Services
Discover
Homeschooling
Ask a Question
Log in
Sign up
Filters
Done
Question type:
Essay
Multiple Choice
Short Answer
True False
Matching
Topic
Engineering
Study Set
Power System Analysis
Quiz 1: Fundamentals
Path 4
Access For Free
Share
All types
Filters
Study Flashcards
Question 1
Essay
The instantaneous voltage across a circuit is
v
(
t
)
=
678.8
sin
v(t)=678.8 \sin
v
(
t
)
=
678.8
sin
(
ω
t
−
1
5
∘
)
\left(\omega t-15^{\circ}\right)
(
ω
t
−
1
5
∘
)
volts, and the instantaneous current entering the positive terminal if the circuit element is
i
(
t
)
=
200
cos
(
ω
t
−
5
∘
)
i(t)=200 \cos \left(\omega t-5^{\circ}\right)
i
(
t
)
=
200
cos
(
ω
t
−
5
∘
)
A. For these circuit elements, calculate (a) the instantaneous power absorbed, (b) the real power (state whether it is delivered or absorbed), (c) the reactive power (state whether delivered or absorbed), (d) the power factor (state whether lagging or leading).
Question 2
Essay
The voltage
v
(
t
)
=
678.8
cos
(
ω
t
+
4
5
∘
)
v(t)=678.8 \cos \left(\omega t+45^{\circ}\right)
v
(
t
)
=
678.8
cos
(
ω
t
+
4
5
∘
)
volts is applied to a load consisting of a
10
−
W
10-\mathrm{W}
10
−
W
resistor in parallel with a capacitive reactance
X
C
=
25
W
\mathrm{X}_{\mathrm{C}}=25 \mathrm{~W}
X
C
=
25
W
. Calculate (a) the instantaneous power absorbed by the resistor, (b) the instantaneous power absorbed by the capacitor, (c) the real power absorbed by the resistor, (d) the reactive power delivered by the capacitor, (e) the load power factor.
Question 3
Essay
if the resistor and capacitor are connected in series.
Question 4
Essay
Consider a single-phase loadwith an applied voltage
v
(
t
)
=
150
2
cos
(
ω
t
+
1
0
∘
)
v(t)=150 \sqrt{2} \cos \left(\omega t+10^{\circ}\right)
v
(
t
)
=
150
2
cos
(
ω
t
+
1
0
∘
)
volts and load current
i
(
t
)
=
5
2
cos
(
ω
t
−
5
0
∘
)
A
i(t)=5 \sqrt{2} \cos \left(\omega t-50^{\circ}\right) \mathrm{A}
i
(
t
)
=
5
2
cos
(
ω
t
−
5
0
∘
)
A
. (a) Determinethe power triangle. (b) Find the power factor and specify whether it islagging or leading. (c) Calculate the reactive power supplied by capacitors in parallel with the load that correctthe power factor to 0.9 lagging.
Question 5
Essay
A circuit consists of two impedances,
Z
1
=
20
∠
3
0
∘
Ω
Z_{1}=20 \angle 30^{\circ} \Omega
Z
1
=
20∠3
0
∘
Ω
and
Z
2
=
14.14
∠
−
4
5
∘
Ω
Z_{2}=14.14 \angle-45^{\circ} \Omega
Z
2
=
14.14∠
−
4
5
∘
Ω
, in parallel, supplied by a source voltage
V
=
100
∠
6
0
∘
V=100 \angle 60^{\circ}
V
=
100∠6
0
∘
volts. Determine the power triangle for each of the impedances and for the source.
Question 6
Essay
An industrial plant consisting primarily of induction motor loads absorbs
1000
k
W
1000 \mathrm{~kW}
1000
kW
at 0.7 power factor lagging. (a) Compute the required kVA rating of a shunt capacitor to improve the power factor to 0.9 lagging. (b) Calculate the resulting power factor if a synchronous motor rated
1000
h
p
1000 \mathrm{hp}
1000
hp
with
90
%
90 \%
90%
efficiency operating at rated load and at unity power factor is added to the plant instead of the capacitor. Assume constant voltage.
(
1
h
p
=
0.746
k
W
)
(1 \mathrm{hp}=0.746 \mathrm{~kW})
(
1
hp
=
0.746
kW
)
Question 7
Essay
The real power delivered by a source to two impedances,
Z
1
\mathrm{Z}_{1}
Z
1
=
3
+
j
5
W
=3+j 5 \mathrm{~W}
=
3
+
j
5
W
and
Z
2
=
10
W
\mathrm{Z}_{2}=10 \mathrm{~W}
Z
2
=
10
W
, connected in parallel, is
2000
W
2000 \mathrm{~W}
2000
W
. Determine (a) the real power absorbed by each of the impedances and (b) the source current.
Question 8
Essay
A single-phase source has a terminal voltage
V
=
120
∠
0
∘
V=120 \angle 0^{\circ}
V
=
120∠
0
∘
volts and a current
I
=
25
∠
3
0
∘
A
I=25 \angle 30^{\circ} \mathrm{A}
I
=
25∠3
0
∘
A
, which leaves the positive terminal of the source. Determine the real and reactive power, and state whether the source is delivering or absorbing each.
Question 9
Essay
A three-phase 25-kVA, 208-V, 60-Hz alternator, operating under balanced steady-state conditions, supplies a line current of 20 A per phase at a 0.8 lagging power factor and at rated voltage. Determine the power triangle for this operating condition.