Question 81
Multiple Choice
You are reviewing a building backbone design with a vertically aligned telecommunications room (TR) . In the spec you note in a footnote with details that the slots at one end of the telecommunications room (TR) must be flush with the floor and the sleeves provide at the end of the telecommunications room (TR) must also be flush. In your meeting with the electrical engineering firm that has provided the spec, you make the comment that according to best practices, the MINIMUM that slots and sleeves must extend above the finished floor are:
Question 82
Multiple Choice
You have been asked to design a backbone cable connecting two large campus buildings. Your pathways will include using conduits, maintenance holes, and one section of 100 m (328 ft) of direct buried optical fiber cable. Your choice of fiber optic cable type recommendation is a:
Question 83
Multiple Choice
You have been asked to project manage a fiber cable backbone installation. In the course of the installation, you notice the fiber cable with a 25 mm (1 in) outside diameter is being installed into a small TR, and the cable is being installed into a tight corner. Based on your knowledge of minimum bend radius requirements for fiber cable, you must ensure that the MINIMUM cable bend radius of _______________ is provided when the cable installation is completed.
Question 84
Multiple Choice
When reviewing a backbone distribution system within a building provided to you for standards compliance, you see that there are several cables with bridge taps built in. Which one of the following options is correct?
Question 85
Multiple Choice
Rack mounted hardware is installed in two standard sized racks or cabinets. Those sizes are:
Question 86
Multiple Choice
When designing a fiber backbone using cable with an armored sheath, a major consideration that you must address is:
Question 87
Multiple Choice
The decision regarding the number of optical fibers to install (fiber strand count) in a backbone depends largely on all of the following EXCEPT:
Question 88
Multiple Choice
Optical fiber all-dielectric cables have an additional advantage over ones containing a steel strength member. That advantage is:
Question 89
Multiple Choice
The maximum vertical rise is the distance over which the cable is vertically self-supporting. This distance is a function of the weight of the cable and the:
Question 90
Multiple Choice
In reviewing your client's network needs for today and 5 years into the future, you note their current specs call for a 1Gb/s network within a campus environment, with little or no possibility of any increased bandwidth demands until they move to their planned future site. The building is not large, and the cable lengths will not exceed 550 m (1804 ft) . Your recommendation for the fiber to be installed in the backbone is:
Question 91
Multiple Choice
When designing a campus distribution system involving small buildings with only one horizontal cross-connect (HC) [Floor distributor (FD) ] per building, you can eliminate the need for a(n) :