Deck 13: Electrical Distribution

Full screen (f)
exit full mode
Question
Which frequency is a harmonic of 60 Hz?

A) 10 Hz
B) 30 Hz
C) 90 Hz
D) 180 Hz
Use Space or
up arrow
down arrow
to flip the card.
Question
Large industrial establishments may find it more economical to distribute power at voltages higher than 600 volts.
Question
It has been proven that currents as small as ____ through the heart, lungs, or brain can be fatal.

A) 15 mA
B) 50 mA
C) 1 A
D) 15 A
Question
Which type of ground-fault protection is generally used for three-wire, single-phase, and for three-phase installations?

A) GFP
B) GFCI
C) fuse
D) circuit breaker
Question
In a radial distribution system, the central station supplies power to the various ____.

A) substations
B) loops
C) residential units
D) industrial installations
Question
A loop distribution system is an electrical transmission system that begins at a central station and supplies power to various substations.
Question
Which NEC Article covers grounding locations and methods?

A) Article 79
B) Article 220
C) Article 250
D) Article 429
Question
What does the abbreviation GFP stand for?

A) Ground Fire Protection
B) Ground Fire Prevention
C) Ground Fault Protector
D) Ground Fault Prevention
Question
The purpose of grounding is to limit the magnitude of current surges.
Question
____ may be installed in a substation unit.

A) Branch circuit conductors
B) Isolation switches
C) Main supply conductors
D) Utility poles
Question
If the ungrounded (hot) conductor comes in contact with a metal enclosure that is not grounded, a ____ will be present between the enclosure and the ground.

A) current
B) voltage
C) resistance
D) reactance
Question
Most single-phase systems are supplied from a three-phase primary.
Question
The effect of a harmonic on the current flowing in the supply conductors is approximately ____ percent.

A) less than 1
B) 3-5
C) 10-20
D) 80-90
Question
The GFCI operates on the principle that an equal amount of current is flowing through the two wires.
Question
The effect of a harmonic on the current flowing in the neutral conductor is approximately ____ percent.

A) less than one
B) 3-5
C) 50
D) 90
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 13: Electrical Distribution
1
Which frequency is a harmonic of 60 Hz?

A) 10 Hz
B) 30 Hz
C) 90 Hz
D) 180 Hz
D
2
Large industrial establishments may find it more economical to distribute power at voltages higher than 600 volts.
True
3
It has been proven that currents as small as ____ through the heart, lungs, or brain can be fatal.

A) 15 mA
B) 50 mA
C) 1 A
D) 15 A
B
4
Which type of ground-fault protection is generally used for three-wire, single-phase, and for three-phase installations?

A) GFP
B) GFCI
C) fuse
D) circuit breaker
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
5
In a radial distribution system, the central station supplies power to the various ____.

A) substations
B) loops
C) residential units
D) industrial installations
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
6
A loop distribution system is an electrical transmission system that begins at a central station and supplies power to various substations.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
7
Which NEC Article covers grounding locations and methods?

A) Article 79
B) Article 220
C) Article 250
D) Article 429
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
8
What does the abbreviation GFP stand for?

A) Ground Fire Protection
B) Ground Fire Prevention
C) Ground Fault Protector
D) Ground Fault Prevention
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
9
The purpose of grounding is to limit the magnitude of current surges.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
10
____ may be installed in a substation unit.

A) Branch circuit conductors
B) Isolation switches
C) Main supply conductors
D) Utility poles
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
11
If the ungrounded (hot) conductor comes in contact with a metal enclosure that is not grounded, a ____ will be present between the enclosure and the ground.

A) current
B) voltage
C) resistance
D) reactance
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
12
Most single-phase systems are supplied from a three-phase primary.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
13
The effect of a harmonic on the current flowing in the supply conductors is approximately ____ percent.

A) less than 1
B) 3-5
C) 10-20
D) 80-90
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
14
The GFCI operates on the principle that an equal amount of current is flowing through the two wires.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
15
The effect of a harmonic on the current flowing in the neutral conductor is approximately ____ percent.

A) less than one
B) 3-5
C) 50
D) 90
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 15 flashcards in this deck.