Question 101
Multiple Choice
The RECOMMENDED balanced twisted-pair cable for building backbone cabling consists of ________ round solid copper conductors with a nominal characteristic of 100 ohm.
Question 102
Multiple Choice
You are recommending to an architect the location within a telecommunications room for the placement of floor sleeves connecting to the telecommunications room directly below. Where should the sleeves be placed within the room?
Question 103
Multiple Choice
A building has a floor space of 16.7 m (55 ft) by 45 m (150 ft) with a common core measuring 9.17 m (30 ft) by 13.7 m (45 ft) . How many individual can be provided in the usable floor space?
Question 104
Multiple Choice
The MINIMUM recommended lighting requirement in a telecommunications room (TR) at the point of cable terminations is:
Question 105
Multiple Choice
In the customer's environment, an ITS designer should avoid the need for optical fiber field splicing by:
Question 106
Multiple Choice
You have been selected to do the telecommunications design on a new, single story building. The architect requires the size and location of the telecommunications rooms so their building design can proceed. From the items listed below (all of which are required for the design) , which one is the logical starting point in order to provide the architect with a size and location for the room?
Question 107
Multiple Choice
At a minimum, convenience receptacles in an ER or TR are to be located ________ AFF.
Question 108
Multiple Choice
On a survey of one of your client's buildings, you discover that one of the TRs, housing a considerable quantity of switching equipment, is at 25 degrees C (77 degrees F) with a relative humidity of 59 percent. This is considered to be:
Question 109
Multiple Choice
What is the MINIMUM ceiling height of a telecommunications room?
Question 110
Multiple Choice
The recommended ratio of patch panels to horizontal cable management panels is ________ RU of patch panel to ________ rack unit (RU) of horizontal cable management panel.
Question 111
Multiple Choice
The recommended MINIMUM number of conduits connecting two located on the same floor is:
Question 112
Multiple Choice
A campus backbone design linking two buildings requires that you install a high-fiber-count cable very quickly, using the conduit system provided. Cost is not so much an issue as urgency is to meet a service demand. Your first choice of fiber cable installation is to use:
Question 113
Multiple Choice
When allocating termination space for CAT 6 and optical fiber cables, it is recommended that additional space of up to ________ percent be considered for the routing of the cables and patch cords.
Question 114
Multiple Choice
One advantage of using preconnectorized jumpers and cables is:
Question 115
Multiple Choice
You are starting work on a new high school. The architect has provided you with a telecommunications room located between the kitchen cold store room and the automotive and welding shops. What should you do?
Question 116
Multiple Choice
You are working on the design of a new, large ER/TR that will contain many racks and data cabinets including a large UPS system. Your recommendation to the architect for room access from inside the building is:
Question 117
Multiple Choice
In a telecommunications room (TR) , the MINIMUM bottom edge height recommendation for mounting plywood on the wall is ________ above AFF.
Question 118
Multiple Choice
You are placing two 423 mm (19 in) relay racks with a 152 mm (6 in) vertical management panel on each end and a 12 in vertical cable management panel between the racks. The rack lineup begins against a wall in the room. What is the MINIMUM room size required?
Question 119
Multiple Choice
Which of the following types of conduit uses set screw couplings and connectors?
Question 120
Multiple Choice
"A single outlet utilizing a dedicated phase, neutral, and ground conductor" is the definition for which of the following?
showing 101 - 120 of 340