Deck 13: The Electric Service

Full screen (f)
exit full mode
Question
GFPE monitors are designed to sense faults only.

A)phase-to-phase
B)phase-to-ground
C)3-phase
D)phase-to-neutral
Use Space or
up arrow
down arrow
to flip the card.
Question
GFCI protection can be attained using GFCI circuit breakers or GFCI .

A)switchboards
B)monitors
C)receptacles
D)fuses
Question
The connection scheme has the advantage of being able to provide either 3-phase or 3-phase and single-phase power using only two transformers.

A)three-wire delta
B)4-wire wye
C)open delta
D)single-phase
Question
When is ground-fault protection of equipment not required?
Question
NEC 110.16 has a requirement for placing a notice on certain equipment to warn qualified persons of the serious hazard of flash events.

A)arc
B)current
C)lightning
D)circuit
Question
The temperatures of an electrical arc, such as might occur on a 480/277-volt solidly grounded, wye-connected system, are .

A)at the boiling point of water
B)not hot enough to melt metals
C)safe for humans
D)hotter than the surface of the sun
Question
Dry-type transformers are widely used because they are than comparably rated liquid-filled transformers.

A)better dielectrics
B)better conductors
C)heavier in weight
D)lighter in weight
Question
What liquid was used in the past in liquid-filled transformers? Is it still in use?
Question
When and how does primary high-voltage metering take place?
Question
Throughout this country, and for that matter, throughout the world, is(are) the common reference point for all electrical systems.

A)the atmosphere
B)a standard metal plate
C)the earth
D)individual building walls
Question
occur when an ungrounded "hot" conductor comes in contact with a grounded surface or grounded equipment.

A)Circuit breakings
B)Ground faults
C)Groundings
D)Arc blasts
Question
What is an effective ground-fault current path?
Question
What are the advantages of proper bonding and grounding?
Question
NEC 230.71 permits not more than disconnects to serve as the building disconnecting means.

A)6
B)10
C)14
D)18
Question
Utilities make up the connections on the line side and load side of their transformers according to the requirements.

A)NFPA
B)NESC
C)TEK
D)UL
Question
The two basic methods of metering are primary high-voltage metering and .

A)intermediate-voltage metering
B)pulsed metering
C)secondary high-voltage metering
D)low-voltage metering
Question
NEC 250.64(C) states that grounding electrode conductors generally are not permitted to be .

A)cut
B)spliced
C)joined
D)integrated
Question
Today's liquid­filled transformers have their windings immersed in highly refined mineral oil (combustible), silicone fluid, edible seed oil-based dielectric coolant, or other acceptable nontoxic liquids that have properties.

A)high dielectric
B)high conductance
C)low dielectric
D)photoactive
Question
The is defined in NEC Article 100 as the point of connection between the facilities of the serving utility and the premises wiring.

A)open delta
B)singular phase
C)service point
D)transformer
Question
The lower the of the grounding path, the greater the ground-fault current.

A)length
B)elevation
C)magnetic permeability
D)impedance
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 13: The Electric Service
1
GFPE monitors are designed to sense faults only.

A)phase-to-phase
B)phase-to-ground
C)3-phase
D)phase-to-neutral
B
2
GFCI protection can be attained using GFCI circuit breakers or GFCI .

A)switchboards
B)monitors
C)receptacles
D)fuses
C
3
The connection scheme has the advantage of being able to provide either 3-phase or 3-phase and single-phase power using only two transformers.

A)three-wire delta
B)4-wire wye
C)open delta
D)single-phase
C
4
When is ground-fault protection of equipment not required?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
NEC 110.16 has a requirement for placing a notice on certain equipment to warn qualified persons of the serious hazard of flash events.

A)arc
B)current
C)lightning
D)circuit
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
The temperatures of an electrical arc, such as might occur on a 480/277-volt solidly grounded, wye-connected system, are .

A)at the boiling point of water
B)not hot enough to melt metals
C)safe for humans
D)hotter than the surface of the sun
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
Dry-type transformers are widely used because they are than comparably rated liquid-filled transformers.

A)better dielectrics
B)better conductors
C)heavier in weight
D)lighter in weight
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
What liquid was used in the past in liquid-filled transformers? Is it still in use?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
When and how does primary high-voltage metering take place?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
Throughout this country, and for that matter, throughout the world, is(are) the common reference point for all electrical systems.

A)the atmosphere
B)a standard metal plate
C)the earth
D)individual building walls
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
occur when an ungrounded "hot" conductor comes in contact with a grounded surface or grounded equipment.

A)Circuit breakings
B)Ground faults
C)Groundings
D)Arc blasts
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
What is an effective ground-fault current path?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
What are the advantages of proper bonding and grounding?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
NEC 230.71 permits not more than disconnects to serve as the building disconnecting means.

A)6
B)10
C)14
D)18
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
Utilities make up the connections on the line side and load side of their transformers according to the requirements.

A)NFPA
B)NESC
C)TEK
D)UL
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
The two basic methods of metering are primary high-voltage metering and .

A)intermediate-voltage metering
B)pulsed metering
C)secondary high-voltage metering
D)low-voltage metering
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
NEC 250.64(C) states that grounding electrode conductors generally are not permitted to be .

A)cut
B)spliced
C)joined
D)integrated
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
Today's liquid­filled transformers have their windings immersed in highly refined mineral oil (combustible), silicone fluid, edible seed oil-based dielectric coolant, or other acceptable nontoxic liquids that have properties.

A)high dielectric
B)high conductance
C)low dielectric
D)photoactive
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
The is defined in NEC Article 100 as the point of connection between the facilities of the serving utility and the premises wiring.

A)open delta
B)singular phase
C)service point
D)transformer
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
The lower the of the grounding path, the greater the ground-fault current.

A)length
B)elevation
C)magnetic permeability
D)impedance
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 20 flashcards in this deck.