Question 1
Multiple Choice
Knife switches rated more than ____, and at over 1000 amperes at 251 to 1000 volts, shall be used only as isolating switches and shall not be opened under load.
Question 2
Multiple Choice
Means shall be provided to disconnect all conductors in a building (or other structure) from the ____.
Question 3
Multiple Choice
The combined length of one primary plus one secondary conductor (excluding any portion of the primary conductor protected at its ampacity) shall not exceed ____.
Question 4
Multiple Choice
Cable tray systems should be ____.
Question 5
Multiple Choice
Barriers are required in all service-entrance motor-control centers to ____ and terminals from the remainder of the motor-control center.
Question 6
Multiple Choice
A transformer's primary conductors shall have an ampacity at least ____ of the feeder conductors' overcurrent device rating.
Question 7
Multiple Choice
If the ungrounded supply conductors are larger than 1100 kcmil copper or 1750 kcmil aluminum, the supply-side bonding jumper shall have an area not less than ____ percent of the area of the largest ungrounded supply conductor or equivalent area for parallel supply conductors.
Question 8
Multiple Choice
Cartridge fuse and fuseholder overcurrent protection provisions are located in ____.
Question 9
Multiple Choice
A transformer vault door must be ____.
Question 10
Multiple Choice
____ branch circuits shall be protected at the motor nameplate current rating.
Question 11
Multiple Choice
Overload is defined as operation of equipment in excess of normal, full-load rating, or of a conductor ____ that, when it persists for a sufficient length of time, would cause damage or dangerous overheating.
Question 12
Multiple Choice
To calculate the ampacity of conductors supplying several motors (feeder conductors) , multiply the largest motor full-load current (FLC) rating by ____% and add the FLC ratings of all other motors (or loads) in the group.
Question 13
Multiple Choice
Motor circuits rated 1000 volts, nominal, or less, shall have a disconnecting means with an ampere rating of at least ____% of the motor's full-load current rating.
Question 14
Multiple Choice
Wherever such an arrangement is practicable, transformer vaults shall be located so that ____.
Question 15
Multiple Choice
A tap conductor is a ____ that exceeds the value permitted for similar conductors protected as otherwise described in 240.4.
Question 16
Multiple Choice
A ____ is the minimum size allowed if the overcurrent protection on the tap conductor's line side is 600 amperes.
Question 17
Multiple Choice
The tap conductor's ampacity shall not be less than the ____ on the circuits it supplies.
Question 18
Multiple Choice
Where an orderly shutdown is required to minimize the personnel/equipment hazard(s) , a system of coordination based on the following two conditions is permitted: (1) coordinated short-circuit protection and (2) ____.