Deck 2: Hardware and Materials Used in Residential Wiring

Full screen (f)
exit full mode
Question
AHJs usually base their approval of electrical equipment on whether it is listed and labeled by a nationally recognized testing laboratory (NRTL).
Use Space or
up arrow
down arrow
to flip the card.
Question
On a GFCI receptacle, the incoming power is connected to the line terminals.
Question
The __________ is a scale of specified diameters and cross sections for wire sizing and is the standard wire sizing scale for the United States.

A) American Wire Gauge
B) Metric System
C) United States Measuring System
D) None of the above
Question
A low resistance path, which results in a high value of current that flows around, rather than through, a circuit is called a(n) __________ circuit.

A) open
B) short
C) grounded
D) grounding
Question
The National Electrical Code requires Type NM cable to be secured no more than __________ inches from single-gang nonmetallic device boxes.

A) 6
B) 8
C) 10
D) 12
Question
Which of the following conductors is the largest?

A) 8 AWG
B) 10 AWG
C) 12 AWG
D) 14 AWG
Question
An accidental connection of a "hot" conductor and a grounded piece of equipment or the grounded conductor is called a(n) __________.

A) open circuit
B) grounding conductor
C) ground fault
D) complete circuit
Question
It is the __________ who has the job of approving the electrical materials used for a residential electrical installation.

A) electrician
B) foreman
C) architect
D) authority having jurisdiction
Question
On a duplex receptacle, the silver screw is used to terminate the white grounded conductor.
Question
When nonmetallic device boxes that are 2-gang or more are used, the installed Type NM cable must be secured no more than __________ inches from the box.

A) 8
B) 10
C) 12
D) 18
Question
The __________ circuit conductor is used as the grounded conductor and returns current from the load back to the source.

A) black
B) white
C) red
D) green
Question
Staples are the most common item used to secure and support cables in residential wiring.
Question
Boxes with mounting ears are typically called new work boxes; boxes without mounting ears are referred to as old work boxes.
Question
In the AWG system: the smaller the number, the smaller the conductor; and the larger the number, the larger the conductor.
Question
A wirenut is the most common wire connector used by electricians to splice together two or more conductors.
Question
When using aluminum conductors, __________ size conductor must be used to carry the same amount of current as a copper conductor.

A) a smaller
B) the same
C) a larger
D) the same or larger
Question
The __________ is an organization that develops electrical equipment standards that all member groups follow when designing and producing electrical equipment.

A) Underwriters Laboratories
B) Canadian Standards Association
C) National Electrical Manufacturers Association
D) National Electrical Code
Question
Schedule 40 rigid polyvinyl chloride conduit (Type PVC) conduit has a smaller inside diameter than Schedule 80 rigid nonmetallic PVC conduit.
Question
Type __________ cable is used for underground installations of branch and feeder circuits.

A) NM
B) NM-B
C) SE
D) None of the above
Question
Manufacturers of nonmetallic sheathed cable color code a 12/2 Type NM cable with the color orange.
Question
All ____________________ boxes must be accessible after they are installed.
Question
A GFCI circuit breaker is easily recognizable by the 'push-to-test' button and the __________.

A) yellow body
B) length of white wire attached to it
C) larger operating handle
D) smaller body size
Question
A switch that is used on 240-volt circuits to control a load from one location is called a __________ switch.

A) single-pole
B) double-pole
C) occupancy
D) combination
Question
__________ are the most often used type of overcurrent protection device used in residential wiring.

A) Circuit breakers
B) Edison base fuses
C) Plug fuses
D) Cartridge fuses
Question
__________ plug fuses are considered non-tamperable and are used in new installations requiring plug fuses.

A) Edison base
B) Type S
C) Cartridge
D) Plug
Question
Almost all 15- or 20-amp, 125-volt receptacles in a house must be __________.

A) tamper-resistant
B) terminated
C) color-coded
D) self-grounding
Question
Type __________ cable is used for underground service entrance installations.

A) SE
B) UF
C) USE
D) NM-B
Question
Which of the following switches has ON/OFF marked on the switch handle?

A) Three-way
B) Double-pole
C) Four-way
D) None of the above
Question
CO/ALR marked on a receptacle indicates that __________ conductors may be terminated to it.

A) copper
B) copper-clad aluminum
C) aluminum
D) All of the above
E) A and B only
Question
The NEC requires rigid metal conduit to be supported within __________ feet of each box and then no more than every __________ feet thereafter. (general rule)

A) 3, 8
B) 5, 10
C) 2, 10
D) 3, 10
Question
The ______ is the device that is inserted into a receptacle to establish a connection between the conductors of the attached flexible cord and the conductors connected to the receptacle.

A) outlet
B) fuse
C) connector
D) attachment plug
Question
Romex is a trade name used by electricians to refer to __________.

A) armored cable
B) metal clad cable
C) underground feeder cable
D) nonmetallic sheathed cable
Question
A _____ is described as a factory assembly of two or more conductors that has an overall outer sheathing that can be nonmetallic or metallic.

A) wire
B) conductor
C) cable
D) None of the above
Question
If a switching device has the marking CU ONLY on it, an electrician can use only __________ wire with the device.

A) copper
B) copper clad aluminum
C) aluminum
D) any of the above
Question
When two or more electrical device boxes are joined together for the purpose of holding more than one device it is called __________.

A) fitting
B) ganging
C) sticking
D) boxing
Question
A weatherproof enclosure designed to give protection from falling dirt, rain, snow, sleet, and windblown dust is classified as a _____ enclosure and will need to be installed for outside appliciations.

A) NEMA 1
B) NEMA 2
C) NEMA 3R
D) NEMA 12
Question
The ____________________ of a conductor refers to its ability to carry current.
Question
The ungrounded 'hot' conductor is terminated to the __________ terminal on a duplex receptacle.

A) brass
B) silver
C) green
D) black
Question
A part of an electrical box that is designed to be removed so that a cable or raceway can be connected to the box is called a __________.

A) knockout
B) mounting bracket
C) cable clamp
D) plaster ear
Question
A _____ is a type of electrical panel that contains the main disconnecting means for the residential service entrance as well as the fuses or circuit breakers used to protect circuits and equipment like electric water heaters, ranges, dryers, and lighting.

A) safety switch
B) loadcenter
C) sub-panel
D) meter socket
Question
In residential wiring, the NEC requires a ____________________-amp circuit breaker or fuse to be used with 12 AWG copper conductors.
Question
A single-pole breaker is used on a circuit voltage of ____________________ volts and a two-pole breaker is used on a circuit voltage of ____________________ volts in residential wiring.
Question
Electricians often refer to Type AC cable as ____________________ cable.
Question
In certain locations in the United States, the AHJ may not allow nonmetallic sheathed cable in residential construction. The alternative wiring method most often used is _____________.
Question
A(n) ____________________ is a point on the wiring system at which current is taken to supply equipment.
Question
Explain the purpose of an antioxidant in electrical wiring.
Question
_________________________ plug fuses cannot be used in new installations.
Question
Explain when three-way switches are used in a residential lighting circuit.
Question
____________________ is a measure of how much a fastener is being tightened and is measured in foot-pounds or inch-pounds.
Question
A ____________________ is an overcurrent device that opens a circuit when a fusible link is melted away by the extreme heat caused by an overcurrent.
Question
____________________ devices are used when more than one device is needed at one location.
Question
Explain how a product gets listed.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/52
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 2: Hardware and Materials Used in Residential Wiring
1
AHJs usually base their approval of electrical equipment on whether it is listed and labeled by a nationally recognized testing laboratory (NRTL).
True
2
On a GFCI receptacle, the incoming power is connected to the line terminals.
True
3
The __________ is a scale of specified diameters and cross sections for wire sizing and is the standard wire sizing scale for the United States.

A) American Wire Gauge
B) Metric System
C) United States Measuring System
D) None of the above
A
4
A low resistance path, which results in a high value of current that flows around, rather than through, a circuit is called a(n) __________ circuit.

A) open
B) short
C) grounded
D) grounding
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
5
The National Electrical Code requires Type NM cable to be secured no more than __________ inches from single-gang nonmetallic device boxes.

A) 6
B) 8
C) 10
D) 12
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
6
Which of the following conductors is the largest?

A) 8 AWG
B) 10 AWG
C) 12 AWG
D) 14 AWG
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
7
An accidental connection of a "hot" conductor and a grounded piece of equipment or the grounded conductor is called a(n) __________.

A) open circuit
B) grounding conductor
C) ground fault
D) complete circuit
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
8
It is the __________ who has the job of approving the electrical materials used for a residential electrical installation.

A) electrician
B) foreman
C) architect
D) authority having jurisdiction
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
9
On a duplex receptacle, the silver screw is used to terminate the white grounded conductor.
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
10
When nonmetallic device boxes that are 2-gang or more are used, the installed Type NM cable must be secured no more than __________ inches from the box.

A) 8
B) 10
C) 12
D) 18
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
11
The __________ circuit conductor is used as the grounded conductor and returns current from the load back to the source.

A) black
B) white
C) red
D) green
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
12
Staples are the most common item used to secure and support cables in residential wiring.
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
13
Boxes with mounting ears are typically called new work boxes; boxes without mounting ears are referred to as old work boxes.
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
14
In the AWG system: the smaller the number, the smaller the conductor; and the larger the number, the larger the conductor.
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
15
A wirenut is the most common wire connector used by electricians to splice together two or more conductors.
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
16
When using aluminum conductors, __________ size conductor must be used to carry the same amount of current as a copper conductor.

A) a smaller
B) the same
C) a larger
D) the same or larger
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
17
The __________ is an organization that develops electrical equipment standards that all member groups follow when designing and producing electrical equipment.

A) Underwriters Laboratories
B) Canadian Standards Association
C) National Electrical Manufacturers Association
D) National Electrical Code
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
18
Schedule 40 rigid polyvinyl chloride conduit (Type PVC) conduit has a smaller inside diameter than Schedule 80 rigid nonmetallic PVC conduit.
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
19
Type __________ cable is used for underground installations of branch and feeder circuits.

A) NM
B) NM-B
C) SE
D) None of the above
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
20
Manufacturers of nonmetallic sheathed cable color code a 12/2 Type NM cable with the color orange.
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
21
All ____________________ boxes must be accessible after they are installed.
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
22
A GFCI circuit breaker is easily recognizable by the 'push-to-test' button and the __________.

A) yellow body
B) length of white wire attached to it
C) larger operating handle
D) smaller body size
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
23
A switch that is used on 240-volt circuits to control a load from one location is called a __________ switch.

A) single-pole
B) double-pole
C) occupancy
D) combination
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
24
__________ are the most often used type of overcurrent protection device used in residential wiring.

A) Circuit breakers
B) Edison base fuses
C) Plug fuses
D) Cartridge fuses
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
25
__________ plug fuses are considered non-tamperable and are used in new installations requiring plug fuses.

A) Edison base
B) Type S
C) Cartridge
D) Plug
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
26
Almost all 15- or 20-amp, 125-volt receptacles in a house must be __________.

A) tamper-resistant
B) terminated
C) color-coded
D) self-grounding
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
27
Type __________ cable is used for underground service entrance installations.

A) SE
B) UF
C) USE
D) NM-B
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
28
Which of the following switches has ON/OFF marked on the switch handle?

A) Three-way
B) Double-pole
C) Four-way
D) None of the above
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
29
CO/ALR marked on a receptacle indicates that __________ conductors may be terminated to it.

A) copper
B) copper-clad aluminum
C) aluminum
D) All of the above
E) A and B only
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
30
The NEC requires rigid metal conduit to be supported within __________ feet of each box and then no more than every __________ feet thereafter. (general rule)

A) 3, 8
B) 5, 10
C) 2, 10
D) 3, 10
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
31
The ______ is the device that is inserted into a receptacle to establish a connection between the conductors of the attached flexible cord and the conductors connected to the receptacle.

A) outlet
B) fuse
C) connector
D) attachment plug
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
32
Romex is a trade name used by electricians to refer to __________.

A) armored cable
B) metal clad cable
C) underground feeder cable
D) nonmetallic sheathed cable
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
33
A _____ is described as a factory assembly of two or more conductors that has an overall outer sheathing that can be nonmetallic or metallic.

A) wire
B) conductor
C) cable
D) None of the above
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
34
If a switching device has the marking CU ONLY on it, an electrician can use only __________ wire with the device.

A) copper
B) copper clad aluminum
C) aluminum
D) any of the above
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
35
When two or more electrical device boxes are joined together for the purpose of holding more than one device it is called __________.

A) fitting
B) ganging
C) sticking
D) boxing
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
36
A weatherproof enclosure designed to give protection from falling dirt, rain, snow, sleet, and windblown dust is classified as a _____ enclosure and will need to be installed for outside appliciations.

A) NEMA 1
B) NEMA 2
C) NEMA 3R
D) NEMA 12
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
37
The ____________________ of a conductor refers to its ability to carry current.
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
38
The ungrounded 'hot' conductor is terminated to the __________ terminal on a duplex receptacle.

A) brass
B) silver
C) green
D) black
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
39
A part of an electrical box that is designed to be removed so that a cable or raceway can be connected to the box is called a __________.

A) knockout
B) mounting bracket
C) cable clamp
D) plaster ear
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
40
A _____ is a type of electrical panel that contains the main disconnecting means for the residential service entrance as well as the fuses or circuit breakers used to protect circuits and equipment like electric water heaters, ranges, dryers, and lighting.

A) safety switch
B) loadcenter
C) sub-panel
D) meter socket
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
41
In residential wiring, the NEC requires a ____________________-amp circuit breaker or fuse to be used with 12 AWG copper conductors.
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
42
A single-pole breaker is used on a circuit voltage of ____________________ volts and a two-pole breaker is used on a circuit voltage of ____________________ volts in residential wiring.
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
43
Electricians often refer to Type AC cable as ____________________ cable.
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
44
In certain locations in the United States, the AHJ may not allow nonmetallic sheathed cable in residential construction. The alternative wiring method most often used is _____________.
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
45
A(n) ____________________ is a point on the wiring system at which current is taken to supply equipment.
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
46
Explain the purpose of an antioxidant in electrical wiring.
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
47
_________________________ plug fuses cannot be used in new installations.
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
48
Explain when three-way switches are used in a residential lighting circuit.
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
49
____________________ is a measure of how much a fastener is being tightened and is measured in foot-pounds or inch-pounds.
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
50
A ____________________ is an overcurrent device that opens a circuit when a fusible link is melted away by the extreme heat caused by an overcurrent.
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
51
____________________ devices are used when more than one device is needed at one location.
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
52
Explain how a product gets listed.
Unlock Deck
Unlock for access to all 52 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 52 flashcards in this deck.