Deck 18: Electric Codes

Full screen (f)
exit full mode
Question
It is encouraged that the NEC be used as a design manual.
Use Space or
up arrow
down arrow
to flip the card.
Question
___________ concerns branch circuits.

A) Article 110
B) Article 210
C) Article 240
D) Article 250
Question
__________ provides information regarding general requirements for electrical installations.

A) Article 110
B) Article 210
C) Article 240
D) Article 250
Question
The term __________ is used to describe voltage levels between 50 Volts and 600 Volts.

A) average voltage
B) high voltage
C) line voltage
D) low voltage
Question
The __________ provides detailed information regarding many factors that affect electrical installations, maintenance and electrical system design and layout.

A) National Electricity Commission (NEC)
B) National Electricity Constitution (NEC)
C) National Electric Code (NEC)
D) National Fire Protection Association (NFPA)
Question
Match between columns
covers a wide range of topics regarding electrical boxes and conduit bodies that are used for electrical junctions, outlets and electrical devices
Article 424
covers a wide range of topics regarding electrical boxes and conduit bodies that are used for electrical junctions, outlets and electrical devices
Article 440
covers a wide range of topics regarding electrical boxes and conduit bodies that are used for electrical junctions, outlets and electrical devices
Article 422
covers a wide range of topics regarding electrical boxes and conduit bodies that are used for electrical junctions, outlets and electrical devices
Article 430
covers a wide range of topics regarding electrical boxes and conduit bodies that are used for electrical junctions, outlets and electrical devices
Article 314
Question
Receptacles need to be rated at amperages __________ the amperage rating of the branch circuit.

A) higher than
B) higher than or equal to
C) lower than
D) lower than or equal to
Question
It is never acceptable for the technician to cut the ground prong off any plug, extension cord, power cord, or appliance power cable.
Question
Permissive rules identify practices that are allowed, but not required.
Question
__________ concerns overcurrent protection.

A) Article 110
B) Article 210
C) Article 240
D) Article 250
Question
__________ provides information regarding proper grounding of tools and equipment.

A) Article 110
B) Article 210
C) Article 240
D) Article 250
Question
The NEC is intended to be used by untrained individuals.
Question
Mandatory rules identify practices that are either allowed or not allowed.
Question
Match between columns
provides useful information regarding the safe and proper methods to be used when installing, maintaining and servicing electric motors and their associated components
Article 424
provides useful information regarding the safe and proper methods to be used when installing, maintaining and servicing electric motors and their associated components
Article 440
provides useful information regarding the safe and proper methods to be used when installing, maintaining and servicing electric motors and their associated components
Article 422
provides useful information regarding the safe and proper methods to be used when installing, maintaining and servicing electric motors and their associated components
Article 430
provides useful information regarding the safe and proper methods to be used when installing, maintaining and servicing electric motors and their associated components
Article 314
Question
Match between columns
specifies that appliances are not to have any exposed live parts.
Article 424
specifies that appliances are not to have any exposed live parts.
Article 440
specifies that appliances are not to have any exposed live parts.
Article 422
specifies that appliances are not to have any exposed live parts.
Article 430
specifies that appliances are not to have any exposed live parts.
Article 314
Question
Match between columns
applies to motor-driven air conditioning and refrigeration systems as well as the branch circuits and controllers used in conjunction with this equipment
Article 424
applies to motor-driven air conditioning and refrigeration systems as well as the branch circuits and controllers used in conjunction with this equipment
Article 440
applies to motor-driven air conditioning and refrigeration systems as well as the branch circuits and controllers used in conjunction with this equipment
Article 422
applies to motor-driven air conditioning and refrigeration systems as well as the branch circuits and controllers used in conjunction with this equipment
Article 430
applies to motor-driven air conditioning and refrigeration systems as well as the branch circuits and controllers used in conjunction with this equipment
Article 314
Question
Match between columns
is devoted to electric heat and its unique requirements
Article 424
is devoted to electric heat and its unique requirements
Article 440
is devoted to electric heat and its unique requirements
Article 422
is devoted to electric heat and its unique requirements
Article 430
is devoted to electric heat and its unique requirements
Article 314
Question
Match between columns
communications systems
Chapters 5-7
communications systems
Chapter 9
communications systems
Chapters 1-4
communications systems
Chapter 8
Question
The reason for properly grounding tools and equipment is simple. If the insulation on a conductor becomes damaged or an energized conductor comes loose from a terminal connection in a piece of equipment, it is possible to __________ the surfaces that these conductors come in contact with. If the equipment is not properly grounded and someone comes in contact with an electrified surface, __________ or __________ could occur.
Question
__________ are required on all 15 and 20-amp, 125-volt receptacle circuits located in bathrooms, in garages, outdoors, in kitchens near countertops, and near laundry and utility sinks.
Question
Match between columns
general wiring practices and equipment
Chapters 5-7
general wiring practices and equipment
Chapter 9
general wiring practices and equipment
Chapters 1-4
general wiring practices and equipment
Chapter 8
Question
According to Article 300 of the NEC, it is permissible to run cables through holes that have been made in beams, rafters, joists or other wood members. However, the hole that has been made must be no closer than __________ inches from the edge of the wood member. If this amount of clearance cannot be maintained, the cable must be protected from damage by a __________ at least 1/16 of an inch thick
Question
According to Article 110 of the NEC, unused openings on equipment must be __________. The sealed opening must provide the same protection as the __________. A __________ is commonly used to close unused openings in electrical boxes
Question
__________ is the current, in amperes, that a conductor can continuously safely carry.
Question
List three common conductor types that are used in dry or damp locations
Question
According to Article 250 of the NEC, motors that are mounted with rubber or other insulating materials that isolate them from the metallic chassis of the equipment need to have a __________ between the motor and the equipment chassis
Question
List four NFPA codes that affect the residential construction industry.
Question
Phrases that identify mandatory rules include__________ and __________. Phrases that identify permissive rules include __________ and __________.
Question
__________ conductors are conductors that have no covering at all. __________ conductors are those conductors that have a covering that is recognized by the NEC as electrical insulation. __________ conductors are those conductors that have a covering that is not recognized by the NEC as electrical insulation.
Question
According to Article 110 of the NEC, if openings in nonmetallic boxes are removed and not used, the entire box must be __________.
Question
According to Article 240 of the NEC, overcurrent protection for ungrounded conductors are to be located at the point where __________.
Question
General purpose branch circuits supply power to two or more outlets for __________ and __________ use.
Question
Match between columns
applicable tables
Chapters 5-7
applicable tables
Chapter 9
applicable tables
Chapters 1-4
applicable tables
Chapter 8
Question
Match between columns
special conditions
Chapters 5-7
special conditions
Chapter 9
special conditions
Chapters 1-4
special conditions
Chapter 8
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/34
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 18: Electric Codes
1
It is encouraged that the NEC be used as a design manual.
False
2
___________ concerns branch circuits.

A) Article 110
B) Article 210
C) Article 240
D) Article 250
B
3
__________ provides information regarding general requirements for electrical installations.

A) Article 110
B) Article 210
C) Article 240
D) Article 250
A
4
The term __________ is used to describe voltage levels between 50 Volts and 600 Volts.

A) average voltage
B) high voltage
C) line voltage
D) low voltage
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
5
The __________ provides detailed information regarding many factors that affect electrical installations, maintenance and electrical system design and layout.

A) National Electricity Commission (NEC)
B) National Electricity Constitution (NEC)
C) National Electric Code (NEC)
D) National Fire Protection Association (NFPA)
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
6
Match between columns
covers a wide range of topics regarding electrical boxes and conduit bodies that are used for electrical junctions, outlets and electrical devices
Article 424
covers a wide range of topics regarding electrical boxes and conduit bodies that are used for electrical junctions, outlets and electrical devices
Article 440
covers a wide range of topics regarding electrical boxes and conduit bodies that are used for electrical junctions, outlets and electrical devices
Article 422
covers a wide range of topics regarding electrical boxes and conduit bodies that are used for electrical junctions, outlets and electrical devices
Article 430
covers a wide range of topics regarding electrical boxes and conduit bodies that are used for electrical junctions, outlets and electrical devices
Article 314
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
7
Receptacles need to be rated at amperages __________ the amperage rating of the branch circuit.

A) higher than
B) higher than or equal to
C) lower than
D) lower than or equal to
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
8
It is never acceptable for the technician to cut the ground prong off any plug, extension cord, power cord, or appliance power cable.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
9
Permissive rules identify practices that are allowed, but not required.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
10
__________ concerns overcurrent protection.

A) Article 110
B) Article 210
C) Article 240
D) Article 250
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
11
__________ provides information regarding proper grounding of tools and equipment.

A) Article 110
B) Article 210
C) Article 240
D) Article 250
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
12
The NEC is intended to be used by untrained individuals.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
13
Mandatory rules identify practices that are either allowed or not allowed.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
14
Match between columns
provides useful information regarding the safe and proper methods to be used when installing, maintaining and servicing electric motors and their associated components
Article 424
provides useful information regarding the safe and proper methods to be used when installing, maintaining and servicing electric motors and their associated components
Article 440
provides useful information regarding the safe and proper methods to be used when installing, maintaining and servicing electric motors and their associated components
Article 422
provides useful information regarding the safe and proper methods to be used when installing, maintaining and servicing electric motors and their associated components
Article 430
provides useful information regarding the safe and proper methods to be used when installing, maintaining and servicing electric motors and their associated components
Article 314
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
15
Match between columns
specifies that appliances are not to have any exposed live parts.
Article 424
specifies that appliances are not to have any exposed live parts.
Article 440
specifies that appliances are not to have any exposed live parts.
Article 422
specifies that appliances are not to have any exposed live parts.
Article 430
specifies that appliances are not to have any exposed live parts.
Article 314
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
16
Match between columns
applies to motor-driven air conditioning and refrigeration systems as well as the branch circuits and controllers used in conjunction with this equipment
Article 424
applies to motor-driven air conditioning and refrigeration systems as well as the branch circuits and controllers used in conjunction with this equipment
Article 440
applies to motor-driven air conditioning and refrigeration systems as well as the branch circuits and controllers used in conjunction with this equipment
Article 422
applies to motor-driven air conditioning and refrigeration systems as well as the branch circuits and controllers used in conjunction with this equipment
Article 430
applies to motor-driven air conditioning and refrigeration systems as well as the branch circuits and controllers used in conjunction with this equipment
Article 314
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
17
Match between columns
is devoted to electric heat and its unique requirements
Article 424
is devoted to electric heat and its unique requirements
Article 440
is devoted to electric heat and its unique requirements
Article 422
is devoted to electric heat and its unique requirements
Article 430
is devoted to electric heat and its unique requirements
Article 314
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
18
Match between columns
communications systems
Chapters 5-7
communications systems
Chapter 9
communications systems
Chapters 1-4
communications systems
Chapter 8
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
19
The reason for properly grounding tools and equipment is simple. If the insulation on a conductor becomes damaged or an energized conductor comes loose from a terminal connection in a piece of equipment, it is possible to __________ the surfaces that these conductors come in contact with. If the equipment is not properly grounded and someone comes in contact with an electrified surface, __________ or __________ could occur.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
20
__________ are required on all 15 and 20-amp, 125-volt receptacle circuits located in bathrooms, in garages, outdoors, in kitchens near countertops, and near laundry and utility sinks.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
21
Match between columns
general wiring practices and equipment
Chapters 5-7
general wiring practices and equipment
Chapter 9
general wiring practices and equipment
Chapters 1-4
general wiring practices and equipment
Chapter 8
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
22
According to Article 300 of the NEC, it is permissible to run cables through holes that have been made in beams, rafters, joists or other wood members. However, the hole that has been made must be no closer than __________ inches from the edge of the wood member. If this amount of clearance cannot be maintained, the cable must be protected from damage by a __________ at least 1/16 of an inch thick
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
23
According to Article 110 of the NEC, unused openings on equipment must be __________. The sealed opening must provide the same protection as the __________. A __________ is commonly used to close unused openings in electrical boxes
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
24
__________ is the current, in amperes, that a conductor can continuously safely carry.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
25
List three common conductor types that are used in dry or damp locations
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
26
According to Article 250 of the NEC, motors that are mounted with rubber or other insulating materials that isolate them from the metallic chassis of the equipment need to have a __________ between the motor and the equipment chassis
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
27
List four NFPA codes that affect the residential construction industry.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
28
Phrases that identify mandatory rules include__________ and __________. Phrases that identify permissive rules include __________ and __________.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
29
__________ conductors are conductors that have no covering at all. __________ conductors are those conductors that have a covering that is recognized by the NEC as electrical insulation. __________ conductors are those conductors that have a covering that is not recognized by the NEC as electrical insulation.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
30
According to Article 110 of the NEC, if openings in nonmetallic boxes are removed and not used, the entire box must be __________.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
31
According to Article 240 of the NEC, overcurrent protection for ungrounded conductors are to be located at the point where __________.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
32
General purpose branch circuits supply power to two or more outlets for __________ and __________ use.
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
33
Match between columns
applicable tables
Chapters 5-7
applicable tables
Chapter 9
applicable tables
Chapters 1-4
applicable tables
Chapter 8
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
34
Match between columns
special conditions
Chapters 5-7
special conditions
Chapter 9
special conditions
Chapters 1-4
special conditions
Chapter 8
Unlock Deck
Unlock for access to all 34 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 34 flashcards in this deck.