Question 1
Multiple Choice
During an initial verification three conditions must be verified, one of these conditions as stated in BS7671 is:
Question 2
Multiple Choice
A non statutory document which may be referred to during the inspection of an electrical installation is:
Question 3
Multiple Choice
A statutory document which may be referred to during initial verification is
Question 4
Multiple Choice
The purpose of an initial verification as described in GN3 is
Question 5
Multiple Choice
A test value which may be obtained by the use of an RCD tester would be
Question 6
Multiple Choice
In sequence the first three tests carried out on a ring circuit would be
Question 7
Multiple Choice
An insulation resistance test carried out on five circuits of an electrical installation provided the following results, 50MO, 39MO, 56MO, 83MO and 26MO. Calculate the expected resistance if all of the circuits were to be measured together in parallel
Question 8
Multiple Choice
A special location which may be connected to a TN-C-S system is
Question 9
Multiple Choice
The insulation resistance test voltage which may be applied to a circuit containing surge protection is
Question 10
Multiple Choice
The number of tests required when carrying out a resistance test on an earth electrode which is to be used with a generator is
Question 11
Multiple Choice
State one situation within a domestic installation which would require the installation of an RCD
Question 12
Multiple Choice
An earth electrode test is to be carried out using an earth electrode tester, if the electrode under test is to be inserted to a depth of 2.5m the minimum recommended distance for the test probe C2 is
Question 13
Multiple Choice
The On Site Guide states that T.T TN-S and TN-C-S systems have the following max Ze values
Question 14
Multiple Choice
Where BS 7671 show a protective device as having a maximum Zs value of 2.3O the maximum corrected value will be
Question 15
Multiple Choice
A BS EN 61008-1 RCD is to be installed on a farm to provide fire protection, The maximum I∆n rating for the device would be
Question 16
Multiple Choice
The maximum disconnection time permissible for a BS EN 61008-1 RCD used for fire protection is
Question 17
Multiple Choice
The maximum permitted disconnection time for a 20A radial circuit connected to a TN-S system is
Question 18
Multiple Choice
A circuit is which is 30 m long ins wired in copper conductors each of which have a resistance value of 7.41mΩ/m at 20 deg C. Calculate the expected voltage drop for this circuit if a load of 16 A is connected to it