Question 1
Multiple Choice
A(n) __________ is a plastic or fiber fitting designed to screw onto the ends of a conduit or cable connector to provide protection to the conductors.
Question 2
Multiple Choice
__________ is a common wiring method used to bring the electrical power from the point of attachment to the meter socket and then on to the main service equipment.
Question 3
True/False
When connecting sub-panel feeder conductors in the main panel, both the grounded neutral conductor and the grounding conductor are connected to the main panel grounded neutral bar.
Question 4
Multiple Choice
The NEC requirements for minimum burial depths are found in Table __________.
Question 5
Multiple Choice
The conductors that run overhead from the utility transformer to the residence are called the __________.
Question 6
Multiple Choice
The NEC provides the specifications for working space around electrical equipment in Article __________.
Question 7
Multiple Choice
When using service entrance cable for the run between the weatherhead and the meter socket, the cable must be supported within __________ of both the weatherhead and the meter socket.
Question 8
Multiple Choice
When installing an underground service, a warning tape must be installed at least __________ inches above the buried service entrance conductors.
Question 9
True/False
A porcelain standoff fitting is used to attach the service drop cable to the side of a house.
Question 10
Multiple Choice
When installing an overhead service, __________ feet of conductor should stick out of the weatherhead for the formation of a drip loop.
Question 11
Multiple Choice
According to the NEC, the working space in front of a service entrance panel in a residential wiring application must be at least 6.5' high, 30" wide, and extend at least __________ feet in front of the panel.
Question 12
True/False
Section 338.12(B)(2) does not allow USE to be used above ground, except where it emerges from the ground and terminates in a meter socket.
Question 13
True/False
In a sub-panel, the grounding bar and the neutral bar are electrically connected together so that the white grounded conductors and the bare or green grounding conductors can all terminate at the same location.