Deck 22: Electrical Troubleshooting
1
When checking a relay coil with an ohmmeter, an open coil would read __________ ohms.
A) infinite
B) 0
C) 100
D) 1000
A) infinite
B) 0
C) 100
D) 1000
A
2
Low- and high-pressure controls are physically located on which piece of equipment?
A) condensing unit
B) air handler
C) either a or b
D) neither a nor b
A) condensing unit
B) air handler
C) either a or b
D) neither a nor b
A
3
Which component on the low-voltage circuit of a residential HVAC system is NOT a switch?
A) thermostat contacts
B) high-pressure control
C) fan relay coil
D) fan relay contacts
A) thermostat contacts
B) high-pressure control
C) fan relay coil
D) fan relay contacts
C
4
When an air conditioning system has been pumped down, which component is not isolated?
A) evaporator
B) filter/drier
C) TXV
D) compressor
A) evaporator
B) filter/drier
C) TXV
D) compressor
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
5
When diagnosing the control circuit on the thermostat subbase, between which two terminals would a jumper wire be placed to check the fan circuit?
A) R and G
B) R and W
C) R and Y
D) G and Y
A) R and G
B) R and W
C) R and Y
D) G and Y
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
6
A high-pressure control closes on a pressure drop.
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
7
When checking a fuse on a 24-volt power supply with a voltmeter, if the fuse is blown, __________ volts will be read across the fuse.
A) 0
B) 24
C) 48
D) 115
A) 0
B) 24
C) 48
D) 115
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
8
When checking the secondary of a low-voltage transformer with an ohmmeter, if the transformer secondary is open it will read __________ ohms.
A) infinite
B) 0
C) 100
D) 1000
A) infinite
B) 0
C) 100
D) 1000
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
9
When troubleshooting a residential air conditioning system, the technician turns the fan switch to ON and nothing happens. What is the most likely problem?
A) defective subbase
B) defective fan motor
C) defective fan control
D) any of the above
A) defective subbase
B) defective fan motor
C) defective fan control
D) any of the above
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
10
When diagnosing the control circuit at the thermostat subbase, between which two terminals would a jumper wire be placed to check operation of the cooling circuit?
A) R and G
B) R and W
C) R and Y
D) G and Y
A) R and G
B) R and W
C) R and Y
D) G and Y
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
11
When checking a relay coil with an ohmmeter, the coil will read __________ ohms if the coil is shorted.
A) infinite
B) 0
C) 100
D) 1000
A) infinite
B) 0
C) 100
D) 1000
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
12
Which component on the low-voltage circuit of a residential HVAC system is NOT a load?
A) heat anticipator
B) thermostat contacts
C) fan relay coil
D) low-pressure control
A) heat anticipator
B) thermostat contacts
C) fan relay coil
D) low-pressure control
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
13
Many older thermostats contain mercury, so the technician must be sure to dispose of them properly.
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
14
A low-pressure control closes on pressure drop.
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
15
While troubleshooting a residential air conditioning system, the technician reads 24 volts across the compressor contactor coil, but the contactor does not energize. What is the most likely problem?
A) defective transformer
B) defective contactor contacts
C) defective contactor coil
D) high-voltage fuse blown
A) defective transformer
B) defective contactor contacts
C) defective contactor coil
D) high-voltage fuse blown
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
16
When diagnosing the control circuit at the thermostat subbase, between which two terminals would a jumper wire be placed to check the heating circuit?
A) R and G
B) R and W
C) R and Y
D) G and Y
A) R and G
B) R and W
C) R and Y
D) G and Y
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
17
How many amps should a low-voltage fuse be rated for to protect the secondary of a low-voltage transformer used in a residential HVAC system?
A) 1
B) 3
C) 5
D) 7
A) 1
B) 3
C) 5
D) 7
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
18
Low- and high-pressure controls are typically located on the __________-voltage side of the circuit.
A) low
B) high
C) either a or b
D) neither a nor b
A) low
B) high
C) either a or b
D) neither a nor b
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
19
When pumping down a residential central air conditioning system, which valve should be front seated?
A) liquid line
B) discharge line
C) suction line
D) all of the above
A) liquid line
B) discharge line
C) suction line
D) all of the above
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
20
If a low-pressure switch has opened on a residential air conditioning system, it is usually an indication of a defective low-pressure control.
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
21
When troubleshooting a residential air conditioning system, the technician reads 24 volts across the high-pressure control. What would be the most likely problem?
A) defective high-pressure control
B) dirty condenser
C) defective compressor
D) defective transformer
A) defective high-pressure control
B) dirty condenser
C) defective compressor
D) defective transformer
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
22
When troubleshooting a residential heating system, the technician reads 24 volts at the gas valve on a call for heat, but the gas valve does not energize. What would be the most likely problem?
A) defective gas valve
B) defective thermostat
C) defective transformer
D) blown low-voltage fuse
A) defective gas valve
B) defective thermostat
C) defective transformer
D) blown low-voltage fuse
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
23
List the four components that make up an electrical circuit.
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
24
When troubleshooting a residential heating system, the technician reads 24 volts across R and W on the furnace low-voltage terminal strip with the thermostat set to call for heating. What would be the most likely problem?
A) defective gas valve
B) defective transformer
C) blown high-voltage fuse
D) defective thermostat
A) defective gas valve
B) defective transformer
C) blown high-voltage fuse
D) defective thermostat
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
25
List four conclusions that can be made about a residential HVAC system when the fan switch is turned to "ON" and the fan motor starts.
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
26
When troubleshooting a residential air conditioning system, the technician notices the condenser fan motor operating, but the compressor is not. What is the most likely cause?
A) high-voltage circuit breaker for condensing unit is tripped
B) high-pressure switch is open
C) defective compressor
D) defective contactor
A) high-voltage circuit breaker for condensing unit is tripped
B) high-pressure switch is open
C) defective compressor
D) defective contactor
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck