Question 61
Multiple Choice
Most large-volume nebulizers operate using:
Question 62
Multiple Choice
The Airlife large-volume nebulizer may be: I. used continuously II. used for cool aerosol therapy III. used for heated aerosol therapy IV. used for medication delivery
Question 63
Multiple Choice
You are troubleshooting the Vital Signs, Inc., Gas Injection Nebulizer (GIN) . You note the delivered F
I
O
2
is not correct. You should check: I. the air flowmeter setting II. the oxygen flowmeter setting III. the tubing for obstruction IV. the entrainment setting
Question 64
Multiple Choice
Use of a Diskhaler dry powder inhaler (DPI) requires:
Question 65
Multiple Choice
When a Vital Signs, Inc., Hi-Fi large-volume nebulizer with the oxygen flowmeter on the "flush" (maximum setting) is used, flow through the jet is:
Question 66
Multiple Choice
The Vital Signs, Inc., Gas Injection Nebulizer (GIN) may use: I. oxygen as a primary gas source II. air as a primary gas source III. oxygen as an injected gas source IV. air as an injected gas source
Question 67
Multiple Choice
The Vital Signs Hi-Fi nebulizer's reservoir connection is designed to use:
Question 68
Multiple Choice
Use of a Diskus dry powder inhaler (DPI) requires:
Question 69
Multiple Choice
The Vital Signs, Inc., Misty Ox Hi-Fi nebulizer may provide: I. F
I
O
2
levels from 0.28 to 0.65 II. F
I
O
2
levels from 0.60 to 0.96 III. flow rates from 12 to 42 L/min IV. flow rate from 42 to 77 L/min
Question 70
Multiple Choice
The reservoir connection of the Vital Signs, Inc., Gas Injection Nebulizer (GIN) is designed to use:
Question 71
Multiple Choice
The Vital Signs, Inc., Gas Injection Nebulizer (GIN) may be used to provide: I. cool aerosol II. heated aerosol III. high flow rates (up to 100 L/min) IV. high oxygen concentrations
Question 72
Multiple Choice
The Airlife large-volume nebulizer's reservoir fitting may use:
Question 73
Multiple Choice
You are troubleshooting a large-volume nebulizer, and the aerosol output has stopped. Which of the following should you check? I. the oxygen flowmeter setting II. the reservoir for liquid III. the capillary tube IV. the tubing for obstructions
Question 74
Multiple Choice
You are troubleshooting the Vital Signs, Inc., Gas Injection Nebulizer (GIN) . You note that aerosol output is low or absent. You should check: I. the flowmeter settings II. the reservoir for liquid III. the capillary tube IV. the tubing for obstructions
Question 75
Multiple Choice
When troubleshooting a Vital Signs, Inc., Hi-Fi large-volume nebulizer, you note the oxygen concentration to be too high. You should check: I. the entrainment setting II. the oxygen flowmeter setting III. the tubing for obstructions IV. the fittings and connections for tightness
Question 76
Multiple Choice
Large-volume nebulizers typically must be filled every:
Question 77
Multiple Choice
Prior to instructing a patient to use a dry powder inhaler (DPI) , you should: I. learn to assemble it II. practice with a placebo DPI III. read the package insert on its use IV. use a holding chamber with the DPI