Deck 35: Electrical Wiring, Connector Terminal Repair

Full screen (f)
exit full mode
Question
What is the reason for using gold and platinum coated terminals in connectors in chassis electronic wiring?

A) minimize voltage drops
B) high resistance
C) increased profit margins
D) ease of assembly
Use Space or
up arrow
down arrow
to flip the card.
Question
When assembling a typical weatherproof connector, what do the wire core wings contact?

A) insulation
B) bared wire
C) terminal guide
D) connector seal
Question
Before crimping a new terminal on a typical weatherproof connector assembly, which of the following should be done FIRST?

A) lock the terminal into the connector
B) bend the locking tang outward
C) force the locking tang flush
D) push the wire through the connector block
Question
When required to make butt connections on multiple wires within a harness, what should be done to avoid a bulge at the connection junctions?

A) use aluminum crimp connectors
B) hammer the connections flat
C) stagger the butt joints
D) use high tension shrink wrap
Question
What are the terminal contacts inserted to when assembling in a Deutsch type, barrel connector?

A) holding grommet
B) connector ports
C) terminal holes
D) setting gauge
Question
When soldering splice connectors, what type of solder should be used?

A) silver solder
B) pure lead solder
C) rosin core solder
D) pasted flux solder
Question
When sealing a butt splice with heat shrink conduit, what should be used to heat the conduit?

A) oxy-acetylene torch
B) propane torch
C) boiling water
D) heat gun
Question
Which of the following soldering methods is recommended when repairing wiring in electronic engine wiring harnesses?

A) use soldering gun to apply heat to the wire, then apply solder to the wire
B) use soldering gun to melt solder, then drizzle onto wire.
C) use a propane torch to heat wire, then apply solder
D) use a heat gun to heat wire, then apply solder to terminal
Question
If a multistrand copper cable has deteriorated so that only 10% of its strands are intact, what would you conclude after testing the cable with an ohmmeter either side of the deteriorated section?

A) Resistance was 10% specified value
B) Cable had failed
C) Resistance was 90% of specified value
D) Cable was OK
Question
In a standard SAE relay, which two terminals are used to energize the coil circuit?

A) 30 and 87a
B) 87a and 87
C) 85 and 86
D) 86 and 87
Question
When considering at the codes used for standard SAE relay assignments, which of the codes below correctly correlate the old and new SAE assignments?

A) 87 and 5
B) 87a and 3
C) 85 and 86
D) 85 and 4
Question
Technician A says that in a standard SAE relay, the common terminal assignment is identified by the numeric code 3. Technician B says that in a standard SAE relay, the control coil terminals are identified by numeric codes 4 and 5. Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Question
Which of the following letter designations identifies SAE wiring sectors that handle the engine/fuel control and management circuits?

A) A
B) C
C) E
D) M
Question
Technician A says that in chassis wiring that observes the new SAE wiring standards, any white wire with an orange tracer indicates a protected circuit. Technician B says that over 100 different colors identify different wires used in the new SAE wiring standards. Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Question
In chassis wiring that observes the new SAE wiring standards, what is indicated by a gray wire?

A) Unprotected circuit
B) Protected circuit
C) Chassis ground
D) CAN Bus Lo
Question
Technician A says that each wire used in trucks that comply with the new SAE chassis wiring standards must be identified by a alpha-numeric code. Technician B says that the new SAE chassis wiring standards require that each wire be identified by codes that appear printed every 10 cm apart. Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Question
Which of the following is a means of 'protecting' a circuit so that it would be coded grey using SAE wiring protocols?

A) fuse
B) cycling circuit breakers
C) non-cycling circuit breakers
D) all of the above
Question
When a non-cycling circuit breaker trips open, specifically what prevents the armature from closing when it cools?

A) heat from an integral resistor
B) residual heat from the current overload
C) pressure from a latching spring
D) control coil
Question
Technician A says that four-terminal relays are commonly used in truck wiring today. Technician B says that a four-terminal relay eliminates the normally-closed (NC) option used on a five-terminal relay. Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Question
Technician A says that most OEMs today no longer produce hard-copy wiring schematics. Technician B says that virtual schematics are easier to use because they are often interactive. Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Question
Where would you be likely to find virtual wiring schematics?

A) OEM SIS
B) generic diagnostic software
C) DVD-ROM
D) service manual
Question
Which of the following would be more likely to occur in a truck using SAE wiring codes, if you attempted to connect a gray colored wire with a red colored wire?

A) blown fuse
B) tripped cycling circuit breaker
C) nothing
D) a fire
Question
Technician A says that in a truck using virtual circuit protection devices, the circuit is tripped open when logic analysis of the circuit conditions determines that it is overloaded. Technician B says that when a virtual fuse trips open, it must be replaced by another using the identical OEM part number. Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Question
You are testing an energized solenoid in a series circuit using a voltmeter and identify the following circuit conditions:
Voltage measured from solenoid positive terminal to chassis ground: 12.6 V-DC
Voltage measured from solenoid negative terminal to chassis ground: 4.0 V-DC
Voltage dropped across solenoid positive to negative terminals: 8.5 volts
Where is the problem in the circuit likely to be found?

A) On the positive side of the load
B) On the negative side of the load
C) The load (solenoid)
D) No circuit problem based on this data
Question
You are testing a running motor in a series circuit using a voltmeter and identify the following circuit conditions:
Voltage measured from motor positive terminal to chassis ground: 8.6 V-DC
Voltage measured from motor negative terminal to chassis ground: 0 V-DC
Voltage dropped across motor positive and negative terminals: 8.6 volts
Where is the problem in the circuit likely to be found?

A) On the positive side of the load
B) On the negative side of the load
C) The load (motor)
D) No circuit problem based on this data
Question
You are testing an energized solenoid in a series circuit using a voltmeter and identify the following circuit conditions:
Voltage measured from solenoid positive terminal to chassis ground: 12.6 V-DC
Voltage measured from solenoid negative terminal to chassis ground: 0.1 V-DC
Voltage dropped across solenoid positive to negative terminals: 12.5 volts
Where is the problem in the circuit likely to be found?

A) On positive side of load
B) On negative side of load
C) The load (solenoid)
D) No circuit problem based on this data
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/26
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 35: Electrical Wiring, Connector Terminal Repair
1
What is the reason for using gold and platinum coated terminals in connectors in chassis electronic wiring?

A) minimize voltage drops
B) high resistance
C) increased profit margins
D) ease of assembly
minimize voltage drops
2
When assembling a typical weatherproof connector, what do the wire core wings contact?

A) insulation
B) bared wire
C) terminal guide
D) connector seal
bared wire
3
Before crimping a new terminal on a typical weatherproof connector assembly, which of the following should be done FIRST?

A) lock the terminal into the connector
B) bend the locking tang outward
C) force the locking tang flush
D) push the wire through the connector block
push the wire through the connector block
4
When required to make butt connections on multiple wires within a harness, what should be done to avoid a bulge at the connection junctions?

A) use aluminum crimp connectors
B) hammer the connections flat
C) stagger the butt joints
D) use high tension shrink wrap
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
5
What are the terminal contacts inserted to when assembling in a Deutsch type, barrel connector?

A) holding grommet
B) connector ports
C) terminal holes
D) setting gauge
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
6
When soldering splice connectors, what type of solder should be used?

A) silver solder
B) pure lead solder
C) rosin core solder
D) pasted flux solder
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
7
When sealing a butt splice with heat shrink conduit, what should be used to heat the conduit?

A) oxy-acetylene torch
B) propane torch
C) boiling water
D) heat gun
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
8
Which of the following soldering methods is recommended when repairing wiring in electronic engine wiring harnesses?

A) use soldering gun to apply heat to the wire, then apply solder to the wire
B) use soldering gun to melt solder, then drizzle onto wire.
C) use a propane torch to heat wire, then apply solder
D) use a heat gun to heat wire, then apply solder to terminal
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
9
If a multistrand copper cable has deteriorated so that only 10% of its strands are intact, what would you conclude after testing the cable with an ohmmeter either side of the deteriorated section?

A) Resistance was 10% specified value
B) Cable had failed
C) Resistance was 90% of specified value
D) Cable was OK
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
10
In a standard SAE relay, which two terminals are used to energize the coil circuit?

A) 30 and 87a
B) 87a and 87
C) 85 and 86
D) 86 and 87
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
11
When considering at the codes used for standard SAE relay assignments, which of the codes below correctly correlate the old and new SAE assignments?

A) 87 and 5
B) 87a and 3
C) 85 and 86
D) 85 and 4
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
12
Technician A says that in a standard SAE relay, the common terminal assignment is identified by the numeric code 3. Technician B says that in a standard SAE relay, the control coil terminals are identified by numeric codes 4 and 5. Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
13
Which of the following letter designations identifies SAE wiring sectors that handle the engine/fuel control and management circuits?

A) A
B) C
C) E
D) M
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
14
Technician A says that in chassis wiring that observes the new SAE wiring standards, any white wire with an orange tracer indicates a protected circuit. Technician B says that over 100 different colors identify different wires used in the new SAE wiring standards. Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
15
In chassis wiring that observes the new SAE wiring standards, what is indicated by a gray wire?

A) Unprotected circuit
B) Protected circuit
C) Chassis ground
D) CAN Bus Lo
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
16
Technician A says that each wire used in trucks that comply with the new SAE chassis wiring standards must be identified by a alpha-numeric code. Technician B says that the new SAE chassis wiring standards require that each wire be identified by codes that appear printed every 10 cm apart. Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
17
Which of the following is a means of 'protecting' a circuit so that it would be coded grey using SAE wiring protocols?

A) fuse
B) cycling circuit breakers
C) non-cycling circuit breakers
D) all of the above
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
18
When a non-cycling circuit breaker trips open, specifically what prevents the armature from closing when it cools?

A) heat from an integral resistor
B) residual heat from the current overload
C) pressure from a latching spring
D) control coil
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
19
Technician A says that four-terminal relays are commonly used in truck wiring today. Technician B says that a four-terminal relay eliminates the normally-closed (NC) option used on a five-terminal relay. Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
20
Technician A says that most OEMs today no longer produce hard-copy wiring schematics. Technician B says that virtual schematics are easier to use because they are often interactive. Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
21
Where would you be likely to find virtual wiring schematics?

A) OEM SIS
B) generic diagnostic software
C) DVD-ROM
D) service manual
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
22
Which of the following would be more likely to occur in a truck using SAE wiring codes, if you attempted to connect a gray colored wire with a red colored wire?

A) blown fuse
B) tripped cycling circuit breaker
C) nothing
D) a fire
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
23
Technician A says that in a truck using virtual circuit protection devices, the circuit is tripped open when logic analysis of the circuit conditions determines that it is overloaded. Technician B says that when a virtual fuse trips open, it must be replaced by another using the identical OEM part number. Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
24
You are testing an energized solenoid in a series circuit using a voltmeter and identify the following circuit conditions:
Voltage measured from solenoid positive terminal to chassis ground: 12.6 V-DC
Voltage measured from solenoid negative terminal to chassis ground: 4.0 V-DC
Voltage dropped across solenoid positive to negative terminals: 8.5 volts
Where is the problem in the circuit likely to be found?

A) On the positive side of the load
B) On the negative side of the load
C) The load (solenoid)
D) No circuit problem based on this data
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
25
You are testing a running motor in a series circuit using a voltmeter and identify the following circuit conditions:
Voltage measured from motor positive terminal to chassis ground: 8.6 V-DC
Voltage measured from motor negative terminal to chassis ground: 0 V-DC
Voltage dropped across motor positive and negative terminals: 8.6 volts
Where is the problem in the circuit likely to be found?

A) On the positive side of the load
B) On the negative side of the load
C) The load (motor)
D) No circuit problem based on this data
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
26
You are testing an energized solenoid in a series circuit using a voltmeter and identify the following circuit conditions:
Voltage measured from solenoid positive terminal to chassis ground: 12.6 V-DC
Voltage measured from solenoid negative terminal to chassis ground: 0.1 V-DC
Voltage dropped across solenoid positive to negative terminals: 12.5 volts
Where is the problem in the circuit likely to be found?

A) On positive side of load
B) On negative side of load
C) The load (solenoid)
D) No circuit problem based on this data
Unlock Deck
Unlock for access to all 26 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 26 flashcards in this deck.