Deck 15: Electric Motors and Starting Components

Full screen (f)
exit full mode
Question
The start winding should drop out of the circuit once the motor has reached about __________% of its rated speed.

A) 50
B) 70
C) 90
D) 100
Use Space or
up arrow
down arrow
to flip the card.
Question
Capacitors are rated in which of the following?

A) ohms
B) watts
C) microfarads
D) microns
Question
The run winding has fewer turns than the start winding on a split-phase motor.
Question
ECM motors are less efficient than PSC motors.
Question
Which type of motor does not require the use of start components?

A) shaded-pole
B) PSC
C) CSCR
D) three-phase
E) both a and d
Question
Start capacitors are filled with oil and enclosed in a metal case.
Question
A start capacitor is wired in __________ with the start winding of an electric motor.

A) series
B) parallel
C) either series or parallel
D) neither series nor parallel
Question
Run capacitors are filled with oil and are enclosed in a metal case.
Question
Single-phase motors have __________ windings.

A) 1
B) 2
C) 3
D) 4
Question
The windings are located in which part of the motor?

A) rotor
B) stator
C) either a or b
D) it depends on the type of motor
Question
Which split-phase motor has the lowest starting torque?

A) PSC
B) CSIR
C) CSCR
D) three-phase
Question
Some three-phase motors can operate on 220 and 440 volts.
Question
When a split-phase motor is starting, both the start and run windings must be energized.
Question
Shaded-pole motors are rated in __________.

A) watts
B) horsepower
C) tons
D) Btus
Question
Shaded-pole motors have no start and run windings.
Question
The start winding on a split-phase motor has a lower resistance than the run winding..
Question
The LRA of an electric motor is approximately __________ times that of the RLA.

A) 2
B) 5
C) 7
D) 10
Question
Three-phase motors can be 120 volts.
Question
The phase angle on a split-phase motor is about __________ degrees.

A) 10
B) 20
C) 30
D) 40
Question
When a split-phase motor is running, both the start and run windings must be energized.
Question
The power factor of resistive circuits is 1, so the power that is produced is calculated by what formula?
Question
If the power factor in an inductive circuit is 0.5, the voltage is 100 volts and the amperage is 5 amps, the calculated power will be __________.
Question
List five types of electric motors commonly found in HVAC equipment.
Question
The positive temperature coefficient (PTC) is a __________, or variable resistance device, whose resistance __________ as the sensed temperature increases. When cool, the resistance of the device is very __________. When cool, both the start and run windings of the motor are in the __________ electric circuit and __________ voltage is being supplied to the start winding.
Question
The coil of a current magnetic relay is wired:

A) in series with the start winding.
B) in series with the run winding.
C) in parallel with the common winding.
D) in parallel with the run winding.
Question
Which phase angle is generated by a three-phase motor?

A) 30
B) 90
C) 120
D) 180
Question
List three devices used to remove the start winding from the circuit after the motor has started.
Question
What do the following acronyms stand for when referring to electric motors? LRA RLA FLA
Question
When checking resistance on a split-phase motor, common-to-run will be the __________ ohm reading, common-to-start will be the __________ ohm reading, and start-to-run will be the __________ ohm reading.

A) high, medium, low
B) low, medium, high
C) medium, low, high
D) medium, high, low
Question
Energy efficient systems often incorporate __________ motors to turn the system blowers and fans. These motors are very unique. They are powered by __________ power, but actually operate as __________ motors.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/30
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 15: Electric Motors and Starting Components
1
The start winding should drop out of the circuit once the motor has reached about __________% of its rated speed.

A) 50
B) 70
C) 90
D) 100
B
2
Capacitors are rated in which of the following?

A) ohms
B) watts
C) microfarads
D) microns
C
3
The run winding has fewer turns than the start winding on a split-phase motor.
True
4
ECM motors are less efficient than PSC motors.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
5
Which type of motor does not require the use of start components?

A) shaded-pole
B) PSC
C) CSCR
D) three-phase
E) both a and d
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
6
Start capacitors are filled with oil and enclosed in a metal case.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
7
A start capacitor is wired in __________ with the start winding of an electric motor.

A) series
B) parallel
C) either series or parallel
D) neither series nor parallel
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
8
Run capacitors are filled with oil and are enclosed in a metal case.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
9
Single-phase motors have __________ windings.

A) 1
B) 2
C) 3
D) 4
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
10
The windings are located in which part of the motor?

A) rotor
B) stator
C) either a or b
D) it depends on the type of motor
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
11
Which split-phase motor has the lowest starting torque?

A) PSC
B) CSIR
C) CSCR
D) three-phase
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
12
Some three-phase motors can operate on 220 and 440 volts.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
13
When a split-phase motor is starting, both the start and run windings must be energized.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
14
Shaded-pole motors are rated in __________.

A) watts
B) horsepower
C) tons
D) Btus
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
15
Shaded-pole motors have no start and run windings.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
16
The start winding on a split-phase motor has a lower resistance than the run winding..
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
17
The LRA of an electric motor is approximately __________ times that of the RLA.

A) 2
B) 5
C) 7
D) 10
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
18
Three-phase motors can be 120 volts.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
19
The phase angle on a split-phase motor is about __________ degrees.

A) 10
B) 20
C) 30
D) 40
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
20
When a split-phase motor is running, both the start and run windings must be energized.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
21
The power factor of resistive circuits is 1, so the power that is produced is calculated by what formula?
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
22
If the power factor in an inductive circuit is 0.5, the voltage is 100 volts and the amperage is 5 amps, the calculated power will be __________.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
23
List five types of electric motors commonly found in HVAC equipment.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
24
The positive temperature coefficient (PTC) is a __________, or variable resistance device, whose resistance __________ as the sensed temperature increases. When cool, the resistance of the device is very __________. When cool, both the start and run windings of the motor are in the __________ electric circuit and __________ voltage is being supplied to the start winding.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
25
The coil of a current magnetic relay is wired:

A) in series with the start winding.
B) in series with the run winding.
C) in parallel with the common winding.
D) in parallel with the run winding.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
26
Which phase angle is generated by a three-phase motor?

A) 30
B) 90
C) 120
D) 180
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
27
List three devices used to remove the start winding from the circuit after the motor has started.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
28
What do the following acronyms stand for when referring to electric motors? LRA RLA FLA
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
29
When checking resistance on a split-phase motor, common-to-run will be the __________ ohm reading, common-to-start will be the __________ ohm reading, and start-to-run will be the __________ ohm reading.

A) high, medium, low
B) low, medium, high
C) medium, low, high
D) medium, high, low
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
30
Energy efficient systems often incorporate __________ motors to turn the system blowers and fans. These motors are very unique. They are powered by __________ power, but actually operate as __________ motors.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 30 flashcards in this deck.