be secured no more than __________ from the device box.

A) 6"
B) 8"
C) 10"
D) 12"
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
10
Most engineered I-beams come from the manufacturer with perforated knockouts that allow an electrician to remove the knockout and install cables through the holes.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
11
The electrician can incorporate waste from rough and finish wiring phases into the jobsite-recycling system.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
12
An insulated anti-short fitting required to be installed in the ends of Type AC cable to protect the wires from abrasion is typically called a(n) __________.

A) orange head
B) red head
C) blue devil
D) blue head
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
13
Cables run along the sides of framing members must be installed at least __________ from the nearest edge of studs, joists, or rafters.

A) 3"
B) 6"
C) 1-1/4"
D) None of the above
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
14
Type NM and Type UF cables must have their cable sheath extend into nonmetallic boxes and beyond any cable clamp at least 1/2 inch (6 mm).
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
15
During the rough-in wiring phase, an electrician always routes cable through floors or ceilings, which provides shorter routes than do perimeter walls.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
16
When service entrance cable is used for branch circuits, the only conductor permitted to be bare is the equipment grounding conductor.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
17
The inner edge of any bend in nonmetallic sheathed cable cannot be less than __________ times the cable diameter.

A) 6
B) 5
C) 4
D) 3
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
18
Romex is considered to be supported when it passes through bored or punched holes in framing members that are no more than 4 1/2 feet apart.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
19
A 'homerun' may enter a loadcenter through knockouts in the back, sides, top, or bottom of the loadcenter.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
20
In attics not accessible by permanent stairs or ladders, Romex run across the top of floor joists within __________ of the scuttle hole must be protected by means such as guard strips.

A) 3'
B) 5'
C) 6'
D) 7'
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
21
When unrolling cable from a coil, the best way is to pull the cable out of the coil from the __________.

A) outside of the coil
B) inside of the coil
C) underside of the coil
D) None of the above
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
22
Manufacturers of Type NM cable are now color coding their cables. The color typically used for 12 AWG Romex cable is __________.

A) red
B) blue
C) yellow
D) orange
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
23
The maximum distance between supports for a Type NM cable is __________.

A) 3 feet
B) 4 1/2 feet
C) 6 feet
D) 10 feet
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
24
If Type AC is run through a hole in a framing member that has an edge closer than ____________________ inch(es) to the edge of the framing member, it must be protected by a metal plate at least 1/16" thick.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
25
Type MC cable of sizes 14, 12, and 10 AWG must be secured within 12" from every box and then must be supported at intervals not exceeding __________.

A) 4.5'
B) 5'
C) 6'
D) 7'
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
26
In single-gang nonmetallic electrical device boxes, at least __________ of the cable sheathing must extend into the box.

A) 1/8"
B) 1/4"
C) 1/2"
D) 3/4"
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
27
The part of a branch circuit that originates in the loadcenter and provides electrical power to the first electrical box in a circuit is called a __________.

A) ground out
B) home run
C) fly ball
D) strike out
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
28
Unrolling cable from a coil is very easily done with a device commonly called a __________.

A) spinner
B) roller
C) reel jack
D) fish tape
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
29
The NEC requires at least __________ of free conductor in electrical device boxes for connection to switches and receptacles.

A) 6"
B) 8"
C) 10"
D) 12"
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
30
All of the following cable types are typically used in residential wiring except __________.

A) Type NM
B) Type AC
C) Type MI
D) Type MC
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
31
Type MC cable with an interlocked armor or corrugated sheath cannot be bent to a radius of less than __________ times the external diameter of the metallic sheath.

A) 3
B) 5
C) 7
D) 9
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
32
When installing Type MC cable in a house, an anti-short bushing (red head) is required at each end to provide protection for the conductors from the sharp edges of the cable armor.

A) True
B) False
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
33
Where passing through a floor and located on the outside of a wall, nonmetallic sheathed cable must be enclosed in rigid metal conduit, intermediate metal conduit, electrical metallic tubing, or Schedule 80 rigid PVC conduit extending at least ____________________ inches above the floor.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
34
When installing Romex into a single-gang nonmetallic device box, the cable must be secured no more than __________ from the box.

A) 8"
B) 10"
C) 12"
D) None of the above
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
35
Electricians commonly refer to Armored Clad Cable as ____________________ cable.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
36
Type NM cable is often purchased in __________ foot rolls that are packaged in plastic wrapping or in cardboard boxes.

A) 100
B) 150
C) 250
D) 1000
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
37
Type AC cable must be supported at intervals not exceeding ____________________ feet along the run.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
38
The radius of the curve of the inner bend in Armored Cable must not be less than __________ times the diameter of the cable.

A) 3
B) 4
C) 5
D) 6
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
39
Which of the following cables are not permitted to be secured directly to the bottom edge of joists in an unfinished basement?

A) 6/2 NM cable
B) 6/3 NM cable
C) 8/2 NM cable
D) 8/3 NM cable
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
40
If a cable is placed in a notch in wood studs or other wood framing members, a steel plate at least ____________________ inch thick must be used to protect the cable.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
41
Explain why two-wire Romex cable cannot be stapled on edge.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
42
Explain why you do not overtighten the clamp of a metal cable connector when securing a cable to an electrical enclosure.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
43
Explain the use of running boards in unfinished basements.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
44
Section 334.80 covers the ampacity of Type NM cable. It states that even though the cable's insulation is rated at 900 C (1940 F) the allowable ampacity of the cable is taken from the _____ degree C column in Table 310.15(B)(16).
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
45
Where three or more Type NM cables containing two or more current carrying conductors are installed in contact with thermal insulation without maintaining spacing between the cables, the allowable ampacity must be adjusted for more than three current carrying conductors using Table __________.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
46
Explain why the sheathing of nonmetallic sheathed cable should extend into the device box or beyond the cable clamp approximately 1/4".
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
47
Explain what a 'jug handle' is.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
48
Explain what type of protection must be used when running Romex through bored or punched holes in metal studs.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
49
Where three or more Type NM cables containing two or more current carrying conductors are installed without maintaining spacing between the cables, through the same hole in wood framing members that is to be sealed with thermal insulation, caulk, or sealing foam, the allowable ampacity must be adjusted for more than three current carrying conductors using Table __________.
Unlock Deck
Unlock for access to all 49 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 49 flashcards in this deck.