Deck 7: Specialized Hvacr Tools
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Match between columns
Question
Match between columns
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Match between columns
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/43
Play
Full screen (f)
Deck 7: Specialized Hvacr Tools
1
The __________ is an essential tool used by the HVAC/R service technician to troubleshoot and evaluate the electric components of an air conditioning, heating or refrigeration system.
A) clamp-on ammeter (COA)
B) carbon monoxide tester (CO tester)
C) u-tube manometer (UTM)
D) volt-ohm milliammeter (VOM)
A) clamp-on ammeter (COA)
B) carbon monoxide tester (CO tester)
C) u-tube manometer (UTM)
D) volt-ohm milliammeter (VOM)
D
2
A __________ is used to measure very low pressures above the flame in a heating appliance to verify the flow of flue gases up a chimney or vent
A) draft gauge
B) pressure gauge
C) smoke tester
D) vacuum gauge
A) draft gauge
B) pressure gauge
C) smoke tester
D) vacuum gauge
A
3
The process of containing refrigerant that is removed from systems is called __________.
A) reconstituting
B) recouping
C) recovery
D) recycling
A) reconstituting
B) recouping
C) recovery
D) recycling
C
4
The stem thermometer is used to measure the temperature of __________.
A) the occupied space
B) the temperature of air in a duct system
C) a and b
D) neither a nor b
A) the occupied space
B) the temperature of air in a duct system
C) a and b
D) neither a nor b
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
5
It is illegal to intentionally release refrigerant from air conditioning or refrigeration systems to the atmosphere.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
6
POE lubricants are compatible with AB or mineral oils.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
7
__________ is the term used to describe a complete path between two points in an electric circuit.
A) Conduction
B) Connection
C) Continuity
D) Consumption
A) Conduction
B) Connection
C) Continuity
D) Consumption
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
8
Two common configurations of gauge manifolds are the two-valve manifold and the four-valve manifold. The valves are __________ when turned counter-clockwise and __________ when turned clockwise.
A) closed, open
B) open, closed
A) closed, open
B) open, closed
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
9
The center port on a four-valve manifold is marked VAC and is used for __________.
A) evacuation purposes
B) refrigerant recovery
C) system charging
D) system leak testing
A) evacuation purposes
B) refrigerant recovery
C) system charging
D) system leak testing
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
10
The ultrasonic leak detector uses a __________ to locate escaping refrigerant or nitrogen.
A) flame
B) light
C) microphone
D) pump
A) flame
B) light
C) microphone
D) pump
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
11
Thermistor thermometers often have multiple __________.
A) function settings
B) infrared sensors
C) probes
D) resistors
A) function settings
B) infrared sensors
C) probes
D) resistors
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
12
In order to ensure that the air conditioning system is properly charged, accurate pressure and temperature readings must be obtained, not only from the system itself, but also from __________.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
13
When the air conditioning and refrigeration technician uses the gauge manifold, he or she uses the saturation temperature on the high side of the system to help calculate __________ and the saturation temperature on the low side of the system to help calculate __________.
A) condenser subcooling, evaporator superheat
B) condenser superheat, evaporator subcooling
C) condenser supercooling, evaporator subheat
D) condenser cooling, evaporator heat
A) condenser subcooling, evaporator superheat
B) condenser superheat, evaporator subcooling
C) condenser supercooling, evaporator subheat
D) condenser cooling, evaporator heat
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
14
A __________ is used to determine the presence of unburned fuel in a sample of flue gases taken from an oil burner.
A) draft gauge
B) pressure gauge
C) smoke tester
D) vacuum gauge
A) draft gauge
B) pressure gauge
C) smoke tester
D) vacuum gauge
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
15
__________ are used to measure very low pressures and sometimes vacuums on air conditioning, heating and refrigeration systems.
A) Anometers
B) Manometers
C) Thermometers
D) Volt-ohm milliammeters
A) Anometers
B) Manometers
C) Thermometers
D) Volt-ohm milliammeters
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
16
Fossil fuel heating systems must be set up properly to ensure that they operate as intended. Improper fuel-air mixtures on a fossil fuel appliance can lead to what four problems?
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
17
The micron gauge is used to measure the level of vacuum reached during the evacuation process.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
18
Match between columns
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
19
Match between columns
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
20
Explain why it is important to investigate the uses and limitations of each type of thermometer before selecting the instrument to be used.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
21
The two-valve manifold has three hoses and two valves. The gauge is divided into two sides, the low side and the high side. The low side is comprised of the low side valve, the low side gauge and the low side hose, all of which are color-coded __________. The high side is comprised of the high side valve, the high side gauge and the high side hose, all of which are color-coded __________.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
22
__________ is the relationship that compares the amount of moisture contained in an air sample to the maximum amount of moisture that the sample can hold. __________ is simply the speed of the air, measured in feet per minute.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
23
The electronic leak detector uses a pump to pull air samples into the unit and test them for traces of __________.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
24
Taking temperature readings ranks among the most commonly performed tasks in our industry. A number of different types of thermometers are available. List three common thermometer types.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
25
Systems that operate with HCFC refrigerants, such as R-22, use __________ oil or __________ oil. Systems that operate with HFC refrigerants and HFC blends, such as R-410A, use __________ oil.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
26
The __________ leak detector operates with an open flame and indicates a refrigerant leak when the flame color changes from __________ to __________,
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
27
The __________ leak detector utilizes a fluorescent refrigerant dye that is added to, and circulated through, the system. The point of the leak is located as it glows when observed.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
28
The center hose on a two-valve manifold is color-coded __________. List the four pieces of equipment to which this hose can be connected.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
29
The vacuum pump is used to evacuate air conditioning and refrigeration systems. The process of evacuation involves the __________ and __________ of the system. Degassing involves the removal of air, nitrogen and other __________ from the system, while dehydration involves the removal of __________ from the system.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
30
Probably one of the most important tools the air conditioning and refrigeration technician uses is the gauge manifold. The manifold is made up of two gauges. One gauge, used to measure __________ and __________, is color-coded blue. The other gauge, used to measure __________, is color-coded red.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
31
A fin straightener, also commonly known as a __________, is used to straighten the aluminum fins on condenser or evaporator coils that have become bent or slightly damaged.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
32
The four-valve manifold has two center ports. The two center ports are labeled __________ and __________.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
33
The one main difference between the clamp-on meter and the VOM is that the clamp-on meter __________.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
34
Pressures measured by the manometer are measured in __________, where __________ = 1 psig.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
35
List five elements that can be measured by a combustion analyzer.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
36
The technician should always use a __________ when adding refrigerant to, or removing refrigerant from a system, as proper record keeping regarding refrigerant quantities added to, removed from, or leaking from systems is vital.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
37
The VOM is used to measure what four aspects of the electrics circuits in the air conditioning, heating or refrigeration system?
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
38
The refrigeration service wrench is used to turn __________ stems on system valves and tanks. Using this tool on such stems helps ensure that the stems do not get __________.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
39
The amperage mode on the VOM is not often used by the service technician because __________.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
40
A __________ snip can cut through multiple layers of metal. A __________ is used to remove V-shaped sections from a sheet of metal. A __________ is used to make sharp bends in pieces of sheet metal. __________ are used to create flanges on the end of a sheet metal section.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
41
Sheet metal hammers are easily identified as they have __________ heads and __________ edges.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
42
When laying out a sheet metal duct section, various tools are used to mark the metal prior to cutting. __________ are used to scratch straight lines on the metal. __________ are used to scratch arced lines and circles on the metal. __________ can be used to scratch freeform and straight lines on the metal surface.
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck
43
Match between columns
Unlock Deck
Unlock for access to all 43 flashcards in this deck.
Unlock Deck
k this deck

