The NEC permits overcurrent protection devices to be located in bathrooms.
False
2
Which of the following will not cause an overcurrent condition?
A) Open circuit
B) Ground fault
C) Overload
D) Short circuit
A) Open circuit
B) Ground fault
C) Overload
D) Short circuit
A
3
A 12 AWG branch circuit can be protected by a 15-ampere fuse or circuit breaker.
True
4
When installing an ungrounded conductor in a circuit breaker, approximately __________ of insulation is stripped from the end of the conductor.
A) 1/8"
B) 1/4"
C) 1/2"
D) 3/4"
A) 1/8"
B) 1/4"
C) 1/2"
D) 3/4"
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
5
NEC Article __________ provides many installation requirements for overcurrent protection devices.
A) 210
B) 230
C) 250
D) None of the above
A) 210
B) 230
C) 250
D) None of the above
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
6
A two-pole circuit breaker is used to protect a 120-volt branch circuit.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
7
A(n) __________ fuse uses different fuse bases for each size fuse and an adapter that matches each fuse size is required.
A) cartridge
B) Edison base
C) Type S
D) stab
A) cartridge
B) Edison base
C) Type S
D) stab
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
8
A device intended to provide protection from the effects of arc faults is called a(n) __________ circuit breaker.
A) ground fault circuit interrupter
B) arc fault circuit interrupter
C) special protection
D) fuse
A) ground fault circuit interrupter
B) arc fault circuit interrupter
C) special protection
D) fuse
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
9
On a 240-volt residential branch circuit or feeder circuit with 10 AWG conductors, a maximum of a __________-ampere overcurrent protection device must be used.
A) 20
B) 25
C) 30
D) Any of the above
A) 20
B) 25
C) 30
D) Any of the above
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
10
A(n) __________ fuse is enclosed in an insulating tube that confines the arc when the fuse blows and is available in either a ferrule or blade style.
A) cartridge
B) Edison base
C) type S
D) stab
A) cartridge
B) Edison base
C) type S
D) stab
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
11
In residential wiring, all 120 volt, 15- and 20- amp branch circuits supplying outlets or devices in kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, laundry areas, or similar rooms must be AFCI protected.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
12
A circuit breaker used to switch fluorescent lighting must be listed and have __________ marked on it.
A) OK for fluorescent lighting
B) FL
C) SWD only
D) SWD or HID
A) OK for fluorescent lighting
B) FL
C) SWD only
D) SWD or HID
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
13
All plug fuses are limited to circuits where the voltage between conductors does not exceed __________ volts. (General Rule)
A) 240
B) 125
C) 277
D) 208
A) 240
B) 125
C) 277
D) 208
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
14
A fuse type that uses the same standard screw base as an ordinary light bulb and where the different fuse sizes are interchangeable with each other is called a(n) __________ fuse.
A) cartridge
B) Edison base
C) Type S
D) stab
A) cartridge
B) Edison base
C) Type S
D) stab
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
15
Type S fuses are classified at __________ amperes.
A) 0 to 15
B) 16 to 20
C) 21 to 30
D) All of the above
A) 0 to 15
B) 16 to 20
C) 21 to 30
D) All of the above
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
16
A GFCI or AFCI circuit breaker should be tested at least once a ___________.
A) day
B) week
C) month
D) year
A) day
B) week
C) month
D) year
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
17
A single-pole circuit breaker has one stab contact and a two-pole circuit breaker has two stab contacts.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
18
NEC Table __________ lists the ampacity of conductors used in residential wiring.
A) 240.6
B) 220.12
C) 250.66
D) 310.15(B)(16)
A) 240.6
B) 220.12
C) 250.66
D) 310.15(B)(16)
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
19
In residential wiring, a 12 AWG copper conductor is protected by a __________-ampere or lower OCPD.
A) 15
B) 20
C) 25
D) 30
A) 15
B) 20
C) 25
D) 30
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
20
The interrupting rating of fuses can be as high as __________ amperes.
A) 5,000
B) 10,000
C) 20,000
D) 300,000
A) 5,000
B) 10,000
C) 20,000
D) 300,000
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
21
The circuit breakers are attached to the bus bar by contacts in the breakers commonly called ____________________.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
22
A 120 volt branch circuit or feeder circuit supplying a dishwasher will require a __________ circuit breaker.
A) single-pole
B) double-pole
C) HACR
D) three-pole
A) single-pole
B) double-pole
C) HACR
D) three-pole
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
23
The highest current at rated voltage that a device is intended to interrupt under standard test conditions is called the ____________________ rating.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
24
When working on an energized main breaker electrical panel, turning the main breaker 'OFF' disconnects power from the ____________________ side of the panel.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
25
Type S adapters are designed so that once inserted in a fuseholder, they cannot be ____________________.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
26
Cartridge fuses are available in both a __________ type and a __________ type.
A) long; short
B) round; oblong
C) ferrule; blade
D) open; closed
A) long; short
B) round; oblong
C) ferrule; blade
D) open; closed
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
27
Fuseholders for current-limiting fuses can not permit the insertion of fuses that are not ______________________________.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
28
Circuit breakers are always interchangeable with different manufacturer's panelboards.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
29
For circuit breakers, if the interrupting rating is different than ____________________ amperes, it must be marked on the breaker.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
30
Explain how a 240-volt circuit is wired differently than a 120/240-volt circuit.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
31
Explain what a hexagonal configuration on a plug fuse indicates.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
32
The color coding for a 30 amp Type S plug fuse is __________.
A) blue
B) orange
C) green
D) any of the above
A) blue
B) orange
C) green
D) any of the above
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
33
Because all of the ampacities listed in Table 310.15(B)(16) do not correspond with a standard fuse or circuit breaker size, the NEC allows the next __________ standard overcurrent device to be used up to 800 amps.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
34
All circuit breakers must be designed so that any fault must be cleared before the circuit breaker can be ____________________.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
35
The color coding for a 15 amp Type S plug fuse adapter is __________.
A) blue
B) orange
C) green
D) any of the above
A) blue
B) orange
C) green
D) any of the above
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
36
Because electric motors draw more current to get started than they do when running, ____________________ fuses are used to protect motor circuits.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
37
Describe how you can tell the difference between a 'regular' circuit breaker and a GFCI or AFCI circuit breaker.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
38
If an electrician chooses to use plug fuses in a new electrical installation, they must be ____________________-plug fuses.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
39
A 240 volt electric water heater branch circuit or feeder circuit will require a __________ circuit breaker.
A) single-pole
B) double-pole
C) HACR
D) three-pole
A) single-pole
B) double-pole
C) HACR
D) three-pole
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
40
Overcurrent protection devices must be readily accessible.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
41
Name an advantage to installing a multiwire circuit in residential wiring.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck
42
When installing a two-pole circuit breaker to protect a two-wire Type NM cable feeding a 240 volt electric water heater, describe what needs to be done with the white conductor in the cable that will be terminated at the breaker.
Unlock Deck
Unlock for access to all 42 flashcards in this deck.
Unlock Deck
k this deck