Question 1
Multiple Choice
GFPE monitors are designed to sense faults only.
Question 2
Multiple Choice
GFCI protection can be attained using GFCI circuit breakers or GFCI .
Question 3
Multiple Choice
The connection scheme has the advantage of being able to provide either 3-phase or 3-phase and single-phase power using only two transformers.
Question 4
Essay
When is ground-fault protection of equipment not required?
Question 5
Multiple Choice
NEC 110.16 has a requirement for placing a notice on certain equipment to warn qualified persons of the serious hazard of flash events.
Question 6
Multiple Choice
The temperatures of an electrical arc, such as might occur on a 480/277-volt solidly grounded, wye-connected system, are .
Question 7
Multiple Choice
Dry-type transformers are widely used because they are than comparably rated liquid-filled transformers.
Question 8
Essay
What liquid was used in the past in liquid-filled transformers? Is it still in use?
Question 9
Essay
When and how does primary high-voltage metering take place?
Question 10
Multiple Choice
Throughout this country, and for that matter, throughout the world, is(are) the common reference point for all electrical systems.
Question 11
Multiple Choice
occur when an ungrounded "hot" conductor comes in contact with a grounded surface or grounded equipment.
Question 12
Essay
What is an effective ground-fault current path?
Question 13
Essay
What are the advantages of proper bonding and grounding?
Question 14
Multiple Choice
NEC 230.71 permits not more than disconnects to serve as the building disconnecting means.
Question 15
Multiple Choice
Utilities make up the connections on the line side and load side of their transformers according to the requirements.
Question 16
Multiple Choice
The two basic methods of metering are primary high-voltage metering and .
Question 17
Multiple Choice
NEC 250.64(C) states that grounding electrode conductors generally are not permitted to be .
Question 18
Multiple Choice
Today's liquidfilled transformers have their windings immersed in highly refined mineral oil (combustible) , silicone fluid, edible seed oil-based dielectric coolant, or other acceptable nontoxic liquids that have properties.