Deck 13: Common Rail Fuel Systems

Full screen (f)
exit full mode
Question
Technician A says that a CR engine can vary the injection pressure, timing, and injection rate shape for each injector. Technician B says that the injection pressure is the same for all injectors in CR engines, and injectors can perform multiple injection events during each combustion cycle. Who is correct?

A)Technician A
B)Technician B
C)Both A and B
D)Neither A nor B
Use Space or
up arrow
down arrow
to flip the card.
Question
Technician A says that servo-hydraulic injector actuators use a small amount of control valve movement to control larger, more powerful, and faster-acting hydraulic forces. Technician B says that control valves that use piezoelectric technology are the only actuators capable of servo action. Who is correct?

A)Technician A
B)Technician B
C)Both A and B
D)Neither A nor B
Question
Technician A says that rate shaping involves changing the quantity of fuel as it is discharged from the injector spray holes. Technician B says that rate shaping requires multiple injection events and a high-pressure fuel system with the ability to vary injection pressure. Who is correct?

A)Technician A
B)Technician B
C)Both A and B
D)Neither A nor B
Question
Technician A says that cylinder misfires can be detected on CR engines by slightly cracking open the fuel line to each injector when the engine is running. Technician B says that it is important to place a shop towel over the injector when checking for misfires to prevent pressurized fuel from penetrating the skin. Who is correct?

A)Technician A
B)Technician B
C)Both A and B
D)Neither A nor B
Question
Consider a hydraulically balanced needle valve used in a first- or second-generation Bosch common rail (CR) injector. How would a drain orifice that is much larger than the inlet orifice affect its functioning?

A)Slower nozzle lift than closing.
B)Faster nozzle opening than closing.
C)Failure of the nozzle valve to lift.
D)Failure of the nozzle valve to close.
Question
Consider a non-amplified CR injector. If the injection control valve cannot close properly due to dirt or erosion of the valve seat, what is the most common result?

A)The injector cannot deliver any fuel.
B)The nozzle valve stays seated.
C)The nozzle valve remains open.
D)The flow control valve remains open.
Question
Consider a non-amplified CR injector. If the inlet restriction orifice to the pressure control chamber is plugged, what is the most likely to happen?

A)The injector cannot deliver any fuel.
B)The nozzle valve stays seated.
C)The nozzle valve remains open when the engine is running.
D)The flow control valve remains open.
Question
Consider a piezoelectric CR injector. What happens to the actuator when current is initially applied to the piezoceramic wafers?

A)The nozzle valve is seated by high-pressure fuel.
B)The crystals expand.
C)The crystals contract.
D)Reaction induction causes a delayed injector response time.
Question
Consider a CR3 system with a leaking fuel return line. Which of the following situations is the operator most likely to encounter?

A)A noise in the engine.
B)A cylinder misfire.
C)A no-start condition.
D)Low power.
Question
Consider a Bosch CRS2 system. The FCV on a CP-3 pump is open circuited. Which of the following conditions is most likely to be observed?

A)The engine won't start.
B)The engine runs rough.
C)The engine will only idle.
D)Very low engine power.
Question
Which Bosch CR system requires certified insulated gloves when working on the system with the ignition key in the On position?

A)CR1.
B)CR2.
C)CR3.
D)CR4.
Question
Technician A says that dirt bypassing the filter on some CR systems can cause an injector to stick open and continuously fuel a cylinder. Technician B says that any dirt particles may potentially damage the injector, but they would not allow an injector to full-fuel or cause the engine to run away. Who is correct?

A)Technician A
B)Technician B
C)Both A and B
D)Neither A nor B
Question
Technician A says that servo-hydraulic actuators that use electromagnets have better durability than piezoceramic actuators. Technician B says piezoceramic actuators are as durable as, if not more durable than, servo-hydraulic injectors that use electromagnets. Who is correct?

A)Technician A
B)Technician B
C)Both A and B
D)Neither A nor B
Question
Technician A says that CRI2 injectors will amplify injection pressure under heavy loads as needed by the engine. Technician B says that injection amplification takes place only in CR3 injectors. Who is correct?

A)Technician A
B)Technician B
C)Both A and B
D)Neither A nor B
Question
When performing a back leakage test on a CR engine with CRI2 injectors, excessive fuel flow from the fuel return line was measured from the cylinder head. Which of the following conditions is most likely the cause?

A)A worn-out high-pressure pump.
B)A defective fuel control valve.
C)A leaking quill tube connection.
D)A defective pressure-protection valve.
Question
Technician A says that faster-responding piezoelectric injectors are best suited for use in light-duty CR engines. Technician B says that engine speeds of automotive diesel do not require the piezoelectric injector's higher number of injection events. Who is correct?

A)Technician A
B)Technician B
C)Both A and B
D)Neither A nor B
Question
What typically happens to the length of the pulse width to the electronic fuel control valve (FCV) valve when fuel leaks from the high-pressure rail?

A)It remains the same.
B)It increases.
C)It decreases.
D)It increases, the suddenly decreases.
Question
While two technicians are discussing the purpose of a second electrical control valve, which regulates fuel volume supplied to the inlet of the high-pressure pump, Technician A says the VCV helps reduce fuel consumption. Technician B says the VCV is needed to reduce emissions. Who is correct?

A)Technician A
B)Technician B
C)Both A and B
D)Neither A nor B
Question
Which of the following is the most likely cause of excessive fuel return from the cylinder head of a CR engine?

A)Excessive injection pressure.
B)A nozzle valve that is stuck closed.
C)Eroded or pitted ball valve seats.
D)A plugged inlet orifice in one or more injectors.
Question
While performing a back leakage test for a second-generation Bosch CR fuel system, the fuel volume was measured to be above specification from the cylinder head. Technician A says the cause could be a leaking quill tube. Technician B says the cause could be one or more injectors with worn-out ball valve seats. Who is correct?

A)Technician A
B)Technician B
C)Both A and B
D)Neither A nor B
Question
Current system pressures for heavy-duty CR injection operate as high as:

A)10,000-17,500 psi
B)13,000-25,500 psi
C)30,000-37,500 psi
D)40 000-47 500 psi"
Question
Technician A says that modern HPCR (High Pressure Common Rail) fuel pressurization occurs in concert with engine speed. Technician B says that regardless of engine rotational speed and load, HPCR fuel-injection pressure can be electronically controlled to provide the optimal pressure required. Who is right?

A)A only"
B)B only"
C)Both A and B
D)Neither A nor B"
Question
Which of the following fuel systems was developed by Bosch and used by Detroit Diesel's ACR (Amplified Common Rail) system?

A)HADIS (Hydraulically Amplified Diesel-Injection System)"
B)HPCR (High Pressure Common Rail)"
C)HEUI (hydraulically actuated electronic unit injection)
D)EUI (Electronic Unit Injection) system"
Question
Which of the following terms refers to a control system that multiplies a small mechanical force or movement into a much greater force or movement?

A)Accumulator"
B)Piston"
C)Piezo
D)Servo"
Question
Currently, the fastest production servo-hydraulic CR injector can produce ___ separate injection events during one combustion cycle.

A)4"
B)5"
C)6
D)9"
Question
Which of the following is an essential element of rate shaping, which refers to the quantity of fuel injected per degree of crankshaft rotation?

A)Nozzle-valve lift"
B)Fuel rate"
C)Rate curve
D)Injection rate"
Question
Two technicians are describing common rail fuel system operation. Technician A says that electronically regulating the pressure in the high-pressure pump permits injection pressures to vary with speed and load conditions. Technician B says that a common rail stores fuel pressurized to match optimal injection pressure for any given engine speed or load condition. Who is right?

A)A only"
B)B only"
C)Both A and B
D)Neither A nor B"
Question
How many main types of CR injectors are there?

A)1"
B)2"
C)3
D)4"
Question
Which of the following operations is NOT used by Bosch CR1 and CR2 injectors to inject fuel?

A)Electrical signal is removed from the magnetic solenoid"
B)Servo-hydraulic valve closes"
C)Drain hole from the pressure control chamber opens
D)Rail pressure lifts the nozzle valve"
Question
In which of the following Bosch CRS2 injector stages does closing the drain orifice cause fuel pressure to build in the pressure chamber, forcing the control rod against the nozzle valve?

A)Pre-injection"
B)Beginning of injection"
C)End of Injection
D)Post-injection"
Question
The CRS1, which had limited use in Europe only, uses a single spring to return the armature to a resting position, whereas the CRS2 uses:

A)two springs"
B)three springs"
C)four springs
D)five springs"
Question
Two technicians are discussing piezoceramic injectors. Technician A says that piezo technology involves replacing magnetic solenoids with high speed solenoids. Technician B says that piezoelectric crystals enable much faster injector response than do magnetic actuators. Who is right?

A)A only"
B)B only"
C)Both A and B
D)Neither A nor B"
Question
In which of the 3rd generation Bosch Piezo CRS3 injector stages is the nozzle valve hydraulically balanced with high-pressure fuel from the rail applied to the top and bottom of the nozzle valve?

A)Beginning of Injection"
B)Pre-injection"
C)End of Injection
D)Resting"
Question
Consider a hydraulically balanced needle valve used in a first- or second-generation Bosch common rail (CR) injector. How would a drain orifice that is much larger than the inlet orifice affect its functioning?

A)Slower nozzle lift than closing."
B)Faster nozzle opening than closing."
C)Failure of the nozzle valve to lift.
D)Failure of the nozzle valve to close."
Question
What actuator technology is used with the Siemens VDO K16 pump?

A)Servo-hydraulic"
B)Spindle valve (amplified common rail (ACR))"
C)Ball valve
D)Piezoceramic"
Question
The Siemens CR injector uses a conventional six-hole nozzle valve that opens inward when the hydraulic balance of the nozzle valve is:

A)higher below the nozzle"
B)lower below the nozzle"
C)the same level as the nozzle
D)higher above the nozzle"
Question
Two technicians are explaining the Siemens injector operation. Technician A says that a piezoceramic actuator uses multiple stacked piezo crystal discs that expand longitudinally when electrically energized. Technician B says that fuel pressure in a chamber below the control piston regulates the movement of the control piston. Who is right?

A)A only"
B)B only"
C)Both A and B
D)Neither A nor B"
Question
At which stage of the Siemens injector operation does fuel pressurized by the high-pressure pump enter the fuel rail and is supplied to each injector fitting?

A)Post-Injection"
B)Pre-injection"
C)End of Injection
D)Injection"
Question
At which stage of the Siemens injector operation does the larger surface area above the control piston apply greater pressure than the force of the fuel against the nozzle-valve annulus?

A)Post-Injection"
B)Pre-injection"
C)End of Injection
D)Injection"
Question
At which stage of the Siemens injector operation does spring pressure close the mushroom valve, causing pressure to build in the control piston control chamber?

A)Post-Injection"
B)Pre-injection"
C)End of Injection
D)Injection"
Question
Technician A says that during the end of injection stage, the pressure in the control chamber forces the control piston downward against the nozzle valve, seating the nozzle valve and ending injection. Technician B says that the ECM de-energizes the piezoceramic actuator to cause a rapid return of the actuator to a resting position during the end of injection phase. Who is right?

A)A only"
B)B only"
C)Both A and B
D)Neither A nor B"
Question
Delphi claims the system can generate _____ reduction in emissions.

A)35% to 40%"
B)25% to 30%"
C)15% to 20%
D)45% to 50%"
Question
Injector adaptation to compensate for wear and deterioration is performed by an algorithm called:

A)speed pilot control (SPC)"
B)accelerometer pump control"
C)spindle valve (amplified common rail (ACR)
D)accelerometer pilot control"
Question
Two technicians are describing the Delphi Multec injector. Technician A says that the spindle valve used by Delphi nozzles is a servo-hydraulic actuator that uses the principles of hydraulic balance to rapidly open and close. Technician B says that the control valve also regulates the operation of a hydraulically balanced nozzle valve. Who is right?

A)A only"
B)B only"
C)Both A and B
D)Neither A nor B"
Question
The spindle valve used by Delphi nozzles is a ____ type of actuator that uses principles of hydraulic balance to open and close rapidly.

A)servo-hydraulic"
B)spindle valve (amplified common rail (ACR))"
C)ball valve
D)piezoceramic"
Question
The electric current supplied to Delphi's Multec solenoid CR injectors is at:

A)12 volts"
B)24 volts"
C)36 volts
D)112 volts"
Question
Each Delphi injector contains (a) laser printed:

A)dot matrix code"
B)pump compensation codes"
C)injector control codes
D)pump control codes"
Question
While two technicians are discussing the purpose of a second electrical control valve, which regulates fuel volume supplied to the inlet of the high-pressure pump, Technician A says the VCV helps reduce fuel consumption. Technician B says the VCV is needed to reduce emissions. Who is correct?

A)Technician A"
B)Technician B"
C)Both A and B
D)Neither A nor B"
Question
To reduce parasitic power losses produced by pumping fuel needlessly and to keep fuel temperatures low, pumps now use:

A)outlet pressure metering"
B)inlet pressure metering"
C)outlet volume metering
D)inlet volume metering"
Question
An electronically controlled fuel pressure regulator valve that varies pump _____ as commanded by the ECM regulates fuel supplied to the pump and maximum pump.

A)output pressure"
B)inlet pressure"
C)outlet volume
D)inlet volume"
Question
Which of the following is required for V engines to synchronize engine firing order with pump strokes?

A)1-piston pumps"
B)2-piston pumps"
C)4-piston pumps
D)8-piston pumps"
Question
Two technicians are describing pressure control components of common rail fuel. Technician A says if the high-pressure pump is removed, timing marks on the pump gear and camshaft gear are used to correctly time components during reinstallation. Technician B says that late-model high-pressure pumps are often timed so the peak pressure pulses are phased with the injection events. Who is right?

A)A only"
B)B only"
C)Both A and B
D)Neither A nor B"
Question
To which generation does the high-pressure pump that Bosch purchased from Fiat in the mid-1990s belong, which can develop pressure up to 19,845 psi and was used in the Unijet System?

A)Gen I"
B)Gen II"
C)Gen III
D)Gen IV"
Question
At what ratio to engine speed is the high-pressure CP-3 pump driven?

A)1:1"
B)2:1"
C)½ :1
D)4:1"
Question
While performing a back leakage test for a second-generation Bosch CR fuel system, the fuel volume was measured to be above specification from the cylinder head. Technician A says the cause could be a leaking quill tube. Technician B says the cause could be one or more injectors with worn-out ball valve seats. Who is correct?

A)Technician A"
B)Technician B"
C)Both A and B
D)Neither A nor B"
Question
Which of the following is NOT a strategy that can be used to identify faults on common rail systems?

A)Note the fuel mass"
B)Time the injection"
C)Control the fuel balance
D)Check the battery voltage"
Question
To monitor and maintain the emissions levels to their current standard, what legislation requires manufacturers to detect any potential malfunction that could cause emissions to rise above legislated standards?

A)OBDI"
B)OBDII"
C)OBDIII
D)OBDIV"
Question
Which of the following will cause an injector to leak or to stay open and inject fuel continuously?

A)Defective rail pressure sensor"
B)Fuel leak"
C)Defective high pressure pump
D)Worn eroded or dirty ball seat"
Question
Which one of the following is NOT a fuel return flow that can be measured to identify the faulty component?

A)Injector fuel return"
B)High-pressure pump return"
C)High-pressure relief valve return
D)Secondary filter return"
Question
Two technicians are describing measuring injector back leakage (method 1). Technician A says that you start and run the engine at idle, and for 5 minutes, measure and record the volume of fuel accumulating in the graduated cylinders. Technician B says that generally, a defective injector will flow three times the minimum return rate. Who is right?

A)A only"
B)B only"
C)Both A and B
D)Neither A nor B"
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/60
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 13: Common Rail Fuel Systems
1
Technician A says that a CR engine can vary the injection pressure, timing, and injection rate shape for each injector. Technician B says that the injection pressure is the same for all injectors in CR engines, and injectors can perform multiple injection events during each combustion cycle. Who is correct?

A)Technician A
B)Technician B
C)Both A and B
D)Neither A nor B
B
2
Technician A says that servo-hydraulic injector actuators use a small amount of control valve movement to control larger, more powerful, and faster-acting hydraulic forces. Technician B says that control valves that use piezoelectric technology are the only actuators capable of servo action. Who is correct?

A)Technician A
B)Technician B
C)Both A and B
D)Neither A nor B
A
3
Technician A says that rate shaping involves changing the quantity of fuel as it is discharged from the injector spray holes. Technician B says that rate shaping requires multiple injection events and a high-pressure fuel system with the ability to vary injection pressure. Who is correct?

A)Technician A
B)Technician B
C)Both A and B
D)Neither A nor B
C
4
Technician A says that cylinder misfires can be detected on CR engines by slightly cracking open the fuel line to each injector when the engine is running. Technician B says that it is important to place a shop towel over the injector when checking for misfires to prevent pressurized fuel from penetrating the skin. Who is correct?

A)Technician A
B)Technician B
C)Both A and B
D)Neither A nor B
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
5
Consider a hydraulically balanced needle valve used in a first- or second-generation Bosch common rail (CR) injector. How would a drain orifice that is much larger than the inlet orifice affect its functioning?

A)Slower nozzle lift than closing.
B)Faster nozzle opening than closing.
C)Failure of the nozzle valve to lift.
D)Failure of the nozzle valve to close.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
6
Consider a non-amplified CR injector. If the injection control valve cannot close properly due to dirt or erosion of the valve seat, what is the most common result?

A)The injector cannot deliver any fuel.
B)The nozzle valve stays seated.
C)The nozzle valve remains open.
D)The flow control valve remains open.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
7
Consider a non-amplified CR injector. If the inlet restriction orifice to the pressure control chamber is plugged, what is the most likely to happen?

A)The injector cannot deliver any fuel.
B)The nozzle valve stays seated.
C)The nozzle valve remains open when the engine is running.
D)The flow control valve remains open.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
8
Consider a piezoelectric CR injector. What happens to the actuator when current is initially applied to the piezoceramic wafers?

A)The nozzle valve is seated by high-pressure fuel.
B)The crystals expand.
C)The crystals contract.
D)Reaction induction causes a delayed injector response time.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
9
Consider a CR3 system with a leaking fuel return line. Which of the following situations is the operator most likely to encounter?

A)A noise in the engine.
B)A cylinder misfire.
C)A no-start condition.
D)Low power.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
10
Consider a Bosch CRS2 system. The FCV on a CP-3 pump is open circuited. Which of the following conditions is most likely to be observed?

A)The engine won't start.
B)The engine runs rough.
C)The engine will only idle.
D)Very low engine power.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
11
Which Bosch CR system requires certified insulated gloves when working on the system with the ignition key in the On position?

A)CR1.
B)CR2.
C)CR3.
D)CR4.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
12
Technician A says that dirt bypassing the filter on some CR systems can cause an injector to stick open and continuously fuel a cylinder. Technician B says that any dirt particles may potentially damage the injector, but they would not allow an injector to full-fuel or cause the engine to run away. Who is correct?

A)Technician A
B)Technician B
C)Both A and B
D)Neither A nor B
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
13
Technician A says that servo-hydraulic actuators that use electromagnets have better durability than piezoceramic actuators. Technician B says piezoceramic actuators are as durable as, if not more durable than, servo-hydraulic injectors that use electromagnets. Who is correct?

A)Technician A
B)Technician B
C)Both A and B
D)Neither A nor B
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
14
Technician A says that CRI2 injectors will amplify injection pressure under heavy loads as needed by the engine. Technician B says that injection amplification takes place only in CR3 injectors. Who is correct?

A)Technician A
B)Technician B
C)Both A and B
D)Neither A nor B
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
15
When performing a back leakage test on a CR engine with CRI2 injectors, excessive fuel flow from the fuel return line was measured from the cylinder head. Which of the following conditions is most likely the cause?

A)A worn-out high-pressure pump.
B)A defective fuel control valve.
C)A leaking quill tube connection.
D)A defective pressure-protection valve.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
16
Technician A says that faster-responding piezoelectric injectors are best suited for use in light-duty CR engines. Technician B says that engine speeds of automotive diesel do not require the piezoelectric injector's higher number of injection events. Who is correct?

A)Technician A
B)Technician B
C)Both A and B
D)Neither A nor B
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
17
What typically happens to the length of the pulse width to the electronic fuel control valve (FCV) valve when fuel leaks from the high-pressure rail?

A)It remains the same.
B)It increases.
C)It decreases.
D)It increases, the suddenly decreases.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
18
While two technicians are discussing the purpose of a second electrical control valve, which regulates fuel volume supplied to the inlet of the high-pressure pump, Technician A says the VCV helps reduce fuel consumption. Technician B says the VCV is needed to reduce emissions. Who is correct?

A)Technician A
B)Technician B
C)Both A and B
D)Neither A nor B
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
19
Which of the following is the most likely cause of excessive fuel return from the cylinder head of a CR engine?

A)Excessive injection pressure.
B)A nozzle valve that is stuck closed.
C)Eroded or pitted ball valve seats.
D)A plugged inlet orifice in one or more injectors.
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
20
While performing a back leakage test for a second-generation Bosch CR fuel system, the fuel volume was measured to be above specification from the cylinder head. Technician A says the cause could be a leaking quill tube. Technician B says the cause could be one or more injectors with worn-out ball valve seats. Who is correct?

A)Technician A
B)Technician B
C)Both A and B
D)Neither A nor B
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
21
Current system pressures for heavy-duty CR injection operate as high as:

A)10,000-17,500 psi
B)13,000-25,500 psi
C)30,000-37,500 psi
D)40 000-47 500 psi"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
22
Technician A says that modern HPCR (High Pressure Common Rail) fuel pressurization occurs in concert with engine speed. Technician B says that regardless of engine rotational speed and load, HPCR fuel-injection pressure can be electronically controlled to provide the optimal pressure required. Who is right?

A)A only"
B)B only"
C)Both A and B
D)Neither A nor B"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
23
Which of the following fuel systems was developed by Bosch and used by Detroit Diesel's ACR (Amplified Common Rail) system?

A)HADIS (Hydraulically Amplified Diesel-Injection System)"
B)HPCR (High Pressure Common Rail)"
C)HEUI (hydraulically actuated electronic unit injection)
D)EUI (Electronic Unit Injection) system"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
24
Which of the following terms refers to a control system that multiplies a small mechanical force or movement into a much greater force or movement?

A)Accumulator"
B)Piston"
C)Piezo
D)Servo"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
25
Currently, the fastest production servo-hydraulic CR injector can produce ___ separate injection events during one combustion cycle.

A)4"
B)5"
C)6
D)9"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
26
Which of the following is an essential element of rate shaping, which refers to the quantity of fuel injected per degree of crankshaft rotation?

A)Nozzle-valve lift"
B)Fuel rate"
C)Rate curve
D)Injection rate"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
27
Two technicians are describing common rail fuel system operation. Technician A says that electronically regulating the pressure in the high-pressure pump permits injection pressures to vary with speed and load conditions. Technician B says that a common rail stores fuel pressurized to match optimal injection pressure for any given engine speed or load condition. Who is right?

A)A only"
B)B only"
C)Both A and B
D)Neither A nor B"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
28
How many main types of CR injectors are there?

A)1"
B)2"
C)3
D)4"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
29
Which of the following operations is NOT used by Bosch CR1 and CR2 injectors to inject fuel?

A)Electrical signal is removed from the magnetic solenoid"
B)Servo-hydraulic valve closes"
C)Drain hole from the pressure control chamber opens
D)Rail pressure lifts the nozzle valve"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
30
In which of the following Bosch CRS2 injector stages does closing the drain orifice cause fuel pressure to build in the pressure chamber, forcing the control rod against the nozzle valve?

A)Pre-injection"
B)Beginning of injection"
C)End of Injection
D)Post-injection"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
31
The CRS1, which had limited use in Europe only, uses a single spring to return the armature to a resting position, whereas the CRS2 uses:

A)two springs"
B)three springs"
C)four springs
D)five springs"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
32
Two technicians are discussing piezoceramic injectors. Technician A says that piezo technology involves replacing magnetic solenoids with high speed solenoids. Technician B says that piezoelectric crystals enable much faster injector response than do magnetic actuators. Who is right?

A)A only"
B)B only"
C)Both A and B
D)Neither A nor B"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
33
In which of the 3rd generation Bosch Piezo CRS3 injector stages is the nozzle valve hydraulically balanced with high-pressure fuel from the rail applied to the top and bottom of the nozzle valve?

A)Beginning of Injection"
B)Pre-injection"
C)End of Injection
D)Resting"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
34
Consider a hydraulically balanced needle valve used in a first- or second-generation Bosch common rail (CR) injector. How would a drain orifice that is much larger than the inlet orifice affect its functioning?

A)Slower nozzle lift than closing."
B)Faster nozzle opening than closing."
C)Failure of the nozzle valve to lift.
D)Failure of the nozzle valve to close."
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
35
What actuator technology is used with the Siemens VDO K16 pump?

A)Servo-hydraulic"
B)Spindle valve (amplified common rail (ACR))"
C)Ball valve
D)Piezoceramic"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
36
The Siemens CR injector uses a conventional six-hole nozzle valve that opens inward when the hydraulic balance of the nozzle valve is:

A)higher below the nozzle"
B)lower below the nozzle"
C)the same level as the nozzle
D)higher above the nozzle"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
37
Two technicians are explaining the Siemens injector operation. Technician A says that a piezoceramic actuator uses multiple stacked piezo crystal discs that expand longitudinally when electrically energized. Technician B says that fuel pressure in a chamber below the control piston regulates the movement of the control piston. Who is right?

A)A only"
B)B only"
C)Both A and B
D)Neither A nor B"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
38
At which stage of the Siemens injector operation does fuel pressurized by the high-pressure pump enter the fuel rail and is supplied to each injector fitting?

A)Post-Injection"
B)Pre-injection"
C)End of Injection
D)Injection"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
39
At which stage of the Siemens injector operation does the larger surface area above the control piston apply greater pressure than the force of the fuel against the nozzle-valve annulus?

A)Post-Injection"
B)Pre-injection"
C)End of Injection
D)Injection"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
40
At which stage of the Siemens injector operation does spring pressure close the mushroom valve, causing pressure to build in the control piston control chamber?

A)Post-Injection"
B)Pre-injection"
C)End of Injection
D)Injection"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
41
Technician A says that during the end of injection stage, the pressure in the control chamber forces the control piston downward against the nozzle valve, seating the nozzle valve and ending injection. Technician B says that the ECM de-energizes the piezoceramic actuator to cause a rapid return of the actuator to a resting position during the end of injection phase. Who is right?

A)A only"
B)B only"
C)Both A and B
D)Neither A nor B"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
42
Delphi claims the system can generate _____ reduction in emissions.

A)35% to 40%"
B)25% to 30%"
C)15% to 20%
D)45% to 50%"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
43
Injector adaptation to compensate for wear and deterioration is performed by an algorithm called:

A)speed pilot control (SPC)"
B)accelerometer pump control"
C)spindle valve (amplified common rail (ACR)
D)accelerometer pilot control"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
44
Two technicians are describing the Delphi Multec injector. Technician A says that the spindle valve used by Delphi nozzles is a servo-hydraulic actuator that uses the principles of hydraulic balance to rapidly open and close. Technician B says that the control valve also regulates the operation of a hydraulically balanced nozzle valve. Who is right?

A)A only"
B)B only"
C)Both A and B
D)Neither A nor B"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
45
The spindle valve used by Delphi nozzles is a ____ type of actuator that uses principles of hydraulic balance to open and close rapidly.

A)servo-hydraulic"
B)spindle valve (amplified common rail (ACR))"
C)ball valve
D)piezoceramic"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
46
The electric current supplied to Delphi's Multec solenoid CR injectors is at:

A)12 volts"
B)24 volts"
C)36 volts
D)112 volts"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
47
Each Delphi injector contains (a) laser printed:

A)dot matrix code"
B)pump compensation codes"
C)injector control codes
D)pump control codes"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
48
While two technicians are discussing the purpose of a second electrical control valve, which regulates fuel volume supplied to the inlet of the high-pressure pump, Technician A says the VCV helps reduce fuel consumption. Technician B says the VCV is needed to reduce emissions. Who is correct?

A)Technician A"
B)Technician B"
C)Both A and B
D)Neither A nor B"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
49
To reduce parasitic power losses produced by pumping fuel needlessly and to keep fuel temperatures low, pumps now use:

A)outlet pressure metering"
B)inlet pressure metering"
C)outlet volume metering
D)inlet volume metering"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
50
An electronically controlled fuel pressure regulator valve that varies pump _____ as commanded by the ECM regulates fuel supplied to the pump and maximum pump.

A)output pressure"
B)inlet pressure"
C)outlet volume
D)inlet volume"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
51
Which of the following is required for V engines to synchronize engine firing order with pump strokes?

A)1-piston pumps"
B)2-piston pumps"
C)4-piston pumps
D)8-piston pumps"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
52
Two technicians are describing pressure control components of common rail fuel. Technician A says if the high-pressure pump is removed, timing marks on the pump gear and camshaft gear are used to correctly time components during reinstallation. Technician B says that late-model high-pressure pumps are often timed so the peak pressure pulses are phased with the injection events. Who is right?

A)A only"
B)B only"
C)Both A and B
D)Neither A nor B"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
53
To which generation does the high-pressure pump that Bosch purchased from Fiat in the mid-1990s belong, which can develop pressure up to 19,845 psi and was used in the Unijet System?

A)Gen I"
B)Gen II"
C)Gen III
D)Gen IV"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
54
At what ratio to engine speed is the high-pressure CP-3 pump driven?

A)1:1"
B)2:1"
C)½ :1
D)4:1"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
55
While performing a back leakage test for a second-generation Bosch CR fuel system, the fuel volume was measured to be above specification from the cylinder head. Technician A says the cause could be a leaking quill tube. Technician B says the cause could be one or more injectors with worn-out ball valve seats. Who is correct?

A)Technician A"
B)Technician B"
C)Both A and B
D)Neither A nor B"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
56
Which of the following is NOT a strategy that can be used to identify faults on common rail systems?

A)Note the fuel mass"
B)Time the injection"
C)Control the fuel balance
D)Check the battery voltage"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
57
To monitor and maintain the emissions levels to their current standard, what legislation requires manufacturers to detect any potential malfunction that could cause emissions to rise above legislated standards?

A)OBDI"
B)OBDII"
C)OBDIII
D)OBDIV"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
58
Which of the following will cause an injector to leak or to stay open and inject fuel continuously?

A)Defective rail pressure sensor"
B)Fuel leak"
C)Defective high pressure pump
D)Worn eroded or dirty ball seat"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
59
Which one of the following is NOT a fuel return flow that can be measured to identify the faulty component?

A)Injector fuel return"
B)High-pressure pump return"
C)High-pressure relief valve return
D)Secondary filter return"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
60
Two technicians are describing measuring injector back leakage (method 1). Technician A says that you start and run the engine at idle, and for 5 minutes, measure and record the volume of fuel accumulating in the graduated cylinders. Technician B says that generally, a defective injector will flow three times the minimum return rate. Who is right?

A)A only"
B)B only"
C)Both A and B
D)Neither A nor B"
Unlock Deck
Unlock for access to all 60 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 60 flashcards in this deck.